Aleksandra Kamińska

Ms. Aleksandra Kamińska

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AKAleksandra Kamińska
Aleksandra Kamińska
MSMarcin Strąkowski
Marcin Strąkowski
JPJerzy Pluciński
Jerzy Pluciński
The main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has been expressed as a multiple beam interference. Therefore, the OCT system was modeled as a two-beam interferometer (e.g., Michelson), in which one beam propagates from the reference arm and the other comes from a Fabry–Pérot interferometer. As a consequence, the mathematical model consists of the main Michelson interferometer, in which the measuring arm represents the Fabry–Pérot interferometer. The parameters of the layer (or foil) are evaluated by analyzing the minimum value of the interference contrast. The model developed predicts the behavior of the thin layers made from different materials (with different refractive indexes) with different thickness and located at different depths. To verify the correctness of the proposed model, an experiment with a wedge cell has been carried out. The wedge cell was shifted across the scanning beam using a linear translation stage with a micrometer screw under the scanning head. The relationship between the thickness of the gap of the wedge cell and the OCT output signal is presented. For the additional verification of the proposed model, the results of the measurements of the thickness of the thin foil were compared with the theoretical results of the simulations. The film thickness was evaluated based on the calculated positions of the minimum value of interference contrast. A combination of the standard potentialities of OCT with the proposed approach to analyzing the signal produces new metrological possibilities. The method developed allows us to evaluate thickness under the resolution of the system and the location of the layer as well. This produces the possibility of measuring a layer which is covered by another layer. Moreover, it is possible to create a thickness map with high sensitivity to thickness changes. These experiments and simulations are the culmination of preliminary research for evaluating the potential of the proposed measurement method.

17 February 2017
Verified
Conference Paper
Closed access
PDF file
MSMarcin R. Strąkowski
Marcin R. Strąkowski
MGMaciej Glowacki
Maciej Glowacki
AKAleksandra Kamińska
Aleksandra Kamińska
MSMiroslaw Sawczak
Miroslaw Sawczak

30 September 2019 in Photonics Letters of Poland
Verified
Journal Article
Closed access
PDF file
KKKrzysztof Królewski
Krzysztof Królewski
AWAleksandra Wieloszyńska
Aleksandra Wieloszyńska
AKAleksandra Kamińska
Aleksandra Kamińska
KKKatarzyna Kardacz
Katarzyna Kardacz
In this paper creating optical elements with the use of 3D printing technology was elaborated on. A special focus was put on the properties of nanodiamond and possibilities of applying it in 3D printing process in a mixture with the standard 3D printing resin. Several printouts have been completed, starting from the calibration printouts and ending with optical flats and both cylindrical and spherical lenses. The printouts have been tested for their abilities to transmit and absorb light in a wide spectrum of wavelengths. Full Text: PDF ReferencesL. Ding, R. Wei, and H. Che, Development of a BIM-based automated construction system, Procedia Engineering 85, 123-131 (2014). CrossRef L. Fang, T. Chen, R. Li, S. Liu, Application of embedded fiber Bragg grating (FBG) sensors in monitoring health to 3D printing structures, IEEE Sensors Journal, 16(17), 6604-6610 (2016). CrossRef G. B. Kim, S. Lee, H. Kim, D. H. Yang, Y. H. Kim, Y. S. Kyung, et al., Three-dimensional printing: basic principles and applications in medicine and radiology, Korean Journal of Radiology, 17(2), 182-197 (2016). CrossRef J. W. Stansbury, M. J. Idacavage, 3D printing with polymers: Challenges among expanding options and opportunities, Dental Materials, 32(1), 54-64 (2016). CrossRef G. H. Wu, S. H. Hsu, Polymeric-based 3D printing for tissue engineering, Journal of Medical and Biological Engineering, 35(3), 285-292 (2015). CrossRef https://www.thorlabs.com/newgrouppage9.cfm?objectgroup_id=6973&tabname=N-BK7 DirectLink https://www.thorlabs.com/images/TabImages/UVFS_Transmission_780.gif DirectLink U. Kalsoom, A. Peristyy, P. N. Nesterenko, B. Paull, A 3D printable diamond polymer composite: a novel material for fabrication of low cost thermally conducting devices, RSC Advances, 6(44), 38140-38147 (2016). CrossRef K. M. El-Say, Nanodiamond as a drug delivery system: Applications and prospective, Journal of Applied Pharmaceutical Science, 01(06), 29-39 (2011). DirectLink K. Królewski, MA thesis, 3D printing of optical elements from diamond powders, (2018).

