Ghada Abdelfattah Hussein

Dr. Ghada Abdelfattah Hussein


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2025 in Odontology
Verified
Journal Article
Open access
PDF file
Nour Abdelrady Mohammed AbdelmohsenNour Abdelrady Mohammed Abdelmohsen
Nour Abdelrady Mohammed Abdelmohsen
MWMarwa Wahsh
Marwa Wahsh
MZMaged Zohdy
Maged Zohdy
GHGhada Abdelfattah Hussein
Ghada Abdelfattah Hussein
AAAbdulaziz Alhotan
Abdulaziz Alhotan
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
To compare experimentally the failure modes of endodontically treated teeth restored with custom-made polyetheretherketone (PEEK) post–core (milled and pressed) to those restored with the standard technique of customized fiberglass posts with composite cores, and to analyze numerically stress distribution patterns in each system using the finite element analysis (FEA). Experimentally, 21 mandibular premolars were endodontically treated, prepared for post-restoration, mounted in resin mold, decapitated, and assigned to three groups: M (milled PEEK), P (pressed PEEK), and C (control group; ready-made fiberglass posts customized with resin composite). All post–core restorations were cemented and subjected to thermocycling. Failure modes were visually evaluated after fracture by means of a universal testing machine. Numerically, stress analysis was assessed using FEA, based on digital models designed to replicate the experimental setup. Milled PEEK posts showed a uniformly favorable failure mode across all specimens (100%), whereas pressed PEEK and customized fiberglass posts displayed more variable failure modes, yet with a higher proportion of favorable outcomes. Numerically, the highest VME stress values were in the cervical half of the post area (up to 62.7 MPa), with minimal differences between milled and pressed PEEK posts. PEEK posts had greater stress concentrations in the cervical area of the post area, while fiberglass posts showed slightly higher stress in the middle and apical areas. Custom-made milled and pressed PEEK posts are effective for restoring endodontically treated teeth, with milled PEEK posts showing the most favorable failure mode and stress distribution pattern.

1 October 2020 in Egyptian Dental Journal
Verified
Journal Article
Closed access
PDF file
GHGhada Abdelfattah Hussein
Ghada Abdelfattah Hussein
NWNourhan Wagdy
Nourhan Wagdy
MNMohamed Nasser
Mohamed Nasser
Purpose: The aim of this study was to evaluate the effect of different bleaching protocols on biaxial flexural strength and micro hardness of two ceramic materials. Material and Methods: A total of 112 discs, 56 discs of each material, were prepared from Celtra® Duo and VITA ENAMIC® with 10mm diameter and 1.2mm thickness. Each material was divided into 4 groups (n=14) according to the bleaching protocol done: Group 1 Control group “no bleaching”, Group 2 home bleaching “Carbamide Peroxide 22%”, Group 3 home bleaching “Hydrogen Peroxide 14%” and Group 4 In-office bleaching using diode Laser. For each material, half the number of discs in each group (n=7) were subjected to Biaxial Flexural Test using Universal Testing Machine Instron-3345 together with Instron BlueHill® universal software, while the other half was subjected to Micro-Hardness Test using Tukon™ 1102 Wilson® Hardness Tester. Data was represented by mean and standard deviation (SD) values. Two-way ANOVA was used to study the effect of different tested variables and their interaction on biaxial flexural strength (Mpa) and micro-hardness, The significance level was set at p ≤0.05 within all tests. Statistical analysis was performed with IBM® SPSS® Statistics Version 26 for Windows. Results: For Biaxial Flexural Strength and Micro-hardness; Celtra duo samples had a significantly higher value than samples made with Vita Enamic for all bleaching groups. Conclusion: Bleaching resulted in a significant diminution for both biaxial flexural strength and surface micro-hardness of Celtra Duo and Vita Enamic.

