Abdulaziz Alhotan

Dr. Abdulaziz Alhotan

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
SZSaleh Zidan
Saleh Zidan
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
AAAbdulaziz Alhotan
Abdulaziz Alhotan
Julfikar HaiderJulfikar Haider
Julfikar Haider
JYJulian Yates
Julian Yates
Acrylic resin PMMA (poly-methyl methacrylate) is used in the manufacture of denture bases but its mechanical properties can be deficient in this role. This study investigated the mechanical properties (flexural strength, fracture toughness, impact strength, and hardness) and fracture behavior of a commercial, high impact (HI), heat-cured denture base acrylic resin impregnated with different concentrations of yttria-stabilized zirconia (ZrO2) nanoparticles. Six groups were prepared having different wt% concentrations of ZrO2 nanoparticles: 0% (control), 1.5%, 3%, 5%, 7%, and 10%, respectively. Flexural strength and flexural modulus were measured using a three-point bending test and surface hardness was evaluated using the Vickers hardness test. Fracture toughness and impact strength were evaluated using a single edge bending test and Charpy impact instrument. The fractured surfaces of impact test specimens were also observed using a scanning electron microscope (SEM). Statistical analyses were conducted on the data obtained from the experiments. The mean flexural strength of ZrO2/PMMA nanocomposites (84 ± 6 MPa) at 3 wt% zirconia was significantly greater than that of the control group (72 ± 9 MPa) (p < 0.05). The mean flexural modulus was also significantly improved with different concentrations of zirconia when compared to the control group, with 5 wt% zirconia demonstrating the largest (23%) improvement. The mean fracture toughness increased in the group containing 5 wt% zirconia compared to the control group, but it was not significant. However, the median impact strength for all groups containing zirconia generally decreased when compared to the control group. Vickers hardness (HV) values significantly increased with an increase in ZrO2 content, with the highest values obtained at 10 wt%, at 0 day (22.9 HV0.05) in dry conditions when compared to the values obtained after immersing the specimens for seven days (18.4 HV0.05) and 45 days (16.3 HV0.05) in distilled water. Incorporation of ZrO2 nanoparticles into high impact PMMA resin significantly improved flexural strength, flexural modulus, fracture toughness and surface hardness, with an optimum concentration of 3–5 wt% zirconia. However, the impact strength of the nanocomposites decreased, apart from the 5 wt% zirconia group.

19 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
AAAbdulaziz Alhotan
Abdulaziz Alhotan
JYJulian Yates
Julian Yates
SZSaleh Zidan
Saleh Zidan
Julfikar HaiderJulfikar Haider
Julfikar Haider
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
The aim of this work was to evaluate the flexural strength and surface hardness of heat-cured Polymethyl methacrylate (PMMA) modified by the addition of ZrO2 nanoparticles, TiO2 nanoparticles, and E-glass fibre at different wt.% concentrations. Specimens were fabricated and separated into four groups (n = 10) to measure both flexural strength and surface hardness. Group C was the control group. The specimens in the remaining three groups differed according to the ratio of filler to weight of PMMA resin (1.5%, 3%, 5%, and 7%). A three-point bending test was performed to determine the flexural strength, while the surface hardness was measured using the Vickers hardness. Scanning Electron Microscope (SEM) was employed to observe the fractured surface of the specimens. The flexural strength was significantly improved in the groups filled with 3 wt.% ZrO2 and 5 and 7 wt.% E-glass fibre in comparison to Group C. All the groups displayed a significantly higher surface hardness than Group C, with the exception of the 1.5% TiO2 and 1.5% ZrO2 groups. The optimal filler concentrations to enhance the flexural strength of PMMA resin were between 3–5% ZrO2, 1.5% TiO2, and 3–7% E-glass fibre. Furthermore, for all composites, a filler concentration of 3 wt.% and above would significantly improve hardness.

30 May 2023 in Polymers
Verified
Journal Article
Open access
PDF file
AAAbdullah Alshamrani
Abdullah Alshamrani
AAAbdulaziz Alhotan
Abdulaziz Alhotan
EKElizabeth Kelly
Elizabeth Kelly
AEAyman Ellakwa
Ayman Ellakwa
This study aimed to assess the mechanical and biocompatibility properties of dental resin reinforced with different nanoparticle additives. Temporary crown specimens were 3D-printed and grouped based on nanoparticle type and amount, including zirconia and glass silica. Flexural strength testing evaluated the material’s ability to withstand mechanical stress using a three-point bending test. Biocompatibility was tested using MTT and dead/live cell assays to assess effects on cell viability and tissue integration. Fractured specimens were analysed using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) for fracture surface examination and elemental composition determination. Results show that adding 5% glass fillers and 10–20% zirconia nanoparticles significantly improves the flexural strength and biocompatibility of the resin material. Specifically, the addition of 10%, 20% zirconia, and 5% glass silica by weight significantly increases the flexural strength of the 3D-printed resins. Biocompatibility testing reveals cell viabilities greater than 80% in all tested groups. Reinforced 3D-printed resin holds clinical potential for restorative dentistry, as zirconia and glass fillers have been shown to enhance mechanical and biocompatibility properties of dental resin, making it a promising option for dental restorations. The findings of this study may contribute to the development of more effective and durable dental materials.