1 October 2018 in Photonics Letters of Poland
Verified
Journal Article
Open access
PDF file
Anna Sękowska-NamiotkoAnna Sękowska-Namiotko
Anna Sękowska-Namiotko
AKAleksandra Kamińska
Aleksandra Kamińska
ASAgnieszka Sabisz
Agnieszka Sabisz
The primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of a magnetic resonance. In this system optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic resonance calibration. Obtained results were compared with magnetic resonance tomography methods used to detect macroscopic spatial differences in composition and heterogeneities in phantoms. Full Text: PDF References Price R. R. et al., Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1., Med Phys. 1990 Mar-Apr;17(2):287-95. CrossRef Tofts P.S., QA: quality assurance, accuracy, precision and phantoms. Chapter 3 in Tofts P.S. (ed.) Quantitative MRI of the brain: measuring changes caused by disease. Chichester: John Wiley, 55-81. ISBN: 0-470-84721-2 CrossRef Wróbel M., Popov A., Bykov A., Tuchin V.V., Jędrzejewska-Szczerska M., Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering, Biomedical Optic Express, vol. 7(6), 2088-2094 (2016). CrossRef Feder I., Wróbel M., Duadi H., Jędrzejewska-Szczerska M., Fixler D., Experimental results of full scattering profile from finger tissue-like phantom, Biomedical Optic Express, vol. 7 (11), 4695-4701 (2016). CrossRef Wróbel M. S. et al., Use of optical skin phantoms for pre-clinical evaluation of laser efficiency for skin lesion therapy, Journal of Biomedical Optics, 20(8), 20(8):085003 (2015). CrossRef Wróbel M .S. et al., Multi-layered tissue head phantoms for noninvasive optical diagnostics, Journal of Innovative Optical Health Sciences, 8(3), 1541005-1÷1541005-10 (2015). CrossRef Hellerbach A, Schuster V, Jansen A, Sommer J., MRI Phantoms - Are There Alternatives to Agar?, Plos One, 2013;8(8), ARTN e70343. CrossRef Almazrouei N. K., Newton M. I., Dye E. R., Morris R. H., Novel food-safe spin-lattice relaxation time calibration samples for use in magnetic resonance sensor development, Proceedings 2018, 2, 122. CrossRef Ohno S. et al., Production of a Human-Tissue-Equivalent MRI Phantom: Optimization of Material Heating, Magn Reson Med Sci. 2008;7(3):131-40. CrossRef Choma M. A., SarunicM. V., Yang C., Izatt J. A., Sensitivity advantage of swept source and Fourier domain optical coherence tomography, Opt. Express 11, 2183-2189 (2003). CrossRef Strąkowski M. R., Głowacki M., Kamińska A., Sawczak M., Gold nanoparticles evaluation using functional optical coherence tomography, Proc. SPIE 10053, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XXI, 1005336 (17 February 2017). CrossRef The primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of a magnetic resonance. In this system optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic resonance calibration. Obtained results were compared with magnetic resonance tomography methods used to detect macroscopic spatial differences in composition and heterogeneities in phantoms. Full Text: PDF References Price R. R. et al., Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1., Med Phys. 1990 Mar-Apr;17(2):287-95. CrossRef Tofts P.S., QA: quality assurance, accuracy, precision and phantoms. Chapter 3 in Tofts P.S. (ed.) Quantitative MRI of the brain: measuring changes caused by disease. Chichester: John Wiley, 55-81. ISBN: 0-470-84721-2 CrossRef Wróbel M., Popov A., Bykov A., Tuchin V.V., Jędrzejewska-Szczerska M., Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering, Biomedical Optic Express, vol. 7(6), 2088-2094 (2016). CrossRef Feder I., Wróbel M., Duadi H., Jędrzejewska-Szczerska M., Fixler D., Experimental results of full scattering profile from finger tissue-like phantom, Biomedical Optic Express, vol. 7 (11), 4695-4701 (2016). CrossRef Wróbel M. S. et al., Use of optical skin phantoms for pre-clinical evaluation of laser efficiency for skin lesion therapy, Journal of Biomedical Optics, 20(8), 20(8):085003 (2015). CrossRef Wróbel M .S. et al., Multi-layered tissue head phantoms for noninvasive optical diagnostics, Journal of Innovative Optical Health Sciences, 8(3), 1541005-1÷1541005-10 (2015). CrossRef Hellerbach A, Schuster V, Jansen A, Sommer J., MRI Phantoms - Are There Alternatives to Agar?, Plos One, 2013;8(8), ARTN e70343. CrossRef Almazrouei N. K., Newton M. I., Dye E. R., Morris R. H., Novel food-safe spin-lattice relaxation time calibration samples for use in magnetic resonance sensor development, Proceedings 2018, 2, 122. CrossRef Ohno S. et al., Production of a Human-Tissue-Equivalent MRI Phantom: Optimization of Material Heating, Magn Reson Med Sci. 2008;7(3):131-40. CrossRef Choma M. A., SarunicM. V., Yang C., Izatt J. A., Sensitivity advantage of swept source and Fourier domain optical coherence tomography, Opt. Express 11, 2183-2189 (2003). CrossRef Strąkowski M. R., Głowacki M., Kamińska A., Sawczak M., Gold nanoparticles evaluation using functional optical coherence tomography, Proc. SPIE 10053, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XXI, 1005336 (17 February 2017). CrossRef

