Tuty Emilia Agustina

Prof. Dr. Tuty Emilia Agustina

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2005 in Journal of Photochemistry and Photobiology C: Photochemistry Reviews
Verified
Journal Article
Closed access
TATuty Emilia Agustina
Tuty Emilia Agustina
HAH.M. Ang
H.M. Ang
VVV.K. Vareek
V.K. Vareek

1 January 2008 in Chemical Engineering Journal
Verified
Journal Article
Closed access
TATuty Emilia Agustina
Tuty Emilia Agustina
HAH.M. Ang
H.M. Ang
VPV.K. Pareek
V.K. Pareek

1 February 2021 in Journal of Ecological Engineering
Verified
Journal Article
Open access
RGRianyza Gayatri
Rianyza Gayatri
TATuty Emilia Agustina
Tuty Emilia Agustina
RMRosdiana Moeksin
Rosdiana Moeksin
DBDavid Bahrin
David Bahrin
GGGustini Gustini
Gustini Gustini
The increasing growth of the textile industry does not only provide benefits in the economic sector but also has the potential to damage the environment, because it generates the dye wastewater which is hard to eliminate. Procion red is one of the synthetic textile dyes that is toxic to the...

10 February 2019 in Indonesia Journal of Fundamental and Applied Chemistry
Verified
Journal Article
Open access
PDF file
EAEndi Adriansyah
Endi Adriansyah
TATuty Emilia Agustina
Tuty Emilia Agustina
SASusila Arita
Susila Arita
Leachate Treatment of TPA Talang Gulo, Jambi City by Fenton method and adsorption

19 January 2022 in Jurnal Ilmu Lingkungan
Verified
Journal Article
Open access
PDF file
NANovi Anggraini
Novi Anggraini
TATuty Emilia Agustina
Tuty Emilia Agustina
FHFitri Hadiah
Fitri Hadiah
Air limbah laboratorium seharusnya tidak dibuang langsung ke lingkungan tanpa pengolahan lebih lanjut. Hal ini dapat menimbulkan pencemaran terhadap lingkungan yang dampaknya juga dirasakan oleh makhluk hidup di sekitarnya. Bahan yang terkandung dalam air limbah laboratorium tergolong limbah bahan berbahaya dan beracun (B3) yang mengandung bahan organik dan anorganik seperti Cd, Pb, Cu, Hg, Cr, Zn, Fe, dan logam berat lainnya. Penelitian ini bertujuan untuk mereduksi logam berat dalam air limbah laboratorium dengan metode adsorpsi menggunakan adsorben. Oleh karena itu, penelitian ini difokuskan pada penurunan kadar logam berat Pb, Cu, dan Cd pada air limbah laboratorium dengan karbong aktif dan zeolit sintetik sebagai adsorben. Persentase penyisihan logam Pb terbesar dengan menggunakan karbon aktif sebesar 97,93% dicapai pada pH 7, sedangkan dengan menggunakan zeolit sintetik sebesar 98,47% yang dicapai pada pH 6. Persentase terbesar penyisihan logam Cu menggunakan karbon aktif mencapai 98,33% diperoleh pada pH 9, sedangkan persentase terbesar penyisihan logam Cu dengan adsorben zeolit sintetis mencapai 99,87% diperoleh pada pH 4. Persentase penyisihan logam Cd tertinggi dengan karbon aktif mencapai 98,60% dan dengan zeolit sintetik sebesar 97,20%, yang dicapai pada pH sama yaitu pada pH 8. Dapat disimpulkan bahwa nilai pH berpengaruh pada penurunan logam Pb dan Cu dengan metode adsorpsi menggunakan karbon aktif dan zeolit sintetik, sedangkan untuk logam Cd, pengaruh pH tidak signifikan. Laboratory wastewater should not discharge directly into the environment without further processing. This can cause pollution to the environment whose impact is also felt by living things around it. The materials contained in laboratory wastewater are classified as hazardous and toxic waste (B3) containing organic and inorganic materials such as Cd, Pb, Cu, Hg, Cr, Zn, Fe, and other heavy metals. This study aims to reduce heavy metals in laboratory wastewater using the adsorption method of adsorbents. Therefore, this study focused on reducing the levels of heavy metals Pb, Cu, and Cd in laboratory wastewater using the activated carbon and synthetic zeolite as adsorbents. The largest percentage of Pb metal removal using activated carbon of 97.93% was achieved at pH 7, while by using synthetic zeolite was 98.47% achieved at pH 6. The largest percentage of Cu metal removal using activated carbon adsorbent of 98.33% was obtained at pH 9, while the largest percentage of Cu metal removal with synthetic zeolite of 99.87% was reached at pH 4. The highest percentage of Cd metal removal with activated carbon of 98.60 % and with synthetic zeolite of 97.20%, which were achieved at the same pH of 8. It can be concluded that the pH value influences the reduction of Pb and Cu metals by adsorption method using activated carbon and synthetic zeolite, as for Cd metal, the effect of pH is not significant.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Open access
MSMelati Ireng Sari
Melati Ireng Sari
TATuty Emilia Agustina
Tuty Emilia Agustina
EMElda Melwita
Elda Melwita
TATine Aprianti
Tine Aprianti
Increasing textile industries in Indonesia resulted in increasing the utilization of dyes. The use of synthetic dyes are still dominating because they have many advantages. But, synthetic dyes are difficult to decompose in nature so they can cause potential pollution if discharged directly into the environment. In this study, Procion Red was used as a model of synthetic dye wastewater. The objective of this research is to study the effect of TiO2 catalyst concentration and irradiation time on the degradation of Procion Red under solar irradiation. Photo degradation takes place by using TiO2 catalyst powder in the various concentration of Procion Red of 150-300 ppm. The various concentrations of TiO2 catalyst of 0.5-8 g/l were used. The color and COD degradation of Procion Red for 12 hours of solar irradiation were investigated. Color degradation was measured by using a spectrophotometer. While COD degradation was measured by using Ferrous Ammonium Sulfate (FAS) analysis method. The result showed when using Procion Red of 150 ppm, the highest color degradation of 100% was achieved by using TiO2 catalyst of 6 g/l and the highest COD degradation of 62% was obtained by using TiO2 catalyst of 8 g/l, under 12 hours of solar irradiation