25 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
IAIslam Atta
Islam Atta
CBChristoph P Bourauel
Christoph P Bourauel
YAYasmine Alkabani
Yasmine Alkabani
NMNesreen Mohamed
Nesreen Mohamed
Hoon KimHoon Kim
Hoon Kim
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
To conduct a physiochemical and mechanical material analysis on 3D printed shape-memory aligners in comparison to thermoformed aligners. Four materials were examined, including three thermoformed materials: CA Pro (CP), Zendura A (ZA), Zendura FLX (ZF), and one 3D printed material: Tera Harz (TC-85). Rectangular strips measuring 50 × 10 × 0.5 mm were produced from each material. Five tests were conducted, including differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), shape recovery tests, three-points bending (3 PB), and Vickers surface microhardness (VH). DSC recorded glass transition temperatures (Tg) at 79.9 °C for CP, 92.2 °C for ZA, 107.1 °C for ZF, and 42.3 °C for TC-85. In DMA analysis at 20-45 °C, a prominent decrease in storage modulus was observed, exclusively for TC-85, as the temperature increased. Notably, within the temperature range of 30-45 °C, TC-85 exhibited substantial shape recovery after 10 min, reaching up to 86.1 %, while thermoformed materials showed minimal recovery (1.5-2.9 %). In 3 PB test (at 30, 37, 45 °C), ZA demonstrated the highest force at 2 mm bending, while TC-85 exhibited the lowest. Regarding VH at room temperature, there was a significant decrease for both ZA and ZF after thermoforming. ZA had the highest hardness, followed by ZF and TC-85, with CP showing the lowest values. TC-85 demonstrates exceptional shape memory at oral temperature, improving adaptation, reducing force decay, and enabling, together with its higher flexibility, extensive tooth movement per step. Additionally, it maintains microhardness similar to thermoformed sheets, ensuring the durability and effectiveness of dental aligners. The 3D printed aligner material with shape memory characteristics (4D aligner) has revolutionized the orthodontic aligner field. It showed mechanical properties more suitable for orthodontic treatment than thermoforming materials. Additionally, it offers enhanced control over aligner design and thickness, while optimizing the overall workflow. It also minimizes material wastage, and reduces production expenses.

24 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
AAAbdulaziz Alhotan
Abdulaziz Alhotan
JYJulian Yates
Julian Yates
SZSaleh Zidan
Saleh Zidan
Julfikar HaiderJulfikar Haider
Julfikar Haider
Nikolaos SilikasNikolaos Silikas
Nikolaos Silikas
Statement of Problem: Polymethyl methacrylate (PMMA) denture resins commonly fracture as a result of the denture being dropped or when in use due to heavy occlusal forces. Purpose: To investigate the effects of E-glass fibre, ZrO2 and TiO2 nanoparticles at different concentrations on the fracture toughness and impact strength of PMMA denture base. Materials and Methods: To evaluate fracture toughness (dimensions: 40 × 8 × 4 mm3; n = 10/group) and impact strength (dimensions: 80 × 10 × 4 mm3; n = 12/group), 286 rectangular tested specimens were prepared and divided into four groups. Group C consisted of the PMMA specimens without any filler (control group), while the specimens in the remaining three groups varied according to the concentration of three filler materials by weight of PMMA resin: 1.5%, 3%, 5%, and 7%. Three-point bending and Charpy impact tests were conducted to measure the fracture toughness and impact strength respectively. Scanning Electron Microscope (SEM) was utilised to examine the fractured surfaces of the specimens after the fracture toughness test. One-way analysis of variance (ANOVA) followed by Tukey post-hoc tests were employed to analyse the results at a p ≤ 0.05 significance level. Results: Fracture toughness of groups with 1.5 and 3 wt.% ZrO2, 1.5 wt.% TiO2, and all E-glass fibre concentrations were significantly higher (p < 0.05) than the control group. The samples reinforced with 3 wt.% ZrO2 exhibited the highest fracture toughness. Those reinforced with a 3 wt.%, 5 wt.%, and 7 wt.% of E-glass fibres had a significantly (p < 0.05) higher impact strength than the specimens in the control group. The heat-cured PMMA modified with either ZrO2 or TiO2 nanoparticles did not exhibit a statistically significant difference in impact strength (p > 0.05) in comparison to the control group. Conclusions: 1.5 wt.%, 3 wt.% of ZrO2; 1.5 wt.% ratios of TiO2; and 1.5 wt.%, 3 wt.%, 5 wt.%, and 7 wt.% of E-glass fibre can effectively enhance the fracture toughness of PMMA. The inclusion of E-glass fibres does significantly improve impact strength, while ZrO2 or TiO2 nanoparticles did not.

27 July 2024 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
Adolfo Di FioreAdolfo Di Fiore
Adolfo Di Fiore
ESEdoardo Stellini
Edoardo Stellini
OAOmar Alageel
Omar Alageel
AAAbdulaziz Alhotan
Abdulaziz Alhotan