Seungwon Kim

Dr. Seungwon Kim

Kangwon National University

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSeungwon Kim
Seungwon Kim
TJTaejin Jang
Taejin Jang
TOTopendra Oli
Topendra Oli
CPCheolwoo Park
Cheolwoo Park
Hydrogen gas storage place has been increasing daily because of its consumption. Hydrogen gas is a dream fuel of the future with many social, economic and environmental benefits to its credit. However, many hydrogen storage tanks exploded accidentally and significantly lost the economy, infrastructure, and living beings. In this study, a protection wall under a worst-case scenario explosion of a hydrogen gas tank was analyzed with commercial software LS-DYNA. TNT equivalent method was used to calculate the weight of TNT for Hydrogen. Reinforced concrete and composite protection wall under TNT explosion was analyzed with a different distance of TNT. The initial dimension of the reinforced concrete protection wall was taken from the Korea gas safety code book (KGS FP217) and studied the various condition. H-beam was used to make the composite protection wall. Arbitrary-Lagrangian-Eulerian (ALE) simulation from LS-DYNA and ConWep pressure had a good agreement. Used of the composite structure had a minimum displacement than a normal reinforced concrete protection wall. During the worst-case scenario explosion of a hydrogen gas 300 kg storage tank, the minimum distance between the hydrogen gas tank storage and protection wall should be 3.6 m.

10 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
AFAbidemi Bashiru Folorunsho
Abidemi Bashiru Folorunsho
SKSeungwon Kim
Seungwon Kim
CPCheolwoo Park
Cheolwoo Park
Multiple studies have investigated the use of steel, synthetic fibers, and natural fibers to reduce plastic shrinkage cracks in concrete, which are mostly caused by water evaporation from the surface of the material. This review used original published research articles from the Web of Science and Scopus database to evaluate the performance and relationship between the fiber volume, aspect ratio, compressive strength, and plastic shrinkage cracking. This review also discussed the most widely used technique for evaluating plastic shrinkage cracking, the ASTM C 1579, with two bottom restraints and a central stress riser to induce cracking, and its modified version with additional reinforcement for further restraining the ASTM C 1579 mold. Longer fibers function better than shorter fibers because of their larger surface area, which allows them to bridge fissures. It was also observed that crack initiation time is delayed when fibers are added to concrete. In addition, as the volume proportion of the fibers increased, the plastic shrinkage cracks decreased, but the compressive strength declined. Furthermore, the volume fraction of the fibers had a greater effect on reducing cracking than the aspect ratio. It was also concluded that a fiber volume inclusion below 1% is best.

6 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSeungwon Kim
Seungwon Kim
JSJaewon Shim
Jaewon Shim
Ji-Young RheeJi-Young Rhee
Ji-Young Rhee
DJDaegyun Jung
Daegyun Jung
CPCheolwoo Park
Cheolwoo Park
Fire in a tunnel or an underground structure is characterized by a rise in temperature above 1000 °C in 5–10 min, which is due to the characteristics of the closed space. The Permanent International Association of Road Congresses has reported that serious damage can occur in an underground structure as a consequence of high temperatures of up to 1400 °C when a fire accident involving a tank lorry occurs in an underground space. In these circumstances, it is difficult to approach the scene and extinguish the fire, and the result is often casualties and damage to facilities. When a concrete structure is exposed to a high temperature, spalling or dehydration occurs. As a result, the cross section of the structure is lost, and the structural stability declines to a great extent. Furthermore, the mechanical and thermal properties of concrete are degraded by the temperature hysteresis that occurs at high temperatures. Consequently, interest in the fire safety of underground structures, including tunnels, has steadily increased. This study conducted a fire simulation to analyze the effects of a fire caused by dangerous-goods vehicles on the tunnel structure. In addition, a fire exposure test of reinforced-concrete members was conducted using the Richtlinien für die Ausstattung und den Betrieb von Straßentunneln (RABT) fire curve, which is used to simulate a tunnel fire.

