Ana Isabel Sousa

Ms. Ana Isabel Sousa

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2016 in Carbohydrate Polymers
Verified
Journal Article
Closed access
Paula SoaresPaula Soares
Paula Soares
ASAna Isabel Sousa
Ana Isabel Sousa
Jorge Carvalho SilvaJorge Carvalho Silva
Jorge Carvalho Silva
IFIsabel Ferreira
Isabel Ferreira
CNCarlos M.M. Novo
Carlos M.M. Novo
João BorgesJoão Borges
João Borges



1 January 2022
Verified
Book Chapter
Closed access
PDF file
ASAna Isabel Sousa
Ana Isabel Sousa
CNCarlos Marques Neves
Carlos Marques Neves
PVPedro Vieira
Pedro Vieira

9 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
ASAna Isabel Sousa
Ana Isabel Sousa
CMCarlos Marques-Neves
Carlos Marques-Neves
PVPedro M. Vieira
Pedro M. Vieira
Chromatic Pupillometry, used to assess Pupil Light Reflex (PLR) to a coloured light stimulus, has regained interest since the discovery of melanopsin in the intrinsically photosensitive Retinal Ganglion Cells (ipRGCs). This technique has shown the potential to be used as a screening tool for neuro-ophthalmological diseases; however, most of the pupillometers available are expensive and not portable, making it harder for them to be used as a widespread screening tool. In this study, we developed a smartphone-based system for chromatic pupillometry that allows targeted stimulation of the ipRGCs. Using a smartphone, this system is portable and accessible and takes advantage of the location of the ipRGCs in the perifovea. The system incorporates a 3D-printed support for the smartphone and an illumination system. Preliminary tests were carried out on a single individual and then validated on eleven healthy individuals with two different LED intensities. The average Post-Illumination Pupil Light Response 6 s after the stimuli offsets (PIPR-6s) showed a difference between the blue and the red stimuli of 9.5% for both intensities, which aligns with the studies using full-field stimulators. The results validated this system for a targeted stimulation of the ipRGCs for chromatic pupillometry, with the potential to be a portable and accessible screening tool for neuro-ophthalmological diseases.

30 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
FCFernando Crivellaro
Fernando Crivellaro
ASAna Isabel Sousa
Ana Isabel Sousa
ACAnselmo Costa
Anselmo Costa
PVPedro M. Vieira
Pedro M. Vieira
Newborn immaturity transcends their bodies, immune systems, and communication and perception capabilities, making them vulnerable to the environment. Neonatal jaundice is a common condition, with higher levels of unconjugated bilirubin concentration having neurotoxic effects. Newborns are routinely monitored visually or non-invasively with transcutaneous bilirubinometry (TcB) due to their biological immaturity to conjugate bilirubin. Higher levels of bilirubin are a sign that there is either an unusual rate of red blood cells breaking down or that the liver is not able to eliminate bilirubin through bile into the gastrointestinal tract. Actual devices used in bilirubin screening are hand-held and do not allow operation outside the hospital. Based on these factors, a continuous bilirubin monitoring device for newborns was developed, which enables the evaluation of neonatal jaundice inside or outside the hospital. This non-invasive device operates through a mini-spectrometer in the visible range. It was calibrated with phantoms, and its operation was compared with a gold-standard bilirubinometer through in vitro experiments, exploring the practical range of bilirubin variation in newborns and presenting a clinically acceptable deviation of 1 mg/dL. These experiments showed that the continuous bilirubin monitoring device developed has the potential to be used for remote monitoring of jaundice in newborns.