Alan Kardek Rêgo Segundo

Dr. Alan Kardek Rêgo Segundo

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2015 in Sensors
Verified
Journal Article
Open access
PDF file
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
JMJosé Martins
José Martins
PMPaulo Monteiro
Paulo Monteiro
RORubens Alves De Oliveira
Rubens Alves De Oliveira
GFGustavo Medeiros Freitas
Gustavo Medeiros Freitas
The scarcity of drinking water affects various regions of the planet. Although climate change is responsible for the water availability, humanity plays an important role in preserving this precious natural resource. In case of negligence, the likely trend is to increase the demand and the depletion of water resources due to the increasing world population. This paper addresses the development, design and construction of a low cost system for measuring soil volumetric water content (θ), electrical conductivity (σ) and temperature (T), in order to optimize the use of water, energy and fertilizer in food production. Different from the existing measurement instruments commonly deployed in these applications, the proposed system uses an auto-balancing bridge circuit as measurement method. The proposed models to estimate θ and σ and correct them in function of T are compared to the ones reported in literature. The final prototype corresponds to a simple circuit connected to a pair of electrode probes, and presents high accuracy, high signal to noise ratio, fast response, and immunity to stray capacitance. The instrument calibration is based on salt solutions with known dielectric constant and electrical conductivity as reference. Experiments measuring clay and sandy soils demonstrate the satisfactory performance of the instrument.

14 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
AFAntonio Evangelista de Freitas
Antonio Evangelista de Freitas
TMTaíse Matte MATTE Manhabosco
Taíse Matte MATTE Manhabosco
RBRonaldo Junio Campos Batista
Ronaldo Junio Campos Batista
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
HAHumberto X. Araújo
Humberto X. Araújo
ACAdilson Rodrigues da Costa
Adilson Rodrigues da Costa
Titanium dioxide substrates have been synthesized by means of solid-state reactions with sintering temperatures varying from 1150 °C up to 1350 °C. X-ray diffraction and scanning electron microscopy (SEM) where employed to investigate the crystal structure, grain size and porosity of the resulting samples. The obtained ceramics are tetragonal (rutile phase) with average grain sizes varying from 2.94 µm up to 5.81 µm. The average grain size of samples increases with increasing temperature, while the porosity decreases. The effect of microstructure on the dielectric properties has been also studied. The reduction of porosity of samples significantly improves the dielectric parameters (relative dielectric permittivity and loss tangent) in comparison to those of commercial substrates, indicating that the obtained ceramic substrates could be useful in the miniaturization of telecommunication devices.

4 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
ÉPÉrica Silva Pinto
Érica Silva Pinto
GSGabriel Santos
Gabriel Santos
PMPaulo Monteiro
Paulo Monteiro
The most widely used technique for measuring capacitive impedances (or complex electrical permittivity) is to apply a frequency signal to the sensor and measure the amplitude and phase of the output signal. The technique, although efficient, involves high-speed circuits for phase measurement, especially when the medium under test has high conductivity. This paper presents a sensor to measure complex electrical permittivity based on an alternative approach to amplitude and phase measurement: The application of two distinct frequencies using a current-to-voltage converter circuit based in a transimpedance amplifier, and an 8-bit microcontroller. Since there is no need for phase measurement and the applied frequency is lower compared to the standard method, the circuit presents less complexity and cost than the traditional technique. The main advance presented in this work is the use of mathematical modeling of the frequency response of the circuit to make it possible for measuring the dielectric constant using a lower frequency than the higher cut-off frequency of the system, even when the medium under test has high conductivity (tested up to 1220 μS/cm). The proposed system caused a maximum error of 0.6% for the measurement of electrical conductivity and 2% for the relative dielectric constant, considering measurement ranges from 0 to 1220 μS/cm and from 1 to 80, respectively.

