Leakage current minimization is one of the most important considerations in transformerless photovoltaic (PV) inverters. In the past, various transformerless PV inverter topologies have been introduced, with leakage current minimized by the means of galvanic isolation and common-mode voltage (CMV) clamping. The galvanic isolation can be achieved via dc-decoupling or ac-decoupling, for isolation on the dc- or ac-side of the inverter, respectively. It has been shown that the latter provides lower losses due to the reduced switch count in conduction path. Nevertheless, leakage current cannot be simply eliminated by galvanic isolation and modulation techniques, due to the presence of switches' junction capacitances and resonant circuit effects. Hence, CMV clamping is used in some topologies to completely eliminate the leakage current. In this paper, several recently proposed transformerless PV inverters with different galvanic isolation methods and CMV clamping technique are analyzed and compared. A simple modified H-bridge zero-voltage state rectifier is also proposed, to combine the benefits of the low-loss ac-decoupling method and the complete leakage current elimination of the CMV clamping method. The performances of different topologies, in terms of CMV, leakage current, total harmonic distortion, losses and efficiencies are compared. The analyses are done theoretically and via simulation studies, and further validated with experimental results. This paper is helpful for the researchers to choose the appropriate topology for transformerless PV applications and to provide the design principles in terms of common-mode behavior and efficiency.
2 June 2014 in IEEE Transactions on Industrial Electronics
Recently, reduced common-mode voltage (CMV) pulsewidth modulation (RCMV-PWM) methods have been proposed to reduce the leakage current in three-phase transformerless photovoltaic (PV) systems. However, most of these studies only focus on leakage current elimination and neglect the overall performance of the PV systems on issues such as cost, voltage linearity, dc-link current ripples, and harmonic distortion. In this paper, a three-phase transformerless inverter, adapted from the single-phase H5 topology, is investigated. Since the H5 topology has been conventionally developed for a single-phase system, its adaptation to the three-phase system requires the development of corresponding three-phase modulation techniques. Hence, modulation techniques are proposed based on conventional PWM. The performances of the proposed PWM, in terms of CMV, leakage current, voltage linearity, output current ripples, dc-link current ripples, and harmonic distortion are studied and discussed via simulation and experiment. It is proven that the proposed topology is able reduce the leakage current without sacrificing the overall performance of the system.
22 March 2017 in IEEE Transactions on Industrial Electronics
This paper underpins the principles for generating reactive power in single-phase transformerless photovoltaic (PV) inverters. Two mainstream and widely adopted PV inverters are explored, i.e., H5 and HERIC. With conventional modulation techniques, reactive power cannot be realized in H5 and HERIC due to the absence of freewheeling path in negative power region. Based on the study, modulation techniques are proposed to provide bidirectional current path during freewheeling period. With proposed modulation technique, reactive power control is achieved in H5 and HERIC inverters, without any modification on the converter structures. The performances of the proposed modulation techniques are studied via MATLAB simulation and further validated with experimental results.
Variable switching frequency pulse width modulation (VSF PWM) has been proposed in the past to optimize the total harmonic distortion (THD) performance and switching losses of an inverter. Nevertheless, such VSF PWMs give rise to switching harmonics which vary across a wide frequency spectrum, where the lower frequencies could resonate with the filter while the upper frequency could exceed the maximum switching frequency. This complicates VSF PWM design, restricting their practical uses. In this paper, a confined band VSF PWM (CB-VSF PWM) for a single-phase inverter with an LCL filter is presented. By confining the switching frequencies within a practical band, the design of the filter becomes easier while maintaining low current THD with low switching losses. The choices of the upper and lower bands of the proposed VSF are defined and the design criterion is introduced. It is found that the proposed method allows reduction in switching losses as well as reduction in current THD when the effect of the LCL filter is taken into consideration. The performance analysis is validated through simulation and experimental results in a 1 kW inverter.
Here, a highly efficient MOSFET neutral‐point‐clamped (M‐NPC) transformerless inverter is proposed for photovoltaic (PV) applications. By employing super‐junction metal–oxide–semiconductor field‐effect transistor (SJ‐MOSFET) as well as silicon carbide (SiC) diodes, high efficiency is achieved. Furthermore, the common‐mode voltage (CMV) is completely clamped at half of the input voltage with clamping branch. Therefore, leakage current is eliminated. The performances of different topologies, in terms of CMV, leakage current, total harmonic distortion (THD), losses, and efficiency, are compared with the proposed M‐NPC topology. The analyses are carried out theoretically via MATLAB/Simulink, and further validated with experimental tests. The experimental results show maximum efficiency of 98.5% and European efficiency of 97.65%.