Introduction: Cochlear implants (CIs) provide access to sound and help mitigate the negative effects of hearing loss. As a field, we are successfully implanting more adults with greater amounts of residual hearing than ever before. Despite this, utilization remains low, which is thought to arise from barriers that are both intrinsic and extrinsic. A considerable body of literature has been published in the last 5 years on barriers to adult CI uptake, and understanding these barriers is critical to improving access and utilization. This scoping review aims to summarize the existing literature and provide a guide to understanding barriers to adult CI uptake. Methods: Inclusion criteria were limited to peer-reviewed articles involving adults, written in English, and accessible with a university library subscription. A cutoff of 20 years was used to limit the search. Barriers uncovered in this review were categorized into an ecological framework. Results: The initial search revealed 2,315 items after duplicates were removed. One hundred thirty-one articles were reviewed under full-text, and 68 articles met the inclusion criteria. Discussion: Race, ethnicity, and reimbursement are policy and structural barriers. Public awareness and education are societal barriers. Referral and geographical challenges are forms of organizational barriers. Living context and professional support are interpersonal barriers. At the individual level, sound quality, uncertainty of outcome, surgery, loss of residual hearing, and irreversibility are all barriers to CI uptake. By organizing barriers into an ecological framework, targeted interventions can be used to overcome such barriers.
Speech that has been artificially accelerated through time compression produces a notable deficit in recall of the speech content. This is especially so for adults with cochlear implants (CI). At the perceptual level, this deficit may be due to the sharply degraded CI signal, combined with the reduced richness of compressed speech. At the cognitive level, the rapidity of time-compressed speech can deprive the listener of the ordinarily available processing time present when speech is delivered at a normal speech rate. Two experiments are reported. Experiment 1 was conducted with 27 normal-hearing young adults as a proof-of-concept demonstration that restoring lost processing time by inserting silent pauses at linguistically salient points within a time-compressed narrative (“time-restoration”) returns recall accuracy to a level approximating that for a normal speech rate. Noise vocoder conditions with 10 and 6 channels reduced the effectiveness of time-restoration. Pupil dilation indicated that additional effort was expended by participants while attempting to process the time-compressed narratives, with the effortful demand on resources reduced with time restoration. In Experiment 2, 15 adult CI users tested with the same (unvocoded) materials showed a similar pattern of behavioral and pupillary responses, but with the notable exception that meaningful recovery of recall accuracy with time-restoration was limited to a subgroup of CI users identified by better working memory spans, and better word and sentence recognition scores. Results are discussed in terms of sensory-cognitive interactions in data-limited and resource-limited processes among adult users of cochlear implants.
Background/Objectives: We investigated: (1) differences in CI-aided thresholds and speech perception scores among cochlear implant manufacturers and (2) the relationship between CI-aided thresholds and speech perception. Methods: We analyzed exploratory data from NYU and a confirmatory data set of 120 CI-aided audiograms from the ASAN clinic. CI-aided soundfield evaluations were compared between manufacturers (Cochlear, Advanced Bionics, MED-EL) using 5- and 6-pure-tone average thresholds; percentage of patients with average thresholds above 35 dB HL; speech perception scores; and correlations between thresholds and speech perception. Results: Compared to Cochlear users, MED-EL and Advanced Bionics users had significantly higher (poorer) pure-tone averages (26.7 dB HL for Cochlear vs. 30.0 dB HL for AB and 34.6 dB HL for MED-EL at NYU; 29.0 dB HL for Cochlear vs. 36.5 dB HL for MED-EL at ASAN), and higher incidence of 5- or 6-PTAs above 35 dB HL (1.6% vs. 23.4%/47.1% at NYU; 11.2% vs. 60.0% at ASAN). Word and sentence scores were significantly higher for the Cochlear group when compared to the MED-EL group. Speech scores were higher for manufacturers that recommend the use of behaviorally-measured T-levels (Cochlear) rather than estimated T-levels (AB and MED-EL). Significant negative correlations existed between CI-aided thresholds and speech scores. Conclusions: Significant differences in CI-aided thresholds and speech perception were observed between manufacturers, potentially related to brand-specific T-level programming approaches.
