Maria Costanza Soldini

Dr. Maria Costanza Soldini

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2025 in Clinical Oral Implants Research
Verified
Journal Article
Open access
AMAlberto Monje
Alberto Monje
RPRamon Pons
Ramon Pons
MSMaria Costanza Soldini
Maria Costanza Soldini
PRPaul S. Rosen
Paul S. Rosen
JNJosé Nart
José Nart
DBDaniel Buser
Daniel Buser
Objective: A cross‐sectional study was made to evaluate the role of local factors, including surgical, implant, and prosthesis‐related parameters, in the presence of peri‐implantitis. Methods: Consecutive partially edentulous patients with ≥ 1 implant presenting peri‐implantitis were included. Clinical and radiographic data were collected to characterize local factors. Overall, 28 site‐specific variables were analyzed for peri‐implantitis and non‐peri‐implantitis implants. Simple and multiple logistic regression analyses were performed to explore potential associations. The diagnostic accuracy of those variables that demonstrated statistical significance in the multiple logistic regression analysis was further tested. Results: In total, 100 patients with 452 implants met the inclusion criteria. Of these, 227 implants (50.2%) were diagnosed with peri‐implantitis, while 225 (49.8%) did not present peri‐implantitis. The multiple logistic regression analysis demonstrated statistical significance for the following factors: (1) medial implant position within the prosthesis (OR = 3.9) was more prone to develop peri‐implantitis; (2) internal Morse taper implant connection was the least likely to develop peri‐implantitis (OR = 0.43); (3) mesio‐distally centered implants were less prone to exhibit peri‐implantitis (OR = 0.46); (4) bucco‐lingual centered implants were less prone to exhibit peri‐implantitis (OR = 0.29); (5) implants positioned inside (≥ 2 mm) the bony housing were less prone to exhibit peri‐implantitis (OR = 0.13); and (6) implants tilted 10°–30° (OR = 5.84) and ≥ 30° (OR = 7.43) were more prone to exhibit peri‐implantitis. Moreover, a prediction model based on the aforementioned factors yielded a high level of accuracy. Conclusions: Implant malpositioning is a critical factor associated with peri‐implantitis.

22 July 2025 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
AMAlberto Monje
Alberto Monje
SNSofía Navarro‐Mesa
Sofía Navarro‐Mesa
MSMaria Costanza Soldini
Maria Costanza Soldini
GZGiorgio Zappalá
Giorgio Zappalá
PPPedro Peña
Pedro Peña
RPRamón Pons
Ramón Pons
Objective: To compare the clinical/radiographic outcomes and the rate of disease resolution of the adjunctive use of electrolysis (GS) or hydrogen peroxide (HP) for mechanical decontamination in the reconstructive treatment of peri‐implantitis‐related intrabony defects.Material and Methods: A multicenter randomized clinical trial was designed to compare the effectiveness and safety of two strategies for the surface decontamination of crater‐like and circumferential intrabony defects subjected to reconstructive therapy. Clinical evaluation was made at baseline (T0), 6 months (T1) and 12 months (T2), while radiographic assessment was carried out at T0 and T2. Disease resolution was the primary outcome. Supportive therapy was administered following surgical treatment. Simple and multiple generalized estimating equations (GEE) models were applied to compare the outcomes achieved and to explore potential confounders. Post hoc power calculation was performed to validate the statistical power of the findings.Results: Overall, 58 patients completed the study. All the clinical parameters/indices, namely probing pocket depth, modified sulcular bleeding index, suppuration grading index, and width of keratinized mucosa, showed a significant reduction (p < 0.001) from T0 to T2 in both tested groups. Mucosal recession increased (p < 0.001) from T0 to T2. Marginal bone level and radiographic defect angle increased (p < 0.001) from T0 to T2. The disease resolution rate was 87.5% for the GS group and 64.5% for the HP group at T2 (p = 0.08). No major postoperative complications were reported.Conclusion: Both tested surface decontamination methods are effective in resolving peri‐implantitis, in gaining radiographic marginal bone levels, and in enhancing clinical peri‐implant conditions in the surgical reconstructive therapy (NCT05615051).

4 August 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
Felice LorussoFelice Lorusso
Felice Lorusso
Antonio ScaranoAntonio Scarano
Antonio Scarano
Rexhep Sergio TariRexhep Sergio Tari
Rexhep Sergio Tari
ISIshita Singhal
Ishita Singhal
Funda GokerFunda Goker
Funda Goker
Massimo Del FabbroMassimo Del Fabbro
Massimo Del Fabbro
Background: The implant–abutment joint is important for the long-term marginal tissue integrity in terms of biomimetic design that replicates the natural dentition under mastication forces. This study aimed to evaluate conical implant–abutment joints coupled at different tightening torque values through a mechanical fatigue test. Methods: Eighty conic implants (Ø: 3.8 mm L: 10 mm) with a 6° cone morse joint were embedded in resin blocks with an inclination of 30° ± 2°. The samples were divided into 8 groups (4 Test and 4 Control). The implant–abutment joints were coupled with different tightening torques: 25 Ncm (Group I), 30 Ncm (Group II), 35 Ncm (Group III) and 40 Ncm (Group IV). An in vitro cyclic loading test (1 × 104 loads) was performed for 4 Test groups, while 4 Control groups did not receive any forces. All the samples were assessed with Scanning Electron Microscopy to compare the microfractures and microgaps on flexion and extension points. Results: Microscopy observation results showed significant differences among torque groups. We found that 30 Ncm had the best stability with less microgap. Conclusions: Tightening torque plays an important role in the distortion of the cone morse joint under mechanical forces. However, further studies should be conducted to validate the results using different implant–abutment joints for comparison.

