Cardiac fibers, as well as their local arrangement in laminar sheets, have a complex spatial variation of their orientation that has an important role in mechanical and electrical cardiac functions. In this paper, a statistical atlas of this cardiac fiber architecture is built for the first time using human datasets. This atlas provides an average description of the human cardiac fiber architecture along with its variability within the population. In this study, the population is composed of ten healthy human hearts whose cardiac fiber architecture is imaged ex vivo with DT-MRI acquisitions. The atlas construction is based on a computational framework that minimizes user interactions and combines most recent advances in image analysis: graph cuts for segmentation, symmetric log-domain diffeomorphic demons for registration, and log-Euclidean metric for diffusion tensor processing and statistical analysis. Results show that the helix angle of the average fiber orientation is highly correlated to the transmural depth and ranges from -41° on the epicardium to +66° on the endocardium. Moreover, we find that the fiber orientation dispersion across the population (13°) is lower than for the laminar sheets (31°). This study, based on human hearts, extends previous studies on other mammals with concurring conclusions and provides a description of the cardiac fiber architecture more specific to human and better suited for clinical applications. Indeed, this statistical atlas can help to improve the computational models used for radio-frequency ablation, cardiac resynchronization therapy, surgical ventricular restoration, or diagnosis and followups of heart diseases due to fiber architecture anomalies.
Purpose: To characterize certain aspects of the microscopic structures of cortical and trabecular bone by using Fourier x-ray scattering imaging. Materials and Methods: Protocols approved by the Na...
Purpose: To develop a technique for high resolution, four‐dimensional (4D), multiphase, steady‐state imaging with contrast enhancement (MUSIC) in children with complex congenital heart disease.Methods: Eight pediatric patients underwent cardiovascular MRI with controlled mechanical ventilation after ferumoxytol administration. Breath‐held contrast‐enhanced MRA (CE‐MRA) was performed during the first‐pass and delayed phases of ferumoxytol, followed by a respiratory gated, 4D MUSIC acquisition during the steady state distribution phase of ferumoxytol. The subjective image quality and image sharpness were evaluated. Assessment of ventricular volumes based on 4D MUSIC was compared with those based on multislice 2D cardiac cine MRI.Results: The 4D MUSIC technique provided cardiac‐phase‐resolved (65–95 ms temporal resolution) and higher spatial resolution (0.6–0.9 mm isotropic) images than previously achievable using first‐pass CE‐MRA or 2D cardiac cine. When compared with Ferumoxytol‐based first‐pass CE‐MRA, the 4D MUSIC provided sharper images and better definition of the coronary arteries, aortic root, myocardium, and pulmonary trunk (P < 0.05 for all). The ventricular volume measurements were in good agreement between 4D MUSIC and 2D cine (concordance correlation coefficient >0.95).Conclusion: The 4D MUSIC technique may represent a new paradigm in MR evaluation of cardiovascular anatomy and function in children with complex congenital heart disease. Magn Reson Med 74:1042–1049, 2015.
Objectives: Diffusion-weighted imaging (DWI) using low b-values permits imaging of intravoxel incoherent motion in tissues. However, low b-value DWI of the human heart has been considered too challenging because of additional signal loss due to physiological motion, which reduces both signal intensity and the signal-to-noise ratio (SNR). We address these signal loss concerns by analyzing cardiac motion during a heartbeat to determine the time-window during which cardiac bulk motion is minimal. Using this information to optimize the acquisition of DWI data and combining it with a dedicated image processing approach has enabled us to develop a novel low b-value diffusion-weighted cardiac magnetic resonance imaging approach, which significantly reduces intravoxel incoherent motion measurement bias introduced by motion. Materials and Methods: Simulations from displacement encoded motion data sets permitted the delineation of an optimal time-window with minimal cardiac motion. A number of single-shot repetitions of low b-value DWI cardiac magnetic resonance imaging data were acquired during this time-window under free-breathing conditions with bulk physiological motion corrected for by using nonrigid registration. Principal component analysis (PCA) was performed on the registered images to improve the SNR, and temporal maximum intensity projection (TMIP) was applied to recover signal intensity from time-fluctuant motion-induced signal loss. This PCATMIP method was validated with experimental data, and its benefits were evaluated in volunteers before being applied to patients. Results: Optimal time-window cardiac DWI in combination with PCATMIP postprocessing yielded significant benefits for signal recovery, contrast-to-noise ratio, and SNR in the presence of bulk motion for both numerical simulations and human volunteer studies. Analysis of mean apparent diffusion coefficient (ADC) maps showed homogeneous values among volunteers and good reproducibility between free-breathing and breath-hold acquisitions. The PCATMIP DWI approach also indicated its potential utility by detecting ADC variations in acute myocardial infarction patients. Conclusions: Studying cardiac motion may provide an appropriate strategy for minimizing the impact of bulk motion on cardiac DWI. Applying PCATMIP image processing improves low b-value DWI and enables reliable analysis of ADC in the myocardium. The use of a limited number of repetitions in a free-breathing mode also enables easier application in clinical conditions.
23 September 2017 in Magnetic Resonance in Medicine