Fernando Crivellaro

Mr. Fernando Crivellaro

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DSDavid Santos
David Santos
Miguel A. MachadoMiguel A. Machado
Miguel A. Machado
JMJoão Monteiro
João Monteiro
JSJosé P. Sousa
José P. Sousa
Carla Sofia ProençaCarla Sofia Proença
Carla Sofia Proença
Telmo SantosTelmo Santos
Telmo Santos
This paper presents an automated Non-Destructive Testing (NDT) system for the in-service inspection of orbital welds on tubular components operating at temperatures as high as 200 °C. The combination of two different NDT methods and respective inspection systems is here proposed to cover the detection of all potential defective weld conditions. The proposed NDT system combines ultrasounds and Eddy current techniques with dedicated approaches for dealing with high temperature conditions. Phased array ultrasound was employed, searching for volumetric defects within the weld bead volume while Eddy currents were used to look for surface and sub-surface cracks. The results from the phased array ultrasound results showed the effectiveness of the cooling mechanisms and that temperature effects on sound attenuation can be easily compensated for up to 200 °C. The Eddy current results showed almost no influence when temperatures were raised up to 300 °C.

23 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
FCFernando Crivellaro
Fernando Crivellaro
ACAnselmo Costa
Anselmo Costa
PVPedro M. Vieira
Pedro M. Vieira
Bilirubin is a product of the metabolism of hemoglobin from red blood cells. Higher levels of bilirubin are a sign that either there is an unusual breaking down rate of red blood cells or the liver is not able to eliminate bilirubin, through bile, into the gastrointestinal tract. For adults, bilirubin is occasionally monitored through urine or invasive blood sampling, whilst all newborns are routinely monitored visually, or non-invasively with transcutaneous measurements (TcBs), due to their biological immaturity to conjugate bilirubin. Neonatal jaundice is a common condition, with higher levels of unconjugated bilirubin concentration having neurotoxic effects. Actual devices used in TcBs are focused on newborn populations, are hand-held, and, in some cases, operate in only two wavelengths, which does not necessarily guarantee reliable results over all skin tones. The same occurs with visual inspections. Based on that, a continuous bilirubin monitoring device for newborns is being developed to overcome visual inspection errors and to reduce invasive procedures. This device, operating optically with a mini-spectrometer in the visible range, is susceptible to patient movements and, consequently, to situations with a lower signal quality for reliable bilirubin concentration estimates on different types of skin. Therefore, as an intermediate development step and, based on skin spectra measurements from adults, this work addresses the device’s placement status prediction as a signal quality indication index. This was implemented by using machine learning (ML), with the best performances being achieved by support vector machine (SVM) models, based on the spectra acquired on the arm and forehead areas.

30 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
FCFernando Crivellaro
Fernando Crivellaro
ASAna Isabel Sousa
Ana Isabel Sousa
ACAnselmo Costa
Anselmo Costa
PVPedro M. Vieira
Pedro M. Vieira
Newborn immaturity transcends their bodies, immune systems, and communication and perception capabilities, making them vulnerable to the environment. Neonatal jaundice is a common condition, with higher levels of unconjugated bilirubin concentration having neurotoxic effects. Newborns are routinely monitored visually or non-invasively with transcutaneous bilirubinometry (TcB) due to their biological immaturity to conjugate bilirubin. Higher levels of bilirubin are a sign that there is either an unusual rate of red blood cells breaking down or that the liver is not able to eliminate bilirubin through bile into the gastrointestinal tract. Actual devices used in bilirubin screening are hand-held and do not allow operation outside the hospital. Based on these factors, a continuous bilirubin monitoring device for newborns was developed, which enables the evaluation of neonatal jaundice inside or outside the hospital. This non-invasive device operates through a mini-spectrometer in the visible range. It was calibrated with phantoms, and its operation was compared with a gold-standard bilirubinometer through in vitro experiments, exploring the practical range of bilirubin variation in newborns and presenting a clinically acceptable deviation of 1 mg/dL. These experiments showed that the continuous bilirubin monitoring device developed has the potential to be used for remote monitoring of jaundice in newborns.