13 October 2019 in Materials
Verified
Journal Article
Open access
PDF file
SKSeungwon Kim
Seungwon Kim
DKDong Joo Kim
Dong Joo Kim
SKSung-Wook Kim
Sung-Wook Kim
CPCheolwoo Park
Cheolwoo Park
Concrete has high compressive strength, but low tensile strength, bending strength, toughness, low resistance to cracking, and brittle fracture characteristics. To overcome these problems, fiber-reinforced concrete, in which the strength of concrete is improved by inserting fibers, is being used. Recently, high-performance fiber-reinforced cementitious composites (HPFRCCs) have been extensively researched. The disadvantages of conventional concrete such as low tensile stress, strain capacity, and energy absorption capacity, have been overcome using HPFRCCs, but they have a weakness in that the fiber reinforcement has only 2% fiber volume fraction. In this study, slurry infiltrated fiber reinforced cementitious composites (SIFRCCs), which can maximize the fiber volume fraction (up to 8%), was developed, and an experimental study on the tensile behavior of SIFRCCs with varying fiber volume fractions (4%, 5%, and 6%) was carried out through direct tensile tests. The results showed that the specimen with high fiber volume fraction exhibited high direct tensile strength and improved brittleness. As per the results, the direct tensile strength is approximately 15.5 MPa, and the energy absorption capacity was excellent. Furthermore, the bridging effect of steel fibers induced strain hardening behavior and multiple cracks, which increased the direct tensile strength and energy absorption capacity.

18 May 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HJHaekook Jung
Haekook Jung
TOTopendra Oli
Topendra Oli
JNJeonghee Nam
Jeonghee Nam
KYKyong-Ku Yun
Kyong-Ku Yun
SKSeungwon Kim
Seungwon Kim
CPCheolwoo Park
Cheolwoo Park
Concrete pavement proportions are increasing in Korean expressways, resulting in increased maintenance cost. The length of degenerate concrete pavements that have exceeded the design life (20 years) was 1150 km in 2015 and 2605 km in 2020 and is expected to rapidly increase. To extend the service life of concrete pavements, life-cycle cost (LCC) analysis was conducted on asphalt and concrete overlays, based on the different maintenance methods. LCC analysis was performed when the shoulder was used and when it was not used between 6000 and 35,000 AADT traffic according to the two-lane and four-lane traffic. During overlay, one lane was completely blocked, and the value per vehicle was converted into the user cost using the Construction Analysis for Pavement Rehabilitation Strategies software, according to whether the shoulder was used to maintain the number of lanes. In addition, LCC analysis was conducted by examining the construction cost and life-cycle according to each overlay method. When the shoulder was used, the total construction cost decreased, owing to the reduction in user cost, indicating that the implementation of the traffic measure of using the road shoulder improves user satisfaction and cost. The asphalt overlay was observed to be more favorable than concrete overlay in terms of the initial total construction cost. However, under a 20-year cycle, the economic efficiency of concrete overlay was higher than that of asphalt overlay. After repairing the deteriorated target sections of concrete pavements, the overlay method (asphalt or concrete) ought to be selected according to the target service life for beneficial economic effect. Concrete overlay was to obtain about 20% or greater LCC effect compared to asphalt overlay, and at least 5% or more additional LCC effect obtained when the shoulder was used.

1 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
SKSeungwon Kim
Seungwon Kim
SHSeungyeon Han
Seungyeon Han
CPCheolwoo Park
Cheolwoo Park
KYKyong-Ku Yun
Kyong-Ku Yun
The compressive stress of concrete is used as a design variable for reinforced concrete structures in design standards. However, as the performance-based design is being used with increasing varieties and strengths of concrete and reinforcement bars, mechanical properties other than the compressive stress of concrete are sometimes used as major design variables. In particular, the evaluation of the mechanical properties of concrete is crucial when using fiber-reinforced concrete. Studies of high volume fractions in established compressive behavior prediction equations are insufficient compared to studies of conventional fiber-reinforced concrete. Furthermore, existing prediction equations for the mechanical properties of high-performance fiber-reinforced cementitious composite and high-strength concrete have limitations in terms of the strength and characteristics of contained fibers (diameter, length, volume fraction) even though the stress-strain relationship is determined by these factors. Therefore, this study developed a high-performance slurry-infiltrated fiber-reinforced cementitious composite that could prevent the fiber ball phenomenon, a disadvantage of conventional fiber-reinforced concrete, and maximize the fiber volume fraction. Then, the behavior characteristics under compressive stress were analyzed for fiber volume fractions of 4%, 5%, and 6%.