André Luiz Moreno

Dr. André Luiz Moreno

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AMAmália Moreno
Amália Moreno
DSDaniela Micheline Dos Santos
Daniela Micheline Dos Santos
CNClóvis Lamartine de Moraes Melo Neto
Clóvis Lamartine de Moraes Melo Neto
AMAndré Luiz Moreno
André Luiz Moreno
ABAndré De Magalhães Bertoz
André De Magalhães Bertoz
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
The aim of this study was to evaluate the effect of disinfectants on the biofilm of Staphylococcus aureus and Staphylococcus epidermidis formed on the acrylic surface of ocular prostheses. In this study, 396 acrylic specimens were manufactured (50% for Staphylococcus epidermidis, and 50% for Staphylococcus aureus). For each bacterium, 66 specimens were subjected to biofilm formation on their surfaces for 24 hours, 66 specimens were subjected to biofilm formation on their surfaces for 48 hours, and 66 specimens were subjected to biofilm formation on their surfaces for 72 hours. Then, they were divided into groups according to disinfection method (n = 6): sterile distilled water for 10, 15, 30 min, and 6 hours (control); soap for 30 min (NES30); Opti-Free for 30 min (OPF30) and 6 h (OPF6); Efferdent for 15 min (EFF15); and 0.5%, 2%, and 4% chlorhexidine for 10 min (0.5% CHX10, 2% CHX10, and 4% CHX10). After the treatments, the specimens were vortexed to release the biofilm and the counting of bacterial colonies was performed (CFU/mL). Three-way ANOVA and the Tukey-Kramer HSD test were used (α = 0.05). For Staphylococcus epidermidis, there was no significant difference between NES30, OPF30, and OPF6 with their respective control groups; nor between NES30, OPF30, and OPF6 themselves, regardless of the biofilm development period (P >0.05). For Staphylococcus aureus, there was no significant difference between NES30 and OPF30 with their control group; nor between NES30 and OPF30 themselves, regardless of the biofilm development period (P >0.05). For Staphylococcus aureus, OPF6 showed a significant reduction in the number of CFU/mL when compared with its control group, NES30, and OPF30, regardless of the biofilm development period (P <0.05). For both bacteria, 0.5% CHX10, 2% CHX10,4% CHX10, and EFF15 showed a significant reduction in the number of CFU/mL when compared with their control groups, NES30, OPF30, and OPF6, regardless of the biofilm development period (P <0.05). Therefore, EFF15 and CHX (0.5%, 2% and 4%) were effective in reducing Staphylococcus epidermidis and Staphylococcus aureus on acrylic surfaces. NES30 and OPF (30 and 6) are not recommended.

1 October 2020 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
ANAdhara Smith Nobrega
Adhara Smith Nobrega
CNClóvis Lamartine de Moraes Melo Neto
Clóvis Lamartine de Moraes Melo Neto
ABAndré Pinheiro de Magalhães Bertoz
André Pinheiro de Magalhães Bertoz
AMAndré Luiz Moreno
André Luiz Moreno
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
Objective The aim of this study is to verify the influence of three pigment incorporation methods (conventional, mechanical, and industrial) on the sorption and solubility of the MDX4-4210 and A-2186 silicones. Materials and Methods The groups formed were based on the silicones used (A-2186 and MDX4-4210), intrinsic pigments (pink, bronze, and black), and pigment incorporation methods (conventional, mechanical, and industrial). The dimensions of all samples were 45-mm diameter (ø) × 1-mm thickness. Readings were taken initially and after 1,008 hours of aging. Statistical Analysis Three-way analysis of variance and the Tukey's test were performed (α = 0.05). Results For sorption and solubility, there was no difference between the incorporation methods for the A-2186 silicone, regardless of the pigment used (p > 0.05). For pink MDX4-4210, the industrial and mechanical methods showed higher values of sorption compared with the conventional method (p < 0.05). For bronze MDX4-4210, the industrial method showed a higher sorption value compared with the conventional and mechanical methods (p < 0.05). For black MDX4-4210, there was no difference between incorporation methods based on sorption (p > 0.05). For pink MDX4-4210, the mechanical method showed a higher solubility value compared with the industrial and conventional methods (p < 0.05). For black MDX4-4210 and bronze MDX4-4210, there was no statistically significant difference between incorporation methods based on solubility (p > 0.05). Conclusion Based on sorption and solubility, for the A-2186 silicone, the conventional, mechanical, and industrial methods of pigment incorporation were equivalent. For the MDX4-4210 silicone, its results of sorption and solubility were varied, and further studies are recommended.

16 July 2024 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
AMAndré Luiz Moreno
André Luiz Moreno
MCMarcio Campaner
Marcio Campaner
CNClóvis Lamartine de Moraes Melo Neto
Clóvis Lamartine de Moraes Melo Neto
NMNathaly Vilene de Araújo Moreno
Nathaly Vilene de Araújo Moreno
DSDaniela Micheline dos Santos
Daniela Micheline dos Santos
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
Objective The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical–buccal areas around these types of implants. Materials and Methods This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant (3.75 × 11.5 mm) in the area of artificial tooth 15. The strain gauges were glued to the mesial, distal, and apical–buccal polyurethane areas of all samples in relation to the implant. Ti-Base nonangled abutments were installed on the implants in each group. Ten identical zirconia crowns were constructed by scanning and milling and were subsequently cemented onto the Ti-base abutments with calcium hydroxide cement. Then, an axial load of 100 N was applied to the occlusal region of the zirconia crowns, and strain gauge measurements were taken. Statistical Analysis Strain gauge data were assessed by a two-way analysis of variance (ANOVA) with “implant connection” and “strain gauge position” factors, followed by the Bonferroni test (p < 0.05). Results The MT group showed significantly lower microstrain values in the mesial and apical strain gauges compared to the EH group. Conclusion The MT group exhibited less microstrain in the mesial and apical areas of the polyurethane samples near the implant. Consequently, the MT connection was considered more biomechanically advantageous.

25 April 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AMAndré Luiz Moreno
André Luiz Moreno
DSDaniela Micheline Dos Santos
Daniela Micheline Dos Santos
CNClóvis Lamartine de Moraes Melo Neto
Clóvis Lamartine de Moraes Melo Neto
RMRenata Vasconcelos Monteiro
Renata Vasconcelos Monteiro
CLCássia Cunha De Lima
Cássia Cunha De Lima
MGMarcelo Coelho Coelho Goiato
Marcelo Coelho Coelho Goiato
Purpose: To analyze the influence of the type of cement, aging, and implant connection regarding the Institute of Excellence in Teaching and Research-IETR Institute of Excellence in Teaching and Research-IETR retention capacity of zirconia crowns cemented onto the Titanium base abutment Material and methods: The specimens was divided into four groups: Ti-Base External Hexagon 5,0x4,7x1,0 mm (n=20) or Ti-Base Morse Taper 5,0x4,7x1,5 mm (n=20), temporary or definitive cement, and mechanical aging (with or without). All the samples underwent a tensile test. Results: Data analysis was assessed using the Shapiro-Wilk, three-way ANOVA with repeated measures, and Tukey's test (P < 0.05). The failure mode was also recorded. The Morse taper implants presented a statisti-cally significantly higher average retention strength than the external hexagon implants. Groups III and IV presented the highest value compared to the other groups (565 and 491 N). Most mixed failures were found for all groups. Conclusion: Mechanical aging imped-ed the retention force of milled zirconia crowns cemented on titanium base abutments with resin cement on Morse taper implants had greater retention force compared to exter-nal hexagon implants.