Introduction Cochlear Implants (CIs) provide access to sound and help mitigate the negative effects of hearing loss. As a field, we are successfully implanting more adults with greater amounts of residual hearing than ever before. Despite this, utilization remains low, which is thought to arise from barriers that are both intrinsic and extrinsic. A considerable body of literature has been published in the last five years on barriers to adult CI uptake, and understanding these barriers is critical to improving access and utilization. This scoping review aims to summarize the existing literature and provide a guide to understanding barriers to adult CI uptake. Methods Inclusion criteria were limited to peer-reviewed articles involving adults, written in English, and accessible with a university library subscription. A cutoff of 20 years was used to limit the search. Barriers uncovered in this review were categorized into an ecological framework. Results The initial search revealed 2,315 items after duplicates were removed. One hundred thirty-one articles were reviewed under full-text, and 68 articles met inclusion criteria. Discussion Race, ethnicity, and reimbursement are policy and structural barriers. Public awareness and education are societal barriers. Referral and geographical challenges are forms of organizational barriers. Living context and professional support are interpersonal barriers. At the individual level sound quality, uncertainty of outcome, surgery, loss of residual hearing, and irreversibility are all barriers to CI uptake. By organizing barriers into an ecological framework, targeted interventions can be used to overcome such barriers.
Objectives: The purpose of this pilot study was to investigate (1) if the Speech Intelligibility Index (SII) could be used to identify ears that meet cochlear implant (CI) candidacy beyond the "60/60" referral guidelines and (2) investigate the relationship between SII from patients' own hearing aids (HAs) and SII from optimally fit clinic-stock HAs such that a patient's own HAs can act as a proxy for an optimally fit HA and thus as a referral metric. Design: Prospective study of 23 participants (≥ 18 years) with bilateral moderate to profound sensorineural hearing loss who were CI candidates in at least one ear. SII-Clinic (SII-C) values were recorded with probe-microphone measures using a Verifit II device (NAL-N2 targets) with speech stimuli presented at 60 dB A during patient CI evaluation in either their own HAs or clinic-stock HAs. SII values from participants' own HAs were recorded as part of a larger research protocol, thus SII-Personal (SII-P), with probe-microphone measures using a Verifit I device (NAL-RP targets) with pink noise stimuli presented at 65 dB A. Participants that did not wear HAs did not have SII-P calculated. Data was collapsed across ears. Correlation analysis between SII and best-aided consonant-nucleus-consonant (CNC) was conducted. Benchmark SII values were extrapolated using a best-fit line and CI candidacy rates reflecting various aided CNC scores that could be applied across CI centers. Nested logistic regression models were used to determine if the SII-C could improve model fit beyond the revised ear-specific 60/60 referral guideline. The relationship between SII-C and SII-P was assessed with Wilcoxon signed-rank test and Spearman correlation. Results: Correlation between SII-C and aided CNC score was r = 0.82 (p < 0.001), and the correlation between SII-P and aided CNC was r = 0.46 (p = 0.014). Extrapolated benchmarks of SII were calculated based on different CNC candidacy cutoffs, and benchmarks were able to capture at least 83% of the ears that met CNC candidacy cutoffs. SII was also found to improve model fit with word recognition score (WRS) and pure tone average (PTA) for 60% CNC candidacy cutoff (χ 2 = 9.7; p = 0.002) and increased discrimination (AUC = 0.89 to AUC = 0.99). There was no significant difference between SII-C and SII-P using the Wilcoxon signed-rank test (p = 0.559). Conclusions: A larger study is needed that includes more ears that do not qualify for a CI; however, the results of this study demonstrate that (1) SII has the potential to be used in conjunction with the 60/60 referral guideline for CI candidacy evaluations and (2) SII can be used as a marker of audibility across different devices, including patients' own HAs, making SII an accessible metric during HA fittings and fine tunings.