1 April 2011 in Engenharia Agrícola
Verified
Journal Article
Open access
PDF file
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
JMJosé H. Martins
José H. Martins
PMPaulo M. de B. Monteiro
Paulo M. de B. Monteiro
RORrubens A. de Oliveira
Rrubens A. de Oliveira
DFDelly Oliveira Filho
Delly Oliveira Filho
The irrigation management based on the monitoring of the soil water content allows for the minimization of the amount of water applied, making its use more efficient. Taking into account these aspects, in this work, a sensor for measuring the soil water content was developed to allow real time automation of irrigation systems. This way, problems affecting crop yielding such as irregularities in the time to turn on or turn off the pump, and excess or deficit of water can be solved. To develop the sensors were used stainless steel rods, resin, and insulating varnish. The sensors measuring circuit was based on a microcontroller, which gives its output signal in the digital format. The sensors were calibrated using soil of the type “Quartzarenic Neosoil”. A third order polynomial model was fitted to the experimental data between the values of water content corresponding to the field capacity and the wilting point to correlate the soil water content obtained by the oven standard method with those measured by the electronic circuit, with a coefficient of determination of 93.17%, and an accuracy in the measures of ±0.010 kg kg-1. Based on the results, it was concluded that the sensor and its implemented measuring circuit can be used in the automation process of irrigation systems.

21 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Rodolfo LeocádioRodolfo Leocádio
Rodolfo Leocádio
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
CLCibelle Ferreira Louzada
Cibelle Ferreira Louzada
This work proposes adapting an existing sensor and embedding it on mannequins used in cardiopulmonary resuscitation (CPR) training to accurately measure the amount of air supplied to the lungs during ventilation. Mathematical modeling, calibration, and validation of the sensor along with metrology, statistical inference, and spirometry techniques were used as a base for aquiring scientific knowledge of the system. The system directly measures the variable of interest (air volume) and refers to spirometric techniques in the elaboration of its model. This improves the realism of the dummies during the CPR training, because it estimates, in real-time, not only the volume of air entering in the lungs but also the Forced Vital Capacity (FVC), Forced Expiratory Volume (FEVt) and Medium Forced Expiratory Flow (FEF20–75%). The validation of the sensor achieved results that address the requirements for this application, that is, the error below 3.4% of full scale. During the spirometric tests, the system presented the measurement results of (305 ± 22, 450 ± 23, 603 ± 24, 751 ± 26, 922 ± 27, 1021 ± 30, 1182 ± 33, 1326 ± 36, 1476 ± 37, 1618 ± 45 and 1786 ± 56) × 10−6 m3 for reference values of (300, 450, 600, 750, 900, 1050, 1200, 1350, 1500, 1650 and 1800) × 10−6 m3, respectively. Therefore, considering the spirometry and pressure boundary conditions of the manikin lungs, the system achieves the objective of simulating valid spirometric data for debriefings, that is, there is an agreement between the measurement results when compared to the signal generated by a commercial spirometer (Koko brand). The main advantages that this work presents in relation to the sensors commonly used for this purpose are: (i) the reduced cost, which makes it possible, for the first time, to use a respiratory volume sensor in medical simulators or training dummies; (ii) the direct measurement of air entering the lung using a noninvasive method, which makes it possible to use spirometry parameters to characterize simulated human respiration during the CPR training; and (iii) the measurement of spirometric parameters (FVC, FEVt, and FEF20–75%), in real-time, during the CPR training, to achieve optimal ventilation performance. Therefore, the system developed in this work addresses the minimum requirements for the practice of ventilation in the CPR maneuvers and has great potential in several future applications.

1 October 2017
Verified
Conference Paper
Closed access
MHMarcelo Eustaquio Hamanaka
Marcelo Eustaquio Hamanaka
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
SSSavio Augusto Lopes da Silva
Savio Augusto Lopes da Silva
The use of combustion engines in portable applications has several applications, such as: high-pressure washers, motogenerators, crushers and pumping. However, the autonomy of such equipment does not always follow its advancement in efficiency and robustness. Therefore, the monitoring of the fuel level of these machines is necessary to know about their autonomy. This article refers to the development of a portable capacitive transducer for fuel level measurement, consisting of a plug-in device, easy to install and compact. From its construction and configuration, the device produces a frequency signal inversely proportional to the capacitance variation of the sensor element. The transducer technique is non-invasive and it takes advantage of the tank shell characteristic construction for coupling of the device.