This article presents a low noise and wide linear dynamic 20-channel analog front-end (AFE) array for frequency-modulated continuous-wave (FMCW) light detection and ranging (LiDAR) system. Each channel of the AFE array mainly consists of a shunt feedback transimpedance amplifier (SF-TIA) with a dc cancellation loop (DCL), a post amplifier, and an output buffer. The DCL is proposed to eliminate the dc current, comprising the dc current sunk to ground (dc-STG) and the dc current sourced from power supply (dc-SFP). In addition, the post amplifier, cascaded with an operational transconductance amplifier (OTA) and an SF-TIA, is proposed to decouple the relationship between gain and output common voltage, achieving both large gain and large output swing. Furthermore, the equalization technique is adopted to expand the bandwidth of the AFE array. The AFE array was implemented and fabricated in a 0.18- $\mu $ m CMOS technology. Measurement results show that the AFE array achieves the maximum transimpedance gain of 107 dB and eliminates the dc current between $-$ 150 and 250 $\mu $ A. With the maximum transimpedance gain, the measured bandwidth, the equivalent input-referred rms noise current, and the signal-to-crosstalk ratio (SCR) between adjacent channels are 165 MHz, 29.4 nArms, and $-$ 33.9 dB, respectively. The AFE array also achieves a linear dynamic range (DR) of 66 dB and the area of each channel is approximately equal to 0.16 $\times$ 1.3 mm $^{2}$ .
Frequency-modulated continuous-wave (FMCW) LiDAR systems are extensively utilized in industrial metrology, autonomous navigation, and geospatial sensing due to their high precision and resilience to interference. However, the intrinsic nonlinear dynamics of laser systems introduce significant distortion, adversely affecting measurement accuracy. Although conventional iterative pre-distortion correction methods can effectively mitigate nonlinearities, their long-term reliability is compromised by factors such as temperature-induced drift and component aging, necessitating periodic recalibration. In light of recent advances in artificial intelligence, deep reinforcement learning (DRL) has emerged as a promising approach to adaptive nonlinear compensation. By continuously interacting with the environment, DRL agents can dynamically modify correction strategies to accommodate evolving system behaviors. Nonetheless, existing DRL-based methods often exhibit limited adaptability in rapidly changing nonlinear contexts and are constrained by inefficient uniform experience replay mechanisms that fail to emphasize critical learning samples. To address these limitations, this study proposes an enhanced Soft Actor-Critic (SAC) algorithm incorporating a hybrid prioritized experience replay framework. The prioritization mechanism integrates modulation frequency (MF) error and temporal difference (TD) error, enabling the algorithm to dynamically reconcile short-term nonlinear perturbations with long-term optimization goals. Furthermore, a time-varying delayed experience (TDE) injection strategy is introduced, which adaptively modulates data storage intervals based on the rate of change in modulation frequency error, thereby improving data relevance, enhancing sample diversity, and increasing training efficiency. Experimental validation demonstrates that the proposed method achieves superior convergence speed and stability in nonlinear correction tasks for FMCW LiDAR systems. The residual nonlinearity of the upward and downward frequency sweeps was reduced to and , respectively, with a spatial resolution of 0.0203m. These results underscore the effectiveness of the proposed approach in advancing intelligent calibration methodologies for LiDAR systems and highlight its potential for broad application in high-precision measurement domains.
Frequency modulated continuous wave (FMCW) laser ranging has emerged as a novel high-precision distance measurement technique with low laser power, high safety, and strong anti-interference ability. Traditional frequency-modulated continuous wave (FMCW) laser ranging methods highly rely on complex digital signal processing, particularly using analog-to-digital converters (ADCs) and fast Fourier transforms (FFTs) on field-programmable gate arrays (FPGAs). This approach can be costly and resource-intensive due to the high sampling rates and extensive logic resources required, especially as demand for higher speed and accuracy increases in applications like LiDAR and real-time metrology. In contrast, the proposed method uses a simpler, lower-cost pulse counting technique instead of ADCs and FFTs. By converting the intermediate frequency (IF) signal directly into pulses through comparators and tallying these pulses, this approach measures frequency more efficiently. Additional processing overcomes traditional pulse counting limitations in handling continuously varying frequencies, achieving high accuracy with fewer resources. Experimental results show this method delivers precise measurements with a minimal setup, achieving an error margin within 10 cm at ranges from 0.5 to 10 meters and a root mean square error below 0.71 cm. This innovation is well-suited for developing affordable, high-precision indoor FMCW laser ranging systems.
Frequency-modulated continuous-wave (FMCW) LiDAR systems frequently experience noise interference during multi-target measurements in real-world applications, resulting in target overlapping and diminished detection accuracy. Conventional denoising approaches—such as Empirical Mode Decomposition (EMD) and wavelet thresholding—are often constrained by challenges like mode mixing and the attenuation of weak target signals, which limits their detection precision. To address these limitations, this study presents a novel denoising framework that integrates an optimized Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (CEEMDAN) algorithm and singular value decomposition (SVD). The CEEMDAN algorithm’s two critical parameters—the noise standard deviation and the number of noise additions—are optimally determined using particle swarm optimization (PSO), with the envelope entropy of the intrinsic mode functions (IMFs) serving as the fitness criterion. IMFs are subsequently selected based on spectral and amplitude comparisons with the original signal to facilitate initial signal reconstruction. Following CEEMDAN-based decomposition, SVD is employed with a normalized soft thresholding technique to further suppress residual noise. Validation using both synthetic and experimental datasets demonstrates the superior performance of the proposed approach over existing methods in multi-target scenarios. Specifically, it reduces the root mean square error (RMSE) by 45% to 59% and the mean square error (MSE) by 34% to 69%, and improves the signal-to-noise ratio (SNR) by 1.85–4.38 dB and the peak signal-to-noise ratio (PSNR) by 1.18–6.94 dB. These results affirm the method’s effectiveness in enhancing signal quality and target distinction in noisy FMCW LiDAR measurements.