The Arterial Pressure Waveform (APW) can provide essential information about arterial wall integrity and arterial stiffness. Most of APW analysis frameworks individually process each hemodynamic parameter and do not evaluate inter-dependencies in the overall pulse morphology. The key contribution of this work is the use of machine learning algorithms to deal with vectorized features extracted from APW. With this purpose, we follow a five-step evaluation methodology: (1) a custom-designed, non-invasive, electromechanical device was used in the data collection from 50 subjects; (2) the acquired position and amplitude of onset, Systolic Peak (SP), Point of Inflection (Pi) and Dicrotic Wave (DW) were used for the computation of some morphological attributes; (3) pre-processing work on the datasets was performed in order to reduce the number of input features and increase the model accuracy by selecting the most relevant ones; (4) classification of the dataset was carried out using four different machine learning algorithms: Random Forest, BayesNet (probabilistic), J48 (decision tree) and RIPPER (rule-based induction); and (5) we evaluate the trained models, using the majority-voting system, comparatively to the respective calculated Augmentation Index (AIx). Classification algorithms have been proved to be efficient, in particular Random Forest has shown good accuracy (96.95%) and high area under the curve (AUC) of a Receiver Operating Characteristic (ROC) curve (0.961). Finally, during validation tests, a correlation between high risk labels, retrieved from the multi-parametric approach, and positive AIx values was verified. This approach gives allowance for designing new hemodynamic morphology vectors and techniques for multiple APW analysis, thus improving the arterial pulse understanding, especially when compared to traditional single-parameter analysis, where the failure in one parameter measurement component, such as Pi, can jeopardize the whole evaluation.
31 January 2013 in Cardiovascular Engineering and Technology
Local pulse-wave velocity (PWV) is an accurate indicator of the degree of arteriosclerosis (stiffness) in an artery, providing a direct characterization of the properties of its wall. Devices currently available for local PWV measurement are mainly based on ultrasound systems and have not yet been generalized to clinical practice since they require high technical expertise and most of them are limited in precision, due to the lack of reliable signal processing methods. The present work describes a new type of probe, based on a double-headed piezoelectric (PZ) sensor. The principle of PWV measurement involves determination of the pulse transit time between the signals acquired simultaneously by both PZs, placed 23 mm apart. The double probe (DP) characterization is accomplished in three main studies, carried out in a dedicated test bench system, capable of reproducing a range of clinically relevant properties of the cardiovascular system. The first study refers to determination of the impulse response (IR) for each PZ sensor, whereas the second one explores the existence of crosstalk between both transducers. In the last one, DP time resolution is inferred from a set of three different algorithms based on (a) the maximum of cross-correlation function, (b) the maximum amplitude detection and (c) the zero-crossing point identification. These values were compared with those obtained by the reference method, which consists of the simultaneous acquisition of pressure waves by means of two pressure sensors. The new probe demonstrates good performance on the test bench system and results show that the signals do not exhibit crosstalk. A good agreement was also verified between the PWV obtained from the DP signals (19.55 ± 2.02 ms(-1)) and the PWV determined using the reference method (19.26 ± 0.04 ms(-1)). Although additional studies are still required, this probe seems to be a valid alternative to local PWV stand-alone devices.
1 November 2014 in Computer Methods and Programs in Biomedicine
A new type of optical probe based on laser Doppler self-mixing technology, for a truly non-contact measurement in a single location, and extraction of the temporal features of the distension wave in the arterial wall, was developed. The monitoring of temporal features allows the assessment of cardiovascular function when measurement is carried out at the carotid artery. An algorithm based on the short-time Fourier transform and empirical mode decomposition was applied to the test setup self-mixing signals for the determination of waveform features, with an accuracy of a few milliseconds and a root mean square error less than 3 ms. In vivo testing signals show great consistency in the measured pulse pressure waveform.