Gabriel Santos

Mr. Gabriel Santos

Universidade Federal de Ouro Preto, Ouro Preto, MG, Brasil.
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
ÉPÉrica Silva Pinto
Érica Silva Pinto
GSGabriel Santos
Gabriel Santos
PMPaulo Monteiro
Paulo Monteiro
The most widely used technique for measuring capacitive impedances (or complex electrical permittivity) is to apply a frequency signal to the sensor and measure the amplitude and phase of the output signal. The technique, although efficient, involves high-speed circuits for phase measurement, especially when the medium under test has high conductivity. This paper presents a sensor to measure complex electrical permittivity based on an alternative approach to amplitude and phase measurement: The application of two distinct frequencies using a current-to-voltage converter circuit based in a transimpedance amplifier, and an 8-bit microcontroller. Since there is no need for phase measurement and the applied frequency is lower compared to the standard method, the circuit presents less complexity and cost than the traditional technique. The main advance presented in this work is the use of mathematical modeling of the frequency response of the circuit to make it possible for measuring the dielectric constant using a lower frequency than the higher cut-off frequency of the system, even when the medium under test has high conductivity (tested up to 1220 μS/cm). The proposed system caused a maximum error of 0.6% for the measurement of electrical conductivity and 2% for the relative dielectric constant, considering measurement ranges from 0 to 1220 μS/cm and from 1 to 80, respectively.

29 April 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
EPErica Silva Pinto
Erica Silva Pinto
GSGabriel Santos
Gabriel Santos
PMPaulo Henrique Vieira Magalhaes
Paulo Henrique Vieira Magalhaes
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
Water content or moisture of materials is a parameter widely used in the industry. In mining, it is an important variable to control in iron ore production. High moistures may cause instability of iron ore piles and may make transport by ship unfeasible. Therefore, this paper presents the development of a system for measuring iron ore moisture on a conveyor belt (laboratory-scale). The structure that supports the sensor has two degrees of freedom, which allow perpendicular and parallel movements. The parallel movement makes the relative velocity between the measurement cell and the ore almost zero. The vertical movement allows the sensor to be placed at different depths in the ore. These sets enable real-time and in situ measurements. The system uses the capacitive method to determine the dielectric constant of the iron ore located between the sensor electrodes and, consequently, the moisture. This system has a measuring range of 0 to 14% on a dry basis and presents an uncertainty up to 0.07 percentage points for a 2-standard-deviation confidence level. In the validation process, the absolute error was less than 0.34 percentage point in the mining interest range of 6 to 14%. The founded results achieve a significant advance in the development of real-time equipment for measuring ore moisture since there is no device capable of doing it with the necessary level of accuracy and precision. For mining, this kind of system represents a big step to take corrective and preventive decisions around iron ore moisture control.

1 April 2023 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
GSGabriel Santos
Gabriel Santos
ÉPÉrica Pinto
Érica Pinto
ASArtur Silva
Artur Silva
PMPaulo Monteiro
Paulo Monteiro
André Luiz Amarante MesquitaAndré Luiz Amarante Mesquita
André Luiz Amarante Mesquita
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
The emission of particulates during rail transport is related to the low moisture of the ore, which causes environmental pollution along the railroad. Given this problem, this work proposes the development of a parallel plate capacitive sensor applied to a small wagon prototype made of acrylic to measure the iron ore moisture and support studies of particulate emissions carried out in a laboratory. The sensor uses the Real-Dual Frequency method, which decreases the influence of electrical conductivity on the dielectric constant, even using low frequency (up to 8 MHz). From the dielectric constant, iron ore moisture is determined from indirect calibration, which obtained an accuracy of 0.07 pp and a maximum error of 0.39 pp. This study shows the development of an innovative real-time capacitive sensor, which uses a modern impedance-based technique to investigate particulate emissions and the drying behavior of iron ore

19 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ASAlan Kardek Rêgo Segundo
Alan Kardek Rêgo Segundo
ÉPÉrica Silva Pinto
Érica Silva Pinto
GSGabriel Santos
Gabriel Santos
PMPaulo Monteiro
Paulo Monteiro
There was two errors in the original article