Kornel Pietrzak

Dr. Kornel Pietrzak


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2018 in Materials
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
SGSofia Gaiaschi
Sofia Gaiaschi
patrick chaponpatrick chapon
patrick chapon
SRSteinar Raaen
Steinar Raaen
KPKornel Pietrzak
Kornel Pietrzak
In this paper, the characteristics of new porous coatings fabricated at three voltages in electrolytes based on H3PO4 with calcium nitrate tetrahydrate, magnesium nitrate hexahydrate, and copper(II) nitrate trihydrate are presented. The SEM, energy dispersive spectroscopy (EDS), glow discharge optical emission spectroscopy (GDOES), X-ray photoelectron spectroscopy (XPS), and XRD techniques for coating identification were used. It was found that the higher the plasma electrolytic oxidation (PEO) (micro arc oxidation (MAO)) voltage, the thicker the porous coating with higher amounts of built-in elements coming from the electrolyte and more amorphous phase with signals from crystalline Ca(H2PO4)2∙H2O and/or Ti(HPO4)2∙H2O. Additionally, the external parts of the obtained porous coatings formed on titanium consisted mainly of Ti4+, Ca2+, Mg2+ and PO43−, HPO42−, H2PO4−, P2O74− as well as Zn2+ or copper Cu+/Cu2+. The surface should be characterized by high biocompatibility, due to the presence of structures based on calcium and phosphates, and have bactericidal properties, due to the presence of zinc and copper ions. Furthermore, the addition of magnesium ions should accelerate the healing of postoperative wounds, which could lead to faster patient recovery.

6 February 2018 in Metals
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
SGSofia Gaiaschi
Sofia Gaiaschi
patrick chaponpatrick chapon
patrick chapon
SRSteinar Raaen
Steinar Raaen
Joao FernandesJoao Fernandes
Joao Fernandes
The aim of the paper is to study and determine the effect of voltage increasing from 500 up to 650 VDC on chemical and electrochemical properties of the obtained porous coatings with plasma electrolytic oxidation (PEO) processes, known also as micro arc oxidation (MAO). In the present paper, the chemical and electrochemical characterization of porous phosphate coatings enriched with magnesium or zinc on commercially pure (CP) Titanium Grade 2 under DC-PEO obtained in electrolytes based on concentrated 85% analytically pure H3PO4 (98 g/mole) acid with additions of 500 g·L−1 of zinc nitrate Zn(NO3)2∙6H2O or magnesium nitrate Mg(NO3)2∙6H2O, are described. These materials were characterized using scanning electron microscope (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS) and glow discharge optical emission spectroscopy (GDOES). It was found that the voltage of PEO process has influence on the chemical composition and thickness of the obtained porous coatings as well as on their electrochemical behavior. The higher the potential of PEO treatment, the higher the amount of zinc-to-phosphorus ratio for zinc enriched coatings was obtained, whereas in magnesium enriched coatings, the average amount of magnesium detected in PEO coating is approximately independent of the PEO voltages. Based on XPS studies, it was found out that most likely the top 10 nm of porous coatings is constructed of titanium (Ti4+), magnesium (Mg2+), zinc (Zn2+), and phosphates PO43− and/or HPO42− and/or H2PO4− and/or P2O74−. On the basis of GDOES studies, a four-sub-layer model of PEO coatings is proposed. Analysis of the potentiodynamic corrosion curves allowed to conclude that the best electrochemical repeatability was noted for magnesium and zinc enriched coatings obtained at 575 VDC.

8 September 2017 in Metals
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
SGSofia Gaiaschi
Sofia Gaiaschi
patrick chaponpatrick chapon
patrick chapon
SRSteinar Raaen
Steinar Raaen
WMWinfried Malorny
Winfried Malorny
In the paper, Scanning Electron Microscopy (SEM), Energy-dispersive X-ray Spectroscopy (EDS), X-ray Photoelectron Spectroscopy (XPS), and Glow Discharge Optical Emission Spectroscopy (GDOES) analyses of calcium- and phosphorus-enriched coatings obtained on commercial purity (CP) Titanium Grade 2 by plasma electrolytic oxidation (PEO), known also as micro arc oxidation (MAO), in electrolytes based on concentrated phosphoric acid with calcium nitrate tetrahydrate, are presented. The preliminary studies were performed in electrolytes containing 10, 300, and 600 g/L of calcium nitrate tetrahydrate, whereas for the main research the solution contained 500 g/L of the same hydrated salt. It was found that non-porous coatings, with very small amounts of calcium and phosphorus in them, were formed in the solution with 10 g/L Ca(NO3)2·4H2O, whereas the other coatings, fabricated in the consecutive electrolytes containing from 300 up to 650 g/L Ca(NO3)2·4H2O, were porous. Based on the GDOES data, it was also found that the obtained porous PEO coating may be divided into three sub-layers: the first, top, porous layer was the thinnest; the second, semi-porous layer was about 12 times thicker than the first; and the third, transition sub-layer was about 10 times thicker than the first. Based on the recorded XPS spectra, it was possible to state that the top 10-nm layer of porous PEO coatings included chemical compounds containing titanium (Ti4+), calcium (Ca2+), as well as phosphorus and oxygen (PO43− and/or HPO42− and/or H2PO4−, and/or P2O74−).

