Jingjie Yang

Dr. Jingjie Yang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2024 in Thin-Walled Structures
Verified
Journal Article
Closed access
KLKai Luo
Kai Luo
HLHaifeng Li
Haifeng Li
JYJingjie Yang
Jingjie Yang
HKHaixin Kang
Haixin Kang
FYFengzuo Yan
Fengzuo Yan
XHXue Han
Xue Han


27 December 2024 in Thin-Walled Structures
Verified
Journal Article
Closed access
KLKai Luo
Kai Luo
HLHaifeng Li
Haifeng Li
JYJingjie Yang
Jingjie Yang
SFSibao Fang
Sibao Fang
FYFengzuo Yan
Fengzuo Yan
XNXizhan Ning
Xizhan Ning

19 December 2024 in International Journal of Structural Stability and Dynamics
Verified
Journal Article
Closed access
LWLizhen Wei
Lizhen Wei
KLKai Luo
Kai Luo
JYJingjie Yang
Jingjie Yang
HLHaifeng LI
Haifeng LI
XNXizhan Ning
Xizhan Ning
Yu-ye XuYu-ye Xu
Yu-ye Xu

21 April 2025 in Engineering Structures
Verified
Journal Article
Closed access
JYJingjie Yang
Jingjie Yang
SFSibao Fang
Sibao Fang
HLHaifeng Li
Haifeng Li
WWWeiyong Wang
Weiyong Wang
XHXue Han
Xue Han

21 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Weihua WangWeihua Wang
Weihua Wang
涛朱涛 朱
涛 朱
XGXian Gao
Xian Gao
JYJingjie Yang
Jingjie Yang
XCXilong Chen
Xilong Chen
WWWeiyong Wang
Weiyong Wang
Fire safety design for steel beams is crucial in the construction of steel structures. However, there remains a significant gap in the testing of the fire resistance of insulated steel beams. This study focuses on full-scale experimental research examining the fire resistance performance of steel beams with varying fire protection methods, cross-sectional dimensions, and heating curves. During the tests, the furnace temperature, specimen temperature, and deflection at mid-span were measured. The test results indicated that specimens mainly failed in lateral-torsional buckling. Additionally, a markedly non-uniform temperature distribution was observed across the cross-section, and the predictions made by GB 51249-2017 were found to be unsafe. The use of fiber cement board for fire protection may be ineffective, as it tends to become brittle at elevated temperatures, making it susceptible to breakage and detachment when the beams begin to bend. Furthermore, due to potential creep deformation, specimens subjected to longer heating durations exhibited lower critical temperatures compared to those with shorter heating durations. Finally, the design method outlined in BS EN 1993-1-2 and ANSI/AISC 360-22 was evaluated against the test results, indicating an accurate prediction of these methods for specimens with shorter heating durations, but an unconservative prediction for specimens with longer heating durations due to ignorance of creep deformation.