Chongbin Liu

Mr. Chongbin Liu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LSLei Shi
Lei Shi
LJLicheng Jia
Licheng Jia
CLChongbin Liu
Chongbin Liu
CSChengliang Sun
Chengliang Sun
SLsheng liu
sheng liu
GWGuoqiang Wu
Guoqiang Wu
A miniaturized ultrasonic sugar concentration detection system based on piezoelectric micromachined ultrasonic transducers (PMUTs) is presented in this work. An $8\times 9$ PMUT array together with a TDC1000 ultrasonic sensing analog front end is used to alternately transmit and receive ultrasonic signals. A PT1000 temperature sensor is employed for real-time monitoring the solution temperatures. The acquired and processed signals are sequentially subjected to ultrasonic time-of-flight (TOF), ultrasonic velocity, and sugar concentration calculations, followed by a temperature compensation by a microcontroller unit (MCU). A feasibility evaluation of the designed ultrasonic sugar concentration detection system is conducted. A sucrose solution is selected as the measurement sample. Measurement results show that the reported system can be used to determine sugar concentration in solutions well and can perform automatic temperature compensation. The reported ultrasonic sugar concentration system has a fast response of less than 1 s, an accuracy of 1.4%, and a high resolution of 0.6%, which is comparable to the classical optical saccharimeter. Furthermore, the reported system can be designed as a small catheter-based test probe with high portability for portable sugar concentration detections in food industry because of the compact size of the PMUT sensor.

28 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HLHanzhe Liu
Hanzhe Liu
XWXiangyang Wang
Xiangyang Wang
CLChongbin Liu
Chongbin Liu
YLYuzhe Lin
Yuzhe Lin
LZLujiang Zhang
Lujiang Zhang
JTJifang Tao
Jifang Tao
This paper presents an ultrasonic gas meter based on a scandium-doped aluminum nitride (Sc 0.2 Al 0.8 N) piezoelectric micromachined ultrasonic transducer (PMUT) array, where the characteristic dimension of each PMUT cell is only 600 μ m . The ultrasonic time of flight (TOF) difference method is employed to measure the gas flow rate, followed by ultrasonic signal processing and subsequent velocity profile and temperature compensation performed by the microcontroller. The cross correlation method is employed to detect the ultrasonic TOF difference and further suppress noise. In order to conduct a feasibility evaluation of the designed ultrasonic gas meter, the PMUT array, system control circuit and ultrasonic flow channel are combined and encapsulated in a meter case. Results indicate that the ultrasonic gas meter exhibits outstanding accuracy, repeatability and temperature adaptability. In the flow range of 0.025 m 3 /h to 2.8 m 3 /h, the minimum mean error and minimum repeatability error are 0.11% and 0.13%, respectively. Even when the temperature reaches 323.15 K, the designed device can achieve a mean error of no more than 0.41% with temperature compensation, which is comparable to commercialized ultrasonic gas meters. The highly reliable ultrasonic gas meter presented in this paper will provide a feasible solution for advancing portable devices.

29 August 2022 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
CLChongbin Liu
Chongbin Liu
LJLicheng Jia
Licheng Jia
LSLei Shi
Lei Shi
CSChengliang Sun
Chengliang Sun
DCDaw Don Cheam
Daw Don Cheam
GWGuoqiang Wu
Guoqiang Wu
In this work, we reported a theoretical model for a novel piezoelectric micromachined ultrasonic transducer (PMUT). The sensing cells with hexagonal transduction diaphragms in the PMUT array are designed and arranged in a bioinspired honeycomb structure. Based on the classical piece-wise approach commonly used for PMUT with circular diaphragm, an enhanced theoretical model is developed. In this model, the deflection of the honeycomb diaphragm is analytically determined by the volume deflection, rather than the path deflection commonly used in the previous models. The hexagonal diaphragm is converted as a circular one, whose radius is derived by correcting the characteristic size of the hexagonal diaphragm multiplied by a correction factor. The calculated parameters by the reported theoretical model of a transduction cell in the PMUT array, such as resonant frequency and static deflection, matched well with the data obtained by finite element analysis and experiment. Special investigations are made on the effects of top electrode coverage and transduction layer thickness towards PMUT’s performance. The reported theoretical model in this work is suitable not only for PMUTs with circular and hexagonal transduction cells, but also for square and other arbitrary shape diaphragms. This enhanced theoretical model provides an interesting insight on design optimizations of PMUT with various transduction cell geometries.2022-0093

19 November 2021 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
LSLei Shi
Lei Shi
LJLicheng Jia
Licheng Jia
CLChongbin Liu
Chongbin Liu
Hongbin YuHongbin Yu
Hongbin Yu
CSChengliang Sun
Chengliang Sun
GWGuoqiang Wu
Guoqiang Wu
In this paper, a low noise amplification circuit is designed for aluminum nitride-based piezoelectric micromachined ultrasonic transducers (PMUTs) with three different sensing configurations. The acoustic pressure sensitivity and noise resolution of PMUTs corresponding to different readout configurations are analyzed and characterized. With the differential readout configuration, the acoustic pressure sensitivity of the PMUTs is improved by 5.76 dB (re: 1 V µ Pa −1 ) on average, and the noise resolution is reduced by about 8 dB at 500 Hz (re: 1 µ Pa (Hz 1 / 2 ) −1 ). Compared to the conventional readout configuration, both theoretical analysis and measurement results show that the output voltage of PMUTs is doubled with the differential readout configuration and thus the acoustic pressure sensitivity is improved. Moreover, the noise resolution of PMUTs is reduced and thus the signal-to-noise is improved. This work offers new insight on improving the receiving performance of PMUTs.

23 May 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
CLChongbin Liu
Chongbin Liu
XWXiangyang Wang
Xiangyang Wang
JXJianbiao Xiao
Jianbiao Xiao
Jun ZhouJun Zhou
Jun Zhou
GWGuoqiang Wu
Guoqiang Wu
Speech recognition in noisy environments has long posed a challenge. Air conduction microphone (ACM), the devices typically used, are susceptible to environmental noise. In this work, a customized bone conduction microphone (BCM) system based on a piezoelectric micromachined ultrasonic transducer is developed to capture speech through real-time bone conduction (BC), while a commercial ACM is integrated for simultaneous capture of speech through air conduction (AC). The system enables simpler and more robust BC speech capture. The BC speech capture achieves a signal-to-noise amplitude ratio over five times greater than that of AC speech capture in an environment with a noise level of 68 dB. Instead of using only AC-captured speech, both BC- and AC-captured speech are input into a speech enhancement module. The noise-insensitive BC-captured speech serves as a speech reference to adapt the SE backbone of AC-captured speech. The two types of speech are fused, and noise suppression is applied to generate enhanced speech. Compared with the original noisy speech, the enhanced speech achieves a character error rate reduction of over 20%, approaching the speech recognition accuracy of clean speech. The results indicate that this speech enhancement method based on the fusion of BC- and AC-captured speech efficiently integrates the features of both types of speech, thereby improving speech recognition accuracy in noisy environments. This work presents an innovative system designed to efficiently capture BC speech and enhance speech recognition in noisy environments.

29 August 2025 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
XWXiangyang Wang
Xiangyang Wang
CLChongbin Liu
Chongbin Liu
JZJian Zhang
Jian Zhang
SLsheng liu
sheng liu
GWGuoqiang Wu
Guoqiang Wu
In this letter, the influence of back-cavity package design on the transmitting sensitivity of piezoelectric micromachined ultrasonic transducers (PMUTs) with open back cavities is investigated. The reported PMUTs are fabricated based on a thin-film piezoelectric on silicon-on-insulator (SOI) platform with backside cavities in substrate to define the vibration diaphragms. An adjustable package with back-cavity depth control and reflective interface selection is proposed. The transmitting sensitivity of the PMUTs is largely influenced by the package design, due to the constructive or destructive interferences between the reflective acoustic waves in the back cavity and the originally transmitted forward acoustic waves. Experimental results illustrate that the measured vibration amplitude of the diaphragm in the PMUTs demonstrates sinusoidal-shaped variations as the back-cavity depth continuously increases under a reflective interface, such as aluminum alloy and cardboard. With a proper back-cavity package design, the reported PMUTs demonstrate a 1.3-fold enhancement of vibration amplitude compared with those without the interferences of reflective waves. This work highlights an effective approach for enhancing the transmitting sensitivity of PMUTs.