2 June 2018 in Metals
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
Wojciech KacalakWojciech Kacalak
Wojciech Kacalak
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
SRSteinar Raaen
Steinar Raaen
KPKornel Pietrzak
Kornel Pietrzak
In the paper, the effect of voltage increase (from 500 VDC up to 650 VDC) on the structure and chemical composition of the porous coating on titanium made by Plasma Electrolytic Oxidation is presented. Phosphates-based coatings enriched with calcium, magnesium, zinc, and copper in electrolyte based on 1 L of 85% concentrated H3PO4, with additions of Ca(NO3)2·4H2O, and Mg(NO3)2∙6H2O, and Zn(NO3)2∙6H2O, and Cu(NO3)2∙3H2O, are described. The morphology and chemical and phase composition are evaluated using SEM, EDS, XRD, XPS, GDOES, and CLSM. Based on these analyses, it was found that PEO coatings are porous and enriched with calcium, magnesium, zinc and copper. They consist mainly of the amorphous phase, which is more visible for higher voltages; this is correlated with an increase in the total PEO coating thickness (the higher the voltage, the thicker the PEO coating). However, for 650 VDC, an amorphous phase and titanium substrate were also recorded, with a signal from Ti2P2O7 crystalline that was not observed for lower voltages. It was also found that all obtained coatings may be divided into three sub-layers, i.e., porous, semiporous, and transitional.

2 July 2018 in Micromachines
Verified
Journal Article
Open access
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
SGSofia Gaiaschi
Sofia Gaiaschi
patrick chaponpatrick chapon
patrick chapon
SRSteinar Raaen
Steinar Raaen
KPKornel Pietrzak
Kornel Pietrzak
Coatings with developed surface stereometry, being based on a porous system, may be obtained by plasma electrolytic oxidation, PEO (micro arc oxidation, MAO). In this paper, we present novel porous coatings, which may be used, e.g., in micromachine’s biocompatible sensors’ housing, obtained in electrolytes containing magnesium nitrate hexahydrate Mg(NO3)2·6H2O and/or zinc nitrate hexahydrate Zn(NO3)2·6H2O in concentrated phosphoric acid H3PO4 (85% w/w). Complementary techniques are used for coatings’ surface characterization, such as scanning electron microscopy (SEM), for surface imaging as well as for chemical semi-quantitative analysis via energy dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), glow discharge optical emission spectroscopy (GDOES), and X-ray powder diffraction (XRD). The results have shown that increasing contents of salts (here, 250 g/L Mg(NO3)2·6H2O and 250 g/L Zn(NO3)2·6H2O) in electrolyte result in increasing of Mg/P and Zn/P ratios, as well as coating thickness. It was also found that by increasing the PEO voltage, the Zn/P and Mg/P ratios increase as well. In addition, the analysis of XPS spectra revealed the existence in 10 nm top of coating magnesium (Mg2+), zinc (Zn2+), titanium (Ti4+), and phosphorus compounds (PO43−, or HPO42−, or H2PO4−, or P2O74−).

12 February 2020 in Materials
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
Wojciech KacalakWojciech Kacalak
Wojciech Kacalak
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
SRSteinar Raaen
Steinar Raaen
ŁDŁukasz Dudek
Łukasz Dudek
To fabricate porous copper coatings on titanium, we used the process of plasma electrolytic oxidation (PEO) with voltage control. For all experiments, the three-phase step-up transformer with six-diode Graetz bridge was used. The voltage and the amount of salt used in the electrolyte were determined so as to obtain porous coatings. Within the framework of this study, the PEO process was carried out at a voltage of 450 VRMS in four electrolytes containing the salt as copper(II) nitrate(V) trihydrate. Moreover, we showed that the content of salt in the electrolyte needed to obtain a porous PEO coating was in the range 300–600 g/dm3. After exceeding this amount of salts in the electrolyte, some inclusions on the sample surface were observed. It is worth noting that this limitation of the amount of salts in the electrolyte was not connected with the maximum solubility of copper(II) nitrate(V) trihydrate in the concentrated (85%) orthophosphoric acid. To characterize the obtained coatings, numerous techniques were used. In this work, we used scanning electron microscopy (SEM) coupled with electron-dispersive X-ray spectroscopy (EDS), conducted surface analysis using confocal laser scanning microscopy (CLSM), and studied the surface layer chemical composition of the obtained coatings by X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), glow discharge of optical emission spectroscopy (GDOES), and biological tests. It was found that the higher the concentration of Cu(NO3)2∙3H2O in the electrolyte, the higher the roughness of the coatings, which may be described by 3D roughness parameters, such as Sa (1.17–1.90 μm) and Sp (7.62–13.91 μm). The thicknesses of PEO coatings obtained in the electrolyte with 300–600 g/dm3 Cu(NO3) 2∙3H2O were in the range 7.8 to 10 μm. The Cu/P ratio of the whole volume of coating measured by EDS was in the range 0.05–0.12, while the range for the top layer (measured using XPS) was 0.17–0.24. The atomic concentration of copper (0.54–0.72 at%) resulted in antibacterial and fungicidal properties in the fabricated coatings, which can be dedicated to biocompatible applications.