9 April 2026 in Periodontology 2000
Verified
Journal Article
Open access
Hom-Lay WangHom-Lay Wang
Hom-Lay Wang
JCJavier Calatrava
Javier Calatrava
MSMaria Costanza Soldini
Maria Costanza Soldini
JVJavi Vilarrasa
Javi Vilarrasa
ASAnton Sculean
Anton Sculean
AMAlberto Monje
Alberto Monje
Background: Supportive periodontal and peri‐implant maintenance therapy is strongly associated with improved long‐term retention and stability of natural teeth and dental implants. Lack of regular professional follow‐up after initial therapy is a major risk factor for disease recurrence and tooth or implant loss. Despite well‐established benefits, patient compliance with maintenance regimens remains suboptimal, and the ideal protocols and intervals for sustained tissue health are under debate, Aim: This review aimed to synthesize current evidence regarding the impact of supportive therapy on long‐term periodontal and peri‐implant tissue stability, including optimal maintenance intervals, protocols, risk profiles, and emerging technologies for personalized care. Material and Methods: A comprehensive literature review was conducted using PubMed, Embase, and Scopus databases, focusing on longitudinal and cohort studies, randomized controlled trials, systematic reviews, and recent consensus guidelines addressing the effects of supportive therapy on periodontal and peri‐implant outcomes. Data on maintenance intervals, clinical protocols, risk assessment tools, recurrence after nonsurgical and surgical therapies, and adjunctive innovations (AI, imaging, biomarker testing) were collated and critically appraised. Results: Long‐term studies consistently demonstrate that regular supportive periodontal care (SPC) and supportive peri‐implant care (SPIC) markedly reduce rates of tooth and implant loss, progression of periodontitis and peri‐implantitis, and minimize the need for complex surgical re‐interventions. Frequent recalls—every 3–6 months for moderate‐ to high‐risk patients and up to 12 months for low‐risk—result in significantly better outcomes. Protocols incorporating individualized risk assessment (e.g., Personalized Risk Assessment (PRA) and Implant Disease Risk Assessment (IDRA) algorithms), thorough mechanical biofilm removal, personalized oral hygiene instructions, and modification of risk factors enhance tissue stability. Non‐compliance and residual pockets (≥5–6 mm) are major predictors of recurrence. While both conventional and emerging biofilm control methods (ultrasonic scaling, air‐polishing, guided biofilm therapy) are effective, no single protocol shows superior long‐term results. Recent advances in chair‐side biomarker testing and AI‐supported image analysis offer promising tools for early detection and proactive management of at‐risk patients. Although early data are encouraging, the clinical integration of these technologies remains largely guided by expert interpretation pending long‐term outcome validation. Conclusions: Consistent adherence to structured supportive therapy protocols following active periodontal or implant interventions is essential for the long‐term health and stability of periodontal and peri‐implant tissues. Maintenance intervals and protocols should be individualized based on patient, site, and prosthetic risk profiles, with cumulative and interceptive strategies employed for disease prevention and early management of recurrence Clinical Relevance: The implementation of personalized supportive therapy regimens—including regular recalls, risk‐based protocol selection, and integration of emerging technologies—substantially enhances the longevity and stability of teeth and implants. Improving patient and clinician awareness, and adopting risk‐stratified approaches, can reduce disease recurrence, treatment burden, and long‐term healthcare costs.

4 April 2025 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
MSMaria Costanza Soldini
Maria Costanza Soldini
RPRamón Pons
Ramón Pons
JNJosé Nart
José Nart
AMAlberto Monje
Alberto Monje
NCNeus Carrió
Neus Carrió
CVCristina Valles
Cristina Valles

1 January 2025 in Case Reports in Dentistry
Verified
Journal Article
Open access
YJYou Jiajia
You Jiajia
MSMaria Costanza Soldini
Maria Costanza Soldini
RPRamón Pons
Ramón Pons
CVCristina Valles
Cristina Valles
Background: Accurate placement of dental osseointegrated implants is critical for long‐term success, with factors significantly influencing stability and integration with surrounding tissues (i.e., depth, angle, and positioning within the bone). Nowadays, dental surgeries assisted by implant robots are gaining popularity. This occurs because dental robots provide precise and accurate minimally invasive surgery. Methods: A 46‐year‐old woman visited a private dental clinic with missing teeth in positions 4.5 and 4.6. Upon clinical and radiographic examination, severe ridge atrophy was observed. To address this, horizontal and vertical guided bone regeneration (GBR) was performed using a customized titanium occlusive membrane. After 6 months, DICOM files of the patients were imported into the robot implant planning software (RemebotDent, Remebot, Beijing Rui Yi Bo Technology DICOM Ltd., China) for the placement of two dental implants (CLC CONIC, CLC Scientific, Vicenza, Italy). Results: After the GBR procedure, vertical bone gain was on average 2 mm, whereas horizontal bone gain was 5.28 and 5.34 mm in the middle position of 4.5 and 4.6. The robot‐assisted surgery revealed high accuracy, since the implants in positions 4.5 and 4.6 showed a coronal global deviation of 0.42 and 0.57 mm and angular deviation of 0.62° and 0.69°, respectively. Conclusions: This robotic surgical system can offer high accuracy and reliability with the preoperative plan. The potential for future collaboration between robots and surgeons may significantly alter the landscape of implant dentistry, and further studies are needed to confirm the accuracy of robotic implant placement.