Łukasz Dudek

Dr. Łukasz Dudek

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2016 in Materials
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
DMDalibor Matýsek
Dalibor Matýsek
SRSteinar Raaen
Steinar Raaen
JVJan Valíček
Jan Valíček
Marta HarničárováMarta Harničárová
Marta Harničárová
In the paper, the Scanning Electron Microscopy (SEM) with Energy Dispersive X-ray Spectroscopy (EDS) and X-ray Photoelectron Spectroscopy (XPS) results of the surface layer formed on pure titanium after plasma electrolytic oxidation (micro arc oxidation) at the voltage of 450 V are shown. As an electrolyte, the mixture of copper nitrate Cu(NO3)2 (10–600 g/L) in concentrated phosphoric acid H3PO4 (98 g/mol) was used. The thickness of the obtained porous surface layer equals about 10 μm, and it consists mainly of titanium phosphates and oxygen with embedded copper ions as a bactericidal agent. The maximum percent of copper in the PEO surface layer was equal to 12.2 ± 0.7 wt % (7.6 ± 0.5 at %), which is the best result that the authors obtained. The top surface layer of all obtained plasma electrolytic oxidation (PEO) coatings consisted most likely mainly of Ti3(PO4)4∙nH3PO4 and Cu3(PO4)2∙nH3PO4 with a small addition of CuP2, CuO and Cu2O.

28 May 2020 in Materials
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
ŁDŁukasz Dudek
Łukasz Dudek
This paper shows that the subject of porous coatings fabrication by Plasma Electrolytic Oxidation (PEO), known also as Micro Arc Oxidation (MAO), is still current, inter alia because metals and alloys, which can be treated by the PEO method, for example, titanium, niobium, tantalum and their alloys, are increasingly available for sale. On the international market, apart from scientific works/activity developed at universities, scientific research on the PEO coatings is also underway in companies such as Keronite (Great Britain), Magoxid-Coat (Germany), Mofratech (France), Machaon (Russia), as well as CeraFuse, Tagnite, Microplasmic (USA). In addition, it should be noted that the development of the space industry and implantology will force the production of trouble-free micro- and macro-machines with very high durability. Another aspect in favor of this technique is the rate of part treatment, which does not exceed several dozen minutes, and usually only lasts a few minutes. Another advantage is functionalization of fabricated surface through thermal or hydrothermal modification of fabricated coatings, or other methods (Physical vapor deposition (PVD), chemical vapor deposition (CVD), sol-gel), including also reoxidation by PEO treatment in another electrolyte. In the following chapters, coatings obtained both in aqueous solutions and electrolytes based on orthophosphoric acid will be presented; therein, dependent on the PEO treatment and the electrolyte used, they are characterized by different properties associated with their subsequent use. The possibilities for using coatings produced by means of plasma electrolytic oxidation are very wide, beginning from various types of catalysts, gas sensors, to biocompatible and antibacterial coatings, as well as hard wear coatings used in machine parts, among others, used in the aviation and aerospace industries.

15 September 2016 