1 January 2021 in Al-Azhar Journal of Dental Science
Verified
Journal Article
Closed access
PDF file
GHGhada Abdelfattah Hussein
Ghada Abdelfattah Hussein
NGNorbert Gutknecht
Norbert Gutknecht
TSTalaat Samhan
Talaat Samhan
AYAhmed Ibrahim Youssef
Ahmed Ibrahim Youssef
The purpose The purpose of this study was to evaluate the debonding of feldspathic and lithium disilicate reinforced glass ceramic veneers using Erbium lasers with two different curing mode resin cement.] Materials and Methods: In this study, a total of 80 ceramic specimens were used. They were divided into two groups (n= 40/group) according to ceramic material used into: Group (A) lithium disilicate (IPS Emax), Group (B) Feldspathic porcelain. (VITA MARK II). Each group was further subdivided into two subgroups according to the cement curing mode (n= 20/subgroup): Subgroup (L) Light cured resin cement, Subgroup (D) Dual cured resin cement. Er,Cr:YSGG (turbo handpiece) was used on all subgroups. Scanning electron microscope and Profilometer were used to evaluate surface tomography & roughness. Data was analyzed statistically. Results: For surface roughness of two ceramics at base line and after debonding .There was no statistically significant difference between median (Ra) values of the two ceramics (P-value=0.754, Effect size=0.199), (P-value= 0.825, Effect size=0.155) and (P-value=0.117, Effect size=0.245). As for the curing mode: both materials showed no statistically significant effect of curing modes (P-value = 0.425, Effect size = 0.051) and (P-value = 0.543, Effect size = 0.065), respectively. Conclusion: Based on the limitation of the current study ; the following conclusions can be drawn: -Er, Cr: YSGG fluid dynamic laser system is an effective clinical application for the debonding of resin-bonded all-ceramic restorations. - the surface topography of both ceramic materials almost the same after debonding which make their future use possible

1 October 2020 in Egyptian Dental Journal
Verified
Journal Article
Closed access
PDF file
GHGhada Abdelfattah Hussein
Ghada Abdelfattah Hussein
APurpose : the study was designed to evaluate the trueness of two premolar endocrowns preparation design with different virtual impression techniques Material and methods: Two premolar teeth were endodontically treated, prepared using a CNC machine. Tooth A was prepared to have a flat occlusal surface, while tooth B was prepared to have a 45º cusp anatomy inclination. For each tooth, a total of 40 different impressions were obtained. They were divided into 4 groups (n=10) as follows: Group 1; direct scan using Medit i500, group 2; direct scan using trios 3shape, group 3; Putty and light impression were taken and impression was scanned using Identica Hybrid, group 4; Impressions were poured in gypsum and tooth model was scanned using identica hybrid. Both CAD reference models and all (STL) files (n=80) were loaded into a 3D reverse engineering software (Geomagic QualifyTM 2012, Geomagic, Morrisville, USA). By using this method, for each superimposition, the deviation at each measurement point was recorded as a root mean square. Results : There statistically significant differences between different groups. Anatomical reductions showed statistically significant higher trueness when compared to flat occlusal reduction. As for impression method, no statistically significant differences between direct Trios 3Shape scanning and impression scanning. However, both showed higher trueness when compared to direct Medit i500 scanning and cast scanning. Conclusion : Anatomical preparation can be reproduced more accurately than flat preparation. Scanning direct impression produce more accurate virtual impression.

1 January 2021 in Egyptian Dental Journal
Verified
Journal Article
Closed access
PDF file
GHGhada Abdelfattah Hussein
Ghada Abdelfattah Hussein
TSTarek Salah
Tarek Salah
DADina Afifi
Dina Afifi
Objective: The purpose of this study was to evaluate the effect of MDP containing resin cement and surface treatment of Translucent zirconia and Ultra translucent zirconia on shear bond strength. Material & Methods: Eighty zirconia discs were constructed . Samples were divided into two groups: Group I: Translucent zirconia samples (n=20) Gro up II: Ultra translucent zirconia samples (n=20) Each group will be subdivided into 2 subgroups according to the surface treatment Subgroup A: Samples will be treated with air abrasion Sub group B: Samples will be left untreated. Each sub group will be further subdivided into 2 subgroups according to bond type: Subgroup 1: samples cemented with MDP containing bond (Universal bond). Subgroup 2: samples cemented with non MDP containing bond (Adper single bon II). All tested samples were subjected to Shear bond strength test.Deboneded samples were examined under the scan electron microscope to determine their mode of failure.Data were statistically analyzed and recorded. Results: Regarding the effect of ceramic material and resin cement :For MDP containing resin cement, translucent zirconia had a significantly higher value than ultra translucent zirconia. While for Non-MDP containing resin cement there was no significant difference between both materials. Regarding the effect of surface treatment and resin cement for both treated and untreated samples, MDP containing resin cement had a significantly higher value than Non-MDP containing resin cement. Conclusion: the use of phosphate monomer luting cements on freshly air-abraded zirconia as the simplest and most effective way for zirconia cementation procedure.