Weihua Wang

Dr. Weihua Wang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

18 June 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Weihua WangWeihua Wang
Weihua Wang
TZTao Zhu
Tao Zhu
XGXian Gao
Xian Gao
JYJingjie Yang
Jingjie Yang
XCXilong Chen
Xilong Chen
WWWeiyong Wang
Weiyong Wang
Fire safety design for steel beams is crucial in the construction of steel structures. However, there remains a significant gap in the fire resistance testing of insulated steel beams. This study focuses on full-scale experimental research examining the fire resistance performance of steel beams with varying fire protection methods, cross-sectional dimensions, and heating curves. During the tests, the furnace temperature, specimen temperature, and deflection at mid-span were measured. The test results indicated that specimens mainly failed in lateral–torsional buckling. Additionally, a markedly non-uniform temperature distribution was observed across the cross-section, and the predictions made by GB 51249-2017 were found to be unsafe. The use of fiber cement board for fire protection may be ineffective, as it tends to become brittle at elevated temperatures, making it susceptible to breakage and detachment when the beams begin to bend. Furthermore, due to potential creep deformation, specimens subjected to longer heating durations exhibited lower critical temperatures compared to those with shorter heating durations. Finally, the design method outlined in BS EN 1993-1-2 and ANSI/AISC 360-22 was evaluated against the test results, indicating an accurate prediction of these methods for specimens with shorter heating durations, but an unconservative prediction for specimens with longer heating durations due to ignorance of creep deformation.

16 May 2020 in Fracture and Structural Integrity
Verified
Journal Article
Open access
PDF file
DWDongye Wang
Dongye Wang
YDYuli Dong
Yuli Dong
Dashan ZhangDashan Zhang
Dashan Zhang
Weihua WangWeihua Wang
Weihua Wang
XLXin Lu
Xin Lu
This paper attempts to disclose the damage mechanism of reinforced concrete plate-column structure under room temperature and fire. Several tests were carried out to record the law of crack development on the plate surface under room temperature. The infrared detection technology was adopted to observe how cracks develop under fire. The acoustic emission (AE) signals at different positions of the specimen were monitored by the AE techniques. Coupled with the macroscopic test phenomena, several characteristic parameters collected by the AE system, namely, cumulative number of events, event rate, energy rate and b-value, were analyzed in details. The results show that: the cumulative number of events was active in the loading, heating and cooling stages; the crack density and the change of internal forces could be derived from the trend of event rate; the local energy changes of the specimen could be deciphered from the curves of energy rate and b-value, making it possible to judge if a component has reached the failure state; the specimen suffered the most severe damages, when the AE parameters suddenly changed; AE monitoring enables the early warning of fire to reinforced concrete plate-column structure; infrared detection technology is suitable for real-time monitoring of crack development under high temperature.

21 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Weihua WangWeihua Wang
Weihua Wang
涛朱涛 朱
涛 朱
XGXian Gao
Xian Gao
JYJingjie Yang
Jingjie Yang
XCXilong Chen
Xilong Chen
WWWeiyong Wang
Weiyong Wang
Fire safety design for steel beams is crucial in the construction of steel structures. However, there remains a significant gap in the testing of the fire resistance of insulated steel beams. This study focuses on full-scale experimental research examining the fire resistance performance of steel beams with varying fire protection methods, cross-sectional dimensions, and heating curves. During the tests, the furnace temperature, specimen temperature, and deflection at mid-span were measured. The test results indicated that specimens mainly failed in lateral-torsional buckling. Additionally, a markedly non-uniform temperature distribution was observed across the cross-section, and the predictions made by GB 51249-2017 were found to be unsafe. The use of fiber cement board for fire protection may be ineffective, as it tends to become brittle at elevated temperatures, making it susceptible to breakage and detachment when the beams begin to bend. Furthermore, due to potential creep deformation, specimens subjected to longer heating durations exhibited lower critical temperatures compared to those with shorter heating durations. Finally, the design method outlined in BS EN 1993-1-2 and ANSI/AISC 360-22 was evaluated against the test results, indicating an accurate prediction of these methods for specimens with shorter heating durations, but an unconservative prediction for specimens with longer heating durations due to ignorance of creep deformation.