Tânia Pereira

Ms. Tânia Pereira


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2020 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
TPTânia Pereira
Tânia Pereira
NTNate Tran
Nate Tran
KGKais Gadhoumi
Kais Gadhoumi
MPMichele M. Pelter
Michele M. Pelter
DDDuc H. Do
Duc H. Do
XHXiao Hu
Xiao Hu
Atrial fibrillation (AF) is a cardiac rhythm disorder associated with increased morbidity and mortality. It is the leading risk factor for cardioembolic stroke and its early detection is crucial in both primary and secondary stroke prevention. Continuous monitoring of cardiac rhythm is today possible thanks to consumer-grade wearable devices, enabling transformative diagnostic and patient management tools. Such monitoring is possible using low-cost easy-to-implement optical sensors that today equip the majority of wearables. These sensors record blood volume variations—a technology known as photoplethysmography (PPG)—from which the heart rate and other physiological parameters can be extracted to inform about user activity, fitness, sleep, and health. Recently, new wearable devices were introduced as being capable of AF detection, evidenced by large prospective trials in some cases. Such devices would allow for early screening of AF and initiation of therapy to prevent stroke. This review is a summary of a body of work on AF detection using PPG. A thorough account of the signal processing, machine learning, and deep learning approaches used in these studies is presented, followed by a discussion of their limitations and challenges towards clinical applications.

14 October 2015 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
TPTânia Pereira
Tânia Pereira
CCCarlos Correia
Carlos Correia
JCJoão Cardoso
João Cardoso
The great incidence of cardiovascular (CV) diseases in the world spurs the search for new solutions to enable an early detection of pathological processes and provides more precise diagnosis based in multi-parameters assessment. The pulse wave velocity (PWV) is considered one of the most important clinical parameters for evaluate the CV risk, vascular adaptation, and therapeutic efficacy. Several studies were dedicated to find the relationship between PWV measurement and pathological status in different diseases, and proved the relevance of this parameter. The commercial devices dedicate to PWV estimation make a regional assessment (measured between two vessels), however a local measurement is more precise evaluation of artery condition, taking into account the differences in the structure of arteries. Moreover, the current devices present some limitations due to the contact nature. Emerging trends in CV monitoring are moving away from more invasive technologies to non-invasive and non-contact solutions. The great challenge is to explore the new instrumental solutions that allow the PWV assessment with fewer approximations for an accurately evaluation and relatively inexpensive techniques in order to be used in the clinical routine.

1 November 2023 in Physiological Measurement
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
John AllenJohn Allen
John Allen
Raquel BailónRaquel Bailón
Raquel Bailón
SBStephanie Baker
Stephanie Baker
JBJoachim A Behar
Joachim A Behar
TZTingting Zhu
Tingting Zhu
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.

1 September 2017 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
TPTânia Pereira
Tânia Pereira
PAPedro R Almeida
Pedro R Almeida
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
AAAna Aguiar
Ana Aguiar

16 April 2021 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
CFCláudia Freitas
Cláudia Freitas
CSCatarina Sousa
Catarina Sousa
FMFrancisco Machado
Francisco Machado
MSMariana Serino
Mariana Serino
VSVanessa Santos
Vanessa Santos
VHVenceslau Hespanhol
Venceslau Hespanhol
Liquid biopsy is an emerging technology with a potential role in the screening and early detection of lung cancer. Several liquid biopsy-derived biomarkers have been identified and are currently under ongoing investigation. In this article, we review the available data on the use of circulating biomarkers for the early detection of lung cancer, focusing on the circulating tumor cells, circulating cell-free DNA, circulating micro-RNAs, tumor-derived exosomes, and tumor-educated platelets, providing an overview of future potential applicability in the clinical practice. While several biomarkers have shown exciting results, diagnostic performance and clinical applicability is still limited. The combination of different biomarkers, as well as their combination with other diagnostic tools show great promise, although further research is still required to define and validate the role of liquid biopsies in clinical practice.

3 April 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
TPTânia Pereira
Tânia Pereira
KGKais Gadhoumi
Kais Gadhoumi
MMMitchell Ma
Mitchell Ma
XLXiuyun Liu
Xiuyun Liu
Ran XiaoRan Xiao
Ran Xiao
XHXiao Hu
Xiao Hu
Early detection of Atrial Fibrillation (AFib) is crucial to prevent stroke recurrence. New tools for monitoring cardiac rhythm are important for risk stratification and stroke prevention. As many of new approaches to longterm AFib detection are now based on photoplethysmogram (PPG) recordings from wearable devices, ensuring high PPG signal-to-noise ratios is a fundamental requirement for a robust detection of AFib episodes. Traditionally, signal quality assessment is often based on the evaluation of similarity between pulses to derive signal quality indices. There are limitations to using this approach for accurate assessment of PPG quality in the presence of arrhythmia, as in the case of AFib, mainly due to substantial changes in pulse morphology. In this paper, we first tested the performance of algorithms selected from a body of studies on PPG quality assessment using a dataset of PPG recordings from patients with AFib. We then propose machine learning approaches for PPG quality assessment in 30-s segments of PPG recording from 13 stroke patients admitted to the University of California San Francisco (UCSF) neuro intensive care unit and another dataset of 3764 patients from one of the five UCSF general intensive care units. We used data acquired from two systems, fingertip PPG (fPPG) from a bedside monitor system, and radial PPG (rPPG) measured using a wearable commercial wristband. We compared various supervised machine learning techniques including knearest neighbors, decisions trees, and a two-class support vector machine (SVM). SVM provided the best performance. fPPG signals were used to build the model and achieved 0.9477 accuracy when tested on the data from the fPPG exclusive to the test set, and 0.9589 accuracy when tested on the rPPG data.