16 June 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
BCBenjamin Clegg
Benjamin Clegg
SPSamuel Perry
Samuel Perry
EPEnrico De Pieri
Enrico De Pieri
ARAnthony C Redmond
Anthony C Redmond
SFStephen John Ferguson
Stephen John Ferguson
Andrew Robert BeadlingAndrew Robert Beadling
Andrew Robert Beadling
The current pre-clinical testing standards for total hip replacements (THRs), ISO standards, use simplified loading waveforms that do not fully replicate real-world biomechanics. These standards provide a benchmark of data that may not accurately predict in vivo wear, necessitating the evaluation of physiologically relevant loading conditions. Previous studies have incorporated activities of daily living (ADLs) such as walking, jogging and stair negotiation into wear simulations. However, these studies primarily used simplified adaptations that increased axial forces and applied accelerated sinusoidal waveforms, rather than fully replicating the complex kinematics experienced by THR patients. To address this gap, this study applied patient-derived ADL profiles—jogging and stair negotiation—using a three-station hip simulator, obtained through 3D motion analysis of total hip arthroplasty patients, processed via a musculoskeletal multibody modelling approach to derive realistic hip contact forces (HCFs). The results indicate that jogging significantly increased wear rates compared to the ISO walking gait waveform, with wear increasing from 15.24 ± 0.55 to 28.68 ± 0.87 mm3/Mc. Additionally, wear was highly sensitive to changes in lubricant protein concentration, with an increase from 17 g/L to 30 g/L reducing wear by over 60%. Contrary to predictive models, stair descent resulted in higher volumetric wear (8.62 ± 0.43 mm3/0.5 Mc) compared to stair ascent (4.15 ± 0.31 mm3/0.5 Mc), despite both profiles having similar peak torques. These findings underscore the limitations of current ISO standards in replicating physiologically relevant wear patterns. The application of patient-specific loading profiles highlights the need to integrate ADLs into pre-clinical testing protocols, ensuring a more accurate assessment of implant performance and longevity.

21 October 2026 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
BCBenjamin Clegg
Benjamin Clegg
JTJoanne L. Tipper
Joanne L. Tipper
NENazanin Emami
Nazanin Emami