Gaetano Noè

Dr. Gaetano Noè

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2023 in Prosthesis
Verified
Journal Article
Open access
PDF file
GNGaetano Noè
Gaetano Noè
Andrea ToffoliAndrea Toffoli
Andrea Toffoli
EFEdoardo Foce
Edoardo Foce
GFGianfranco Di Febo
Gianfranco Di Febo
GCGianfranco Carnevale
Gianfranco Carnevale
EMEdoardo Manfredi
Edoardo Manfredi
This article aims to describe Vertical Edgeless Preparation (VEP), a full-crown vertical preparation technique initially introduced by the Porta Mascarella Group in the 1980s. The method is defined as “periodontally driven” because its main indication is teeth with a loss of periodontal attachment, and it aims to obtain healthier periodontal tissues. This work describes the step-by-step procedure for performing this prosthetic technique and its indications, contraindications, impression phases, temporary crown management, and its biological concept of periodontal dominance.

12 February 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
GNGaetano Noè
Gaetano Noè
Andrea ToffoliAndrea Toffoli
Andrea Toffoli
RBRoberto Bonfiglioli
Roberto Bonfiglioli
Guido Maria MacalusoGuido Maria Macaluso
Guido Maria Macaluso
EMEdoardo Manfredi
Edoardo Manfredi
Different techniques can be used to design and manufacture a full-arch, implant-supported prosthesis, and different materials can be chosen for its production, each with its advantages and limitations. One of the possibilities provided by digital tools is their ability to maintain low costs to give more patients the chance to choose this commonly expensive treatment. The present work aims to present a protocol for the realization of full-arch, implant-fixed complete dentures (IFCDs) in monolithic zirconia and titanium. When the analogic master model is obtained, it is scanned to perform the digital wax-up, and the two parts of the prosthesis—a bar in titanium and an aesthetic component in monolithic zirconia—are milled. The dental team must then verify the precision of the milled components on the master model, so that they can be cemented together and delivered to the patient. This technique offers different advantages, in terms of cost sustainability, minimal wear risk for the prosthesis and its antagonists, and ease of re-intervening in the case of complications. The main limitations of the technique may lie in the aesthetic needs of the patient, because of the relatively poor aesthetic performance of monolithic zirconia and the absence of a pink orthopedic component.

16 June 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
SLSoo-Young Lee
Soo-Young Lee
YCYOUNGJIN CHO
YOUNGJIN CHO
KNKwan-Tae Noh
Kwan-Tae Noh
OCOhkubo Chikahiro
Ohkubo Chikahiro
Marco CicciùMarco Cicciù
Marco Cicciù
Background: While dental implants have become a reliable solution for tooth loss, their long-term success is increasingly challenged by biological and technical complications such as impact fracture and peri-implantitis. These complications significantly impact implant longevity and patient satisfaction. Aim: This consensus conference aimed to identify and standardize clinical guidelines to prevent implant fractures and peri-implant diseases based on current evidence and expert opinions. Methods: A panel of 10 expert clinicians and researchers in prosthodontics participated in the Osstem Global Consensus Meeting. This paper focuses on the prosthetic division. A structured literature review was conducted, and evidence was synthesized to formulate consensus-based clinical recommendations. Participants answered structured questions and discussed discrepancies to achieve consensus. Results: The panel reached consensus on several key prosthetic risk factors, including (1) the role of biomechanical overload in implant fracture, (2) the impact of emergence profile design on peri-implant tissue stability, (3) the influence of implant positioning and connection geometry on marginal bone loss, and (4) the importance of occlusal scheme and restorative material selection, particularly in high-risk patients such as bruxers. Guidelines to prevent implant fracture and peri-implantitis were developed, addressing these factors with practical preventive strategies. Conclusions: Despite the limitations of narrative methodology and reliance on retrospective data and expert opinion, this consensus provides clinically relevant guidelines to aid in the prevention of mechanical failures and peri-implant diseases. The recommendations emphasize prosthetically driven planning, individualized risk assessment, and early intervention to support long-term implant success.

9 June 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
LSLee Soo-Young
Lee Soo-Young
YCYOUNGJIN CHO
YOUNGJIN CHO
KNKwantae Noh
Kwantae Noh
COChikahiro Ohkubo
Chikahiro Ohkubo
Marco CicciùMarco Cicciù
Marco Cicciù
Dental implants have become a cornerstone in restorative dentistry, offering effective solutions for tooth loss. However, their long-term success is often challenged by both biological and technical complications that can affect implant longevity and patient satisfaction. Biological complications, such as peri-implantitis, are characterized by inflammation and bone loss around the implant, leading to implant failure if left unmanaged. Peri-implant bone loss greater than 2 mm occurs in a significant portion of cases, with rates of 20.1% after five years and 40.3% after ten years. Technical complications, including screw fractures and prosthetic issues like chipping, also contribute to implant failure. The etiology of implant fractures is multifactorial, with biomechanical overload, material fatigue, implant design, and patient-related factors such as bruxism playing significant roles. Advances in implant materials and surface modifications aim to reduce these risks, yet cases of implant fractures continue to be reported, underlining the need for improved diagnostic, preventive, and management strategies. Peri-implant diseases, including peri-implantitis, are also on the rise, with patient-, surgical-, and prosthetic-related factors contributing to their development. To address these challenges, this narrative review synthesizes current evidence on the risk factors, prevention strategies, and management approaches for both biological and technical complications associated with dental implants. Through a systematic approach, a consensus was reached during the Osstem Global Consensus Meeting, providing updated guidelines to support clinicians in enhancing the long-term success of dental implants. These guidelines emphasize the prevention of mechanical failures, peri-implant diseases, and the importance of early detection and intervention.

18 February 2026 in Prosthesis
Verified
Journal Article
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
Francesco GrandeFrancesco Grande
Francesco Grande
GFGianluca Fortunato
Gianluca Fortunato
CCCarlotta Caccio'
Carlotta Caccio'
SLSoo-Young Lee
Soo-Young Lee
Gabriele CervinoGabriele Cervino
Gabriele Cervino
Aim: To develop clear, evidence-based, and standardized guidelines for the design, selection, and clinical use of implant abutments and prosthetic components in order to optimize the biological, mechanical, and esthetic performance of the implant supracrestal complex. Methods: A panel of 10 expert clinicians and researchers in prosthodontics participated in the Osstem Global Consensus Meeting. For the present consensus meeting, a scoping review was performed in advance and discussed among the participants. A comprehensive search of the literature was performed up to June 2025. Two reviewers (M.T. and F.G.) independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The evidence was synthesized and discussed by the panel of expert clinicians during the consensus meeting. After that, guidelines were developed using a 14-question questionnaire to formulate consensus-based clinical recommendations. The participants answered structured questions and discussed discrepancies to achieve a consensus. Results: The panel of expert clinicians reached a consensus on several prosthetic key points. Concave abutment profiles and emergence angles <30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, while zirconia provides superior esthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. The evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.

28 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Marco TallaricoMarco Tallarico
Marco Tallarico
Francesco GrandeFrancesco Grande
Francesco Grande
GFGianluca Fortunato
Gianluca Fortunato
CCCarlotta Caccio'
Carlotta Caccio'
SLSoo-Young Lee
Soo-Young Lee
Gabriele CervinoGabriele Cervino
Gabriele Cervino
Aim: To map current evidence and identify key factors influencing peri-implant tissue stability related to abutment configuration, design, materials, and prosthetic protocols in implant-supported fixed prostheses. Methods: A comprehensive search of PubMed and Scopus was performed up to June 2025, supplemented by manual searches. Human studies in English with ≥1 year of follow-up were included. Two reviewers independently conducted screening, data extraction, and quality assessment using the Newcastle–Ottawa Scale. The review was carried out at the Universities of Sassari and Ferrara in collaboration with the Osstem Global Consensus Meeting. Results: From 974 records, 46 studies were included: 33 randomized clinical trials, 9 cohort, 2 case-control, and 2 cross-sectional studies. Thirty-nine were rated as good quality and five as fair. Concave abutment profiles and emergence angles < 30° promoted peri-implant tissue stability, while convex designs and wider angles increased risks of bone loss and peri-implantitis. Titanium remains the reference abutment material in posterior sites, zirconia provides superior aesthetics anteriorly, and hybrid abutments balance strength and esthetics. Conclusions: Prosthetic design and abutment material selection critically affect peri-implant tissue stability and esthetic outcomes. Evidence supports screw-retained designs, platform switching, and the “one abutment–one time” approach for predictable long-term success.