30 June 2018 in Photonics Letters of Poland
Verified
Journal Article
Open access
PDF file
AKAleksandra Kamińska
Aleksandra Kamińska
MSMarcin Strąkowski
Marcin Strąkowski
Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to describe the optical design for one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. Description of the construction and applied hardware solutions have been written. Moreover, a dedicated software tools for signal processing and data acquisition have been developed Full Text: PDF ReferencesStrąkowski, M. R., Pluciński, J., Jędrzejewska-Szczerska, M., Hypszer, R., Maciejewski, M., Kosmowski, B. B., "Polarization sensitive optical coherence tomography for technical materials investigation", Sensors and Actuators A: Physical 142(1), 104-110 (2008). CrossRef J. G. Fujimoto, W. Drexler, Optical Coherence Tomography: Technology and Applications (Biological and Medical Physics, Biomedical Engineering), (New York, Springer 2008). CrossRef Mujat, M., Chan, R. C., Cense, B., Park, B. H., Joo, C., Akkin, T., De Boer, J. F., "Retinal nerve fiber layer thickness map determined from optical coherence tomography images", Opt. Express 13, 9480-9491 (2005). CrossRef Liang, H., Cid, M. G., Cucu, R. G., Dobre, G. M., Podoleanu, A. G., Pedro, J., Saunders, D., "En-face optical coherence tomography-a novel application of non-invasive imaging to art conservation", Opt. Express 13, 6133-6144 (2005). CrossRef Choma, M. A., Sarunic, M. V., Yang, C., Izatt, J. A., "Sensitivity advantage of swept source and Fourier domain optical coherence tomography", Opt. Express 11, 2183-2189 (2003). CrossRef Koyama, T., Marshek, K. M., "Toothed belt drives—past, present and future", Mechanism and machine theory 23(3), 227-241 (1988). CrossRef Ali, M., & Parlapalli, R., "Signal processing overview of optical coherence tomography systems for medical imaging", Texas Instruments, SPRABB9–June (2010). DirectLink B. E. A. Saleh, M. C. Teich, Fundamentals of Photonics, 2nd Edition (New York, Wiley 1991) CrossRef

1 January 2020
Verified
Conference Paper
Closed access
PDF file
AKAleksandra Kamińska
Aleksandra Kamińska
MFMateusz Ficek
Mateusz Ficek
RBRobert Bogdanowicz
Robert Bogdanowicz
JPJerzy Pluciński
Jerzy Pluciński
The main goal of this work was to study properties of free-standing boron-doped diamond sheets using optical coherence tomography (OCT) along with signal processing of the raw data.