Jeremy Thomas

Dr. Jeremy Thomas

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2024 in JMIR Cardio
Verified
Journal Article
Open access
MHMartin Huecker
Martin Huecker
CSCraig Schutzman
Craig Schutzman
JFJoshua French
Joshua French
KEKarim El-Kersh
Karim El-Kersh
SGShahab Ghafghazi
Shahab Ghafghazi
JTJeremy Thomas
Jeremy Thomas
Background: Heart failure (HF) contributes greatly to morbidity, mortality, and health care costs worldwide. Hospital readmission rates are tracked closely and determine federal reimbursement dollars. No current modality or technology allows for accurate measurement of relevant HF parameters in ambulatory, rural, or underserved settings. This limits the use of telehealth to diagnose or monitor HF in ambulatory patients. Objective: This study describes a novel HF diagnostic technology using audio recordings from a standard mobile phone. Methods: This prospective study of acoustic microphone recordings enrolled convenience samples of patients from 2 different clinical sites in 2 separate areas of the United States. Recordings were obtained at the aortic (second intercostal) site with the patient sitting upright. The team used recordings to create predictive algorithms using physics-based (not neural networks) models. The analysis matched mobile phone acoustic data to ejection fraction (EF) and stroke volume (SV) as evaluated by echocardiograms. Using the physics-based approach to determine features eliminates the need for neural networks and overfitting strategies entirely, potentially offering advantages in data efficiency, model stability, regulatory visibility, and physical insightfulness. Results: Recordings were obtained from 113 participants. No recordings were excluded due to background noise or for any other reason. Participants had diverse racial backgrounds and body surface areas. Reliable echocardiogram data were available for EF from 113 patients and for SV from 65 patients. The mean age of the EF cohort was 66.3 (SD 13.3) years, with female patients comprising 38.3% (43/113) of the group. Using an EF cutoff of ≤40% versus >40%, the model (using 4 features) had an area under the receiver operating curve (AUROC) of 0.955, sensitivity of 0.952, specificity of 0.958, and accuracy of 0.956. The mean age of the SV cohort was 65.5 (SD 12.7) years, with female patients comprising 34% (38/65) of the group. Using a clinically relevant SV cutoff of 50 mL, the model (using 3 features) had an AUROC of 0.922, sensitivity of 1.000, specificity of 0.844, and accuracy of 0.923. Acoustics frequencies associated with SV were observed to be higher than those associated with EF and, therefore, were less likely to pass through the tissue without distortion. Conclusions: This work describes the use of mobile phone auscultation recordings obtained with unaltered cellular microphones. The analysis reproduced the estimates of EF and SV with impressive accuracy. This technology will be further developed into a mobile app that could bring screening and monitoring of HF to several clinical settings, such as home or telehealth, rural, remote, and underserved areas across the globe. This would bring high-quality diagnostic methods to patients with HF using equipment they already own and in situations where no other diagnostic and monitoring options exist.

18 June 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
CGCaroline Gosser
Caroline Gosser
LDLuther Daniel
Luther Daniel
MHMartin Huecker
Martin Huecker
RCRodrigo Cavallazzi
Rodrigo Cavallazzi
HRHiram Rivas
Hiram Rivas
RCRyan Close
Ryan Close
Background/Objectives: Chronic obstructive pulmonary disease (COPD) remains a condition with high morbidity, mortality, and misdiagnosis. The gold standard pulmonary function testing with spirometry has limited availability. This study seeks to test a novel diagnostic test based on auscultatory mapping of pulmonary dynamics. This NIH-funded study aimed to develop a COPD detection technology, using mobile phone auscultation, for situations in which spirometry is not available. Methods: This prospective study collected mobile phone auscultation data on patients presenting for spirometry and evaluation by a pulmonologist. All subjects had same-day or recent (less than 6 months) spirometry in one PFT laboratory. After informed consent, the subjects underwent respiratory auscultation using a selection of mobile phone brands. The auscultation methods included normal breathing observed at the left axillary site and egophony observed at the right supra clavicular fossa. The team created models from the recordings using Time Series Dynamics (TSD), proprietary software that uses computational nonlinear dynamics to characterize the respiratory biofluid dynamics implied by the acoustic data. Results: We enrolled a total of 108 patients (34.3% male), from 19 to 85 years of age (median 61 years). Among the patients, 64 (59.3%) subjects identified as White, 43 (39.8%) as Black, and 1 as Asian. Among the two cohorts with diverse comorbidities, 52 subjects had confirmed COPD and 56 did not. The cohorts differed significantly in age and body mass index, but not in race, number of comorbidities, or COPD assessment test scores. They had significant differences in forced expiratory volume in 1 s (FEV1), the FEV1/FVC (forced vital capacity) ratio, but not FVC. The recordings from the egophonic and axillary sites were initially modeled separately and then combined in a single composite model. The modeling produced excellent results with 90%+ AUC and sensitivity in both the test and train sets relative to the gold standard. Conclusions: Evidence suggests that a mobile phone auscultation device can accurately determine COPD diagnosis. In frontline applications where the availability of gold standard pulmonary function testing is limited, the device could improve the detection of COPD, a condition with significant over- and under-diagnosis. Future trials will investigate the ability of patients to self-record. Success would support remote COPD testing using transmitted telehealth recording data, bringing diagnosis to patients in underserved populations.

5 February 2024 in JMIR Preprints
Verified
Preprint
Open access
MHMartin Huecker
Martin Huecker
CSCraig Schutzman
Craig Schutzman
JFJoshua French
Joshua French
KEKarim El-Kersh
Karim El-Kersh
SGShahab Ghafghazi
Shahab Ghafghazi
JTJeremy Thomas
Jeremy Thomas
BACKGROUND Heart failure (HF) contributes greatly to morbidity, mortality, and health care costs worldwide. Hospital readmission rates are tracked closely and determine federal reimbursement dollars. No current modality or technology allows for accurate measurement of relevant HF parameters in ambulatory, rural, or underserved settings. This limits the use of telehealth to diagnose or monitor HF in ambulatory patients. OBJECTIVE This study describes a novel HF diagnostic technology using audio recordings from a standard mobile phone. METHODS This prospective study of acoustic microphone recordings enrolled convenience samples of patients from 2 different clinical sites in 2 separate areas of the United States. Recordings were obtained at the aortic (second intercostal) site with the patient sitting upright. The team used recordings to create predictive algorithms using physics-based (not neural networks) models. The analysis matched mobile phone acoustic data to ejection fraction (EF) and stroke volume (SV) as evaluated by echocardiograms. Using the physics-based approach to determine features eliminates the need for neural networks and overfitting strategies entirely, potentially offering advantages in data efficiency, model stability, regulatory visibility, and physical insightfulness. RESULTS Recordings were obtained from 113 participants. No recordings were excluded due to background noise or for any other reason. Participants had diverse racial backgrounds and body surface areas. Reliable echocardiogram data were available for EF from 113 patients and for SV from 65 patients. The mean age of the EF cohort was 66.3 (SD 13.3) years, with female patients comprising 38.3% (43/113) of the group. Using an EF cutoff of ≤40% versus >40%, the model (using 4 features) had an area under the receiver operating curve (AUROC) of 0.955, sensitivity of 0.952, specificity of 0.958, and accuracy of 0.956. The mean age of the SV cohort was 65.5 (SD 12.7) years, with female patients comprising 34% (38/65) of the group. Using a clinically relevant SV cutoff of 50 mL, the model (using 3 features) had an AUROC of 0.922, sensitivity of 1.000, specificity of 0.844, and accuracy of 0.923. Acoustics frequencies associated with SV were observed to be higher than those associated with EF and, therefore, were less likely to pass through the tissue without distortion. CONCLUSIONS This work describes the use of mobile phone auscultation recordings obtained with unaltered cellular microphones. The analysis reproduced the estimates of EF and SV with impressive accuracy. This technology will be further developed into a mobile app that could bring screening and monitoring of HF to several clinical settings, such as home or telehealth, rural, remote, and underserved areas across the globe. This would bring high-quality diagnostic methods to patients with HF using equipment they already own and in situations where no other diagnostic and monitoring options exist.