Miriam Rodríguez de Rivera Socorro

Mrs. Miriam Rodríguez de Rivera Socorro

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2025 in Modelling
Verified
Journal Article
Open access
PDF file
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
MSMiriam Rodríguez de Rivera Socorro
Miriam Rodríguez de Rivera Socorro
FSFabiola Socorro
Fabiola Socorro
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
This study presents an advanced model of thermal Resistances and heat Capacities model approach (RC model), applied to a custom-built skin calorimeter for the in vivo characterization of localized thermal behavior of the skin. The device integrates a heat flux sensor and a programmable thermostat, and is capable of measuring the heat flux, heat capacity, internal thermal resistance, and subcutaneous temperature of the skin, under both resting and exercising conditions. The model, refined through extensive experimental validation, incorporates the skin as part of the system and is adapted to three modes of operation: calibration base, ambient air, and direct skin contact. Simulations are used to analyze heat flux dynamics, optimize control parameters, and validate analytical expressions. Under resting conditions, the model enables the estimation of the skin’s heat capacity and thermal resistance. During exercise, it allows the determination of heat flux and internal temperature variations using simplified expressions. The system demonstrates high sensitivity (195.5 mV/W) and provides a robust, non-invasive method for extracting medically relevant thermal parameters from a 2 × 2 cm2 skin area.

29 August 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
MSMiriam Rodríguez de Rivera Socorro
Miriam Rodríguez de Rivera Socorro
FSFabiola Socorro
Fabiola Socorro
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
Direct measurement of heat loss in a moving limb requires attached heat-flux sensors, which are strongly affected by convection and radiation. Skin calorimetry minimizes these effects, enabling an accurate measurement. A skin calorimeter was used to measure the heat flux in the rectus femoris (thigh) of a subject exercising for 30 min at a mechanical power of 80 W. In this work, we have developed an analytical model able to describe the thermal evolution of the rectus femoris during exercise and subsequent recovery. This model consists of a sum of two exponentials f(t) = A1(1 − e−t/τ) + A2·t·e−t/τ, with the novelty that the second term is a linear–exponential, which opposes the first term, and that allows the initial thermal transient characterization. The time constants are the most relevant parameters, with mean values of 5 min during exercise and 10 min during recovery (for the 4 cm2 sensing area). The mean exercise amplitude (A1) is 1.1 mW/W, while in post-exercise it is −0.8 mW/W. In addition, the measurement of the thermal resistance of the skin before and after exercise allowed for the estimation and analysis of the evolution of the subcutaneous internal temperature, which follows the same exponential function. The developed mathematical model defines a Transfer Function (TF)—a potential invariant that can predict the thigh’s heat flux response to any exercise protocol (for the subject analyzed). This mathematical approach may be useful for sports and clinical applications.

27 August 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
PRPedro Jesús Rodríguez de Rivera
Pedro Jesús Rodríguez de Rivera
MSMiriam Rodríguez de Rivera Socorro
Miriam Rodríguez de Rivera Socorro
FSFabiola Socorro
Fabiola Socorro
EGEDUARDO GARCÍA GONZÁLEZ
EDUARDO GARCÍA GONZÁLEZ
ENElisabetta De Nigris
Elisabetta De Nigris
MRManuel Rodriguez De Rivera
Manuel Rodriguez De Rivera
In this study, we examined the thermal response of the vastus lateralis muscle using a skin calorimeter designed for localized measurements. Five healthy young male participants (20–23 years old) performed an incremental test on a cycle ergometer at 20 W·min−1 until exhaustion. The calorimeter’s thermostat was maintained at 30 °C. Ambient temperature was 23 ± 1 °C, and relative humidity ranged from 55% to 60%. The measured heat flow was modeled using functions relating mechanical power output to the thermal response. The model included the exercise phase, recovery, and sweat evaporation. The proposed model accurately reproduced the experimental data and supported a physiological interpretation of the main thermal effects. Two major contributions were identified and physiologically interpreted as muscle warming due to increased metabolic activity and a cooling effect likely linked to changes in blood perfusion. For an area of 2 × 2 cm2 and an incremental exercise of 20 W·min−1, the following values were obtained: (1) a resting heat loss of 150 ± 20 mW; (2) an exponential increase due to exercise of 0.4 ± 0.1 mW·W−1, with a time constant of 1.0 ± 0.3 min; and (3) a negative blood-flow contribution described by a function that, in the steady state, has an amplitude of −20 ± 9 mW. Since only five participants were included, correlations with anthropometric variables were treated as exploratory consistency checks. These results demonstrate the usefulness of the calorimeter for decomposing and quantifying muscle thermal dynamics during exercise.

31 December 2025 in Heart
Verified
Journal Article
Closed access
ECElton Carreiro Da Cunha
Elton Carreiro Da Cunha
IOItziar Cucurull Ortega
Itziar Cucurull Ortega
MSMiriam Rodríguez de Rivera Socorro
Miriam Rodríguez de Rivera Socorro
LPLucía Muñoz Prejigueiro
Lucía Muñoz Prejigueiro
LSLucía Abia Sarriá
Lucía Abia Sarriá
CVCristina Ruisanchez Villar
Cristina Ruisanchez Villar
Background: Exercise stress echocardiography (ESE) is widely used to detect inducible myocardial ischaemia. However, a substantial proportion of ESEs remains inconclusive or shows abnormal non-ischaemic findings (fixed regional wall motion abnormalities without new inducible ischaemia), often requiring further testing. Baseline characteristics differ markedly between these groups, highlighting the need for studies that precisely adjust for confounders. This article aims to assess long-term outcomes among patients with negative, non-diagnostic or abnormal non-ischaemic ESE using robust confounder adjusted analyses. Methods: This was a retrospective cohort study conducted between 2017 and 2023 at a tertiary care hospital in Santander, northern Spain. Patients with inducible ischaemia or non-treadmill protocols were excluded. Participants were classified as diagnostic negative (≥85% predicted heart rate), non-diagnostic negative (<85%) or abnormal non-ischaemic (fixed wall motion abnormalities without inducible ischaemia). The primary endpoint was a composite of all-cause mortality, cardiovascular death, ischaemic hospitalisation and coronary angiography. Inverse probability of treatment weighting (IPTW) and generalised pairwise comparisons (GPC) assessed outcomes. Results: During a mean follow-up of 71 months among 788 patients, the overall event rate was 3.2 per 100 patient-years. Adjusted Cox models showed no significant differences between non-diagnostic (HR 0.92; 95% CI 0.49 to 1.72) or abnormal non-ischaemic (HR 0.80; 95% CI 0.24 to 2.61) versus diagnostic negative groups. Independent risk predictors included type 2 diabetes mellitus (HR 2.13; 95% CI 1.13 to 4.03) and lower ejection fraction (HR 0.97 per 1% increase; 95% CI 0.94 to 0.99). GPC identified more angiographies in the negative non-diagnostic group (p=0.04) and greater mortality in the abnormal non-ischaemic group (p=0.02) than in diagnostic negative patients, despite similar composite outcomes. Conclusion: Negative ESE generally predicts low risk; however, non-diagnostic or abnormal non-ischaemic GPC findings show subtle prognostic differences undetected by conventional analysis. These subgroups may warrant closer follow-up or additional imaging.