Costanza Aricò

Prof. Dr. Costanza Aricò

University of Palermo (Palermo, Italy)
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2013 in Energies
Verified
Journal Article
Open access
PDF file
VSVincenzo Sammartano
Vincenzo Sammartano
Costanza AricòCostanza Aricò
Costanza Aricò
Armando CarravettaArmando Carravetta
Armando Carravetta
Oreste FecarottaOreste Fecarotta
Oreste Fecarotta
Tullio TucciarelliTullio Tucciarelli
Tullio Tucciarelli
In hydropower, the exploitation of small power sources requires the use of small turbines that combine efficiency and economy. Banki-Michell turbines represent a possible choice for their simplicity and for their good efficiency under variable load conditions. Several experimental and numerical tests have already been designed for examining the best geometry and optimal design of cross-flow type machines, but a theoretical framework for a sequential design of the turbine parameters, taking full advantage of recently expanded computational capabilities, is still missing. To this aim, after a review of the available criteria for Banki-Michell parameter design, a novel two-step procedure is described. In the first step, the initial and final blade angles, the outer impeller diameter and the shape of the nozzle are selected using a simple hydrodynamic analysis, based on a very strong simplification of reality. In the second step, the inner diameter, as well as the number of blades and their shape, are selected by testing single options using computational fluid dynamics (CFD) simulations, starting from the suggested literature values. Good efficiency is attained not only for the design discharge, but also for a large range of variability around the design value.

4 November 2014 in Water Resources Management
Verified
Journal Article
Open access
PDF file
Oreste FecarottaOreste Fecarotta
Oreste Fecarotta
Costanza AricòCostanza Aricò
Costanza Aricò
Armando CarravettaArmando Carravetta
Armando Carravetta
Riccardo MartinoRiccardo Martino
Riccardo Martino
HRHelena Ramos
Helena Ramos
Pressure control is one of the main techniques to control leakages in Water Distribution Networks (WDNs) and to prevent pipe damage, improving the delivery standards of a water supply systems. Pressure reducing stations (PRSs) equipped by either pressure reducing valves or motor driven regulating valves are commonly used to dissipate excess hydraulic head in WDNs. An integrated new technical solution with economic and system flexibility benefits is presented which replaces PRSs with pumps used as turbines (PATs). Optimal PAT performance is obtained by a Variable Operating Strategy (VOS), recently developed for the design of small hydropower plants on the basis of valve time operation, and net return determined by both energy production and savings through minimizing leakage. The literature values of both leakages costs and energy tariffs are used to develop a buisness plan model and evaluate the economic benefit of small hydropower plants equipped with PATs. The study shows that the hydropower installation produces interesting economic benefits, even in presence of small available power, that could encourage the leakage reduction even if water savings are not economically relevant, with consequent environmental benefits.

1 November 2011 in Advances in Water Resources
Verified
Journal Article
Closed access
Costanza AricòCostanza Aricò
Costanza Aricò
MSM. Sinagra
M. Sinagra
LBL. Begnudelli
L. Begnudelli
Tullio TucciarelliTullio Tucciarelli
Tullio Tucciarelli

1 August 2009 in Advances in Water Resources
Verified
Journal Article
Closed access
Costanza AricòCostanza Aricò
Costanza Aricò
CNCarmelo Nasello
Carmelo Nasello
Tullio TucciarelliTullio Tucciarelli
Tullio Tucciarelli

1 October 2021 in Ocean Engineering
Verified
Journal Article
Closed access
Mabrouk MosbahiMabrouk Mosbahi
Mabrouk Mosbahi
MLMariem Lajnef
Mariem Lajnef
MDMouna Derbel
Mouna Derbel
BMBouzid Mosbahi
Bouzid Mosbahi
ZDZied Driss
Zied Driss
TTTullio Tucciarelli
Tullio Tucciarelli

2 March 2021 in Water
Verified
Journal Article
Open access
PDF file
Amir GhaderiAmir Ghaderi
Amir Ghaderi
MDMehdi Dasineh
Mehdi Dasineh
Francesco AristodemoFrancesco Aristodemo
Francesco Aristodemo
Costanza AricòCostanza Aricò
Costanza Aricò
The submerged hydraulic jump is a sudden change from the supercritical to subcritical flow, specified by strong turbulence, air entrainment and energy loss. Despite recent studies, hydraulic jump characteristics in smooth and rough beds, the turbulence, the mean velocity and the flow patterns in the cavity region of a submerged hydraulic jump in the rough beds, especially in the case of triangular macroroughnesses, are not completely understood. The objective of this paper was to numerically investigate via the FLOW-3D model the effects of triangular macroroughnesses on the characteristics of submerged jump, including the longitudinal profile of streamlines, flow patterns in the cavity region, horizontal velocity profiles, streamwise velocity distribution, thickness of the inner layer, bed shear stress coefficient, Turbulent Kinetic Energy (TKE) and energy loss, in different macroroughness arrangements and various inlet Froude numbers (1.7 < Fr1 < 9.3). To verify the accuracy and reliability of the present numerical simulations, literature experimental data were considered.