Zvonimir Klaić

Dr. Zvonimir Klaić

Faculty of Electrical Engineering, Computer Science and Information Technology Osijek Kneza Trpimira 2b, 31000 Osijek, Croatia
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
MŽMatej Žnidarec
Matej Žnidarec
Zvonimir KlaićZvonimir Klaić
Zvonimir Klaić
Damir ŠljivacDamir Šljivac
Damir Šljivac
BDBoris Dumnic
Boris Dumnic
Expanding the number of photovoltaic (PV) systems integrated into a grid raises many concerns regarding protection, system safety, and power quality. In order to monitor the effects of the current harmonics generated by PV systems, this paper presents long-term current harmonic distortion prediction models. The proposed models use a multilayer perceptron neural network, a type of artificial neural network (ANN), with input parameters that are easy to measure in order to predict current harmonics. The models were trained with one-year worth of measurements of power quality at the point of common coupling of the PV system with the distribution network and the meteorological parameters measured at the test site. A total of six different models were developed, tested, and validated regarding a number of hidden layers and input parameters. The results show that the model with three input parameters and two hidden layers generates the best prediction performance.

5 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
MSMario Sipos
Mario Sipos
Zvonimir KlaićZvonimir Klaić
Zvonimir Klaić
Emmanuel Karlo NyarkoEmmanuel Karlo Nyarko
Emmanuel Karlo Nyarko
Krešimir FeketeKrešimir Fekete
Krešimir Fekete
Voltage dips represent a significant power quality problem. The main cause of voltage dips and short-term interruptions is an electrical short circuit that occurs in transmission or distribution networks. Faults in the power system are stochastic by nature and the main cause of voltage dips. As faults in the transmission system can affect more customers than faults in the distribution system, to reduce the number of dips, it is not enough to invest in a small part of the transmission or distribution system. Only targeted investment in the whole (or a large part of the) power system will reduce voltage dips. Therefore, monitoring parts of the power system is very important. The ideal solution would be to cover the entire system so that a power quality (PQ) monitor is installed on each bus, but this method is not economically justified. This paper presents an advanced method for determining the optimal location and the optimal number of voltage dip measuring devices. The proposed algorithm uses a monitor reach area matrix created by short-circuit simulations, and the coefficient of the exposed area. Single-phase and three-phase short circuits are simulated in DIgSILENT software on the IEEE 39 bus test system, using international standard IEC 60909. After determining the monitor reach area matrix of all potential monitor positions, the binary bat algorithm with a coefficient of the exposed area of the system bus is used to minimize the proposed objective function, i.e., to determine the optimal location and number of measuring devices. Performance of the binary bat algorithm is compared to the mixed-integer linear programming algorithm solved by using the GNU Linear Programming Kit (GLPK).

31 December 2018 in Eksploatacja i Niezawodność – Maintenance and Reliability
Verified
Journal Article
Closed access
SKSlaven Kaluđer
Slaven Kaluđer
Krešimir FeketeKrešimir Fekete
Krešimir Fekete
LJL. Jozsa
L. Jozsa
Zvonimir KlaićZvonimir Klaić
Zvonimir Klaić

23 October 2019 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
Zvonimir KlaićZvonimir Klaić
Zvonimir Klaić
GKGoran Knežević
Goran Knežević
MPMario Primorac
Mario Primorac
Danijel TopićDanijel Topić
Danijel Topić
Here, the impacts of biogas power plants and photovoltaic (PV) power plants on the power quality in the distribution network are presented and analysed. The biogas power plant's influence on the current harmonics is explored, as a synchronous generator powers the biogas power plant, and the PV plants are connected to the distribution network via the inverter. All the analyses are based on actual measurements that are performed in the last 10 years. Results of the analysis of these numerous measurements were a challenge for investigation how large share of PV systems in distribution network with non‐linear loads influence on THD from one side and how biogas power plant with a synchronous generator can improve THD from the other side. In order to investigate interaction of the biomass power plant and PV power plants on the power quality in distribution network, computer model was developed in DIgSILENT Power Factory where PV power plant and household were modelled as a source of current harmonic injections and biomass power plant was modelled as synchronous machine, as a source of voltage harmonics. Analysis of harmonic behaviour in different scenarios is examined through the performed simulations.

7 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSlaven Kaluđer
Slaven Kaluđer
Krešimir FeketeKrešimir Fekete
Krešimir Fekete
KČKristijan Čvek
Kristijan Čvek
Zvonimir KlaićZvonimir Klaić
Zvonimir Klaić
Active distribution grids that contain energy sources (so-called distributed generation or DG) are nowadays a reality. Besides the many benefits DGs bring to the distribution grid, some challenges are associated with their integration. Since there are DGs now in the distribution grid, the occurrence of islanding operation is possible. Since an islanding operation can be dangerous, it is necessary to have an effective method to detect it. In the last decade, scientists have made a great effort to develop and test various islanding detection methods (IDMs). Many approaches have been tested, and the methods based on computational intelligence (CI) have shown great potential. Among them, artificial neural networks (ANNs) gained most of the research attention. This paper focuses on ANN application for islanding detection. It gives an exhaustive review of the ANN types used for islanding detection, the types of input data, and their transformation to fit the ANNs. Furthermore, various applications based on specific input data, preprocessing types, different learning algorithms, real-time implementation, and various distribution models used for ANN are reviewed. This paper investigates the potential of ANNs to enhance islanding detection accuracy, reduce non-detection zone (NDZ), and contribute to an overall efficient detection method.

27 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
Krešimir FeketeKrešimir Fekete
Krešimir Fekete
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
Zvonimir KlaićZvonimir Klaić
Zvonimir Klaić
AAAna Androjić
Ana Androjić
Stochastic production from wind power plants imposes additional uncertainty in power system operation. It can cause problems in load and generation balancing in the power system and can also cause congestion in the transmission network. This paper deals with the problems of congestion in the transmission network, which are caused by the production of wind power plants. An optimization model for corrective congestion management is developed. Congestions are relieved by re-dispatching several cascaded hydropower plants. Optimization methodology covers the optimization period of one day divided into the 24 segments for each hour. The developed optimization methodology consists of two optimization stages. The objective of the first optimization stage is to obtain an optimal day-ahead dispatch plan of the hydropower plants that maximizes profit from selling energy to the day-ahead electricity market. If such a dispatch plan, together with the wind power plant production, causes congestion in the transmission network, the second optimization stage is started. The objective of the second optimization stage is the minimization of the re-dispatching of cascaded hydropower plants in order to avoid possible congestion. The concept of chance-constrained programming is used in order to consider uncertain wind power production. The first optimization stage is defined as a mixed-integer linear programming problem and the second optimization stage is defined as a quadratic programming (QP) problem, in combination with chance-constrained programming. The developed optimization model is tested and verified using the model of a real-life power system.