Objective: To evaluate the cytotoxic and genotoxic effects of a phytotherapeutic ointment containing 2% L. ferrea L extract. Material and Methods: Libidibia ferrea L. barks were used as raw material. The extract was prepared by decoction under reflux in a hydroalcoholic solution. The extract concentration in the orabase formulation was determined based on the minimum inhibitory concentration. Biocompatibility was assessed by cell culture tests from MRC5 human fibroblasts. The Alamar Blue test evaluated cytotoxicity; the Trypan Blue Solution trial evaluated cell viability. The comet assay on alkaline and neutral pH assessed genotoxicity. Test results were tabulated and analyzed through descriptive and inferential statistics, with ANOVA Test (p≤ 0.05). Results: No cytotoxic activity or morphological induction of cell death for the test formulation. Regarding genotoxicity, the Juca formulation could not induce DNA damage in MRC-5 at 25 and 50 μg/mL concentrations through the comet assay at neutral or alkaline pH. Conclusion: The tested formulation is biocompatible, and no cytotoxic or genotoxic effects were observed under test conditions, demonstrating viability for future in vivo tests.
Purpose: To analyze the influence of the type of cement, aging, and implant connection regarding the Institute of Excellence in Teaching and Research-IETR Institute of Excellence in Teaching and Research-IETR retention capacity of zirconia crowns cemented onto the Titanium base abutment Material and methods: The specimens was divided into four groups: Ti-Base External Hexagon 5,0x4,7x1,0 mm (n=20) or Ti-Base Morse Taper 5,0x4,7x1,5 mm (n=20), temporary or definitive cement, and mechanical aging (with or without). All the samples underwent a tensile test. Results: Data analysis was assessed using the Shapiro-Wilk, three-way ANOVA with repeated measures, and Tukey's test (P < 0.05). The failure mode was also recorded. The Morse taper implants presented a statisti-cally significantly higher average retention strength than the external hexagon implants. Groups III and IV presented the highest value compared to the other groups (565 and 491 N). Most mixed failures were found for all groups. Conclusion: Mechanical aging imped-ed the retention force of milled zirconia crowns cemented on titanium base abutments with resin cement on Morse taper implants had greater retention force compared to exter-nal hexagon implants.
This study aimed was to compare the tensile strength of a dental cement based on copaiba resin-oil with the temporary cement RelyX Temp NE (3M, Sumaré-SP, Brazil) in bisacrylic resin crowns. Ten human third molars ,standardized prepared to total crowns, recived temporary crowns cemented with the copaiba cement and the others ten with RelyX Temp NE (3M, Sumaré-SP,Brazil). The twenty samples passed by twenty-four hours immersed in artificial saliva, and then the crowns were tractioned in a universal testing machine at 1.0 mm/min. The crowns cemented with copaiba resin-oil showed tensile strength statistically higher when compared to those cemented with RelyX Temp NE (3M, Sumaré-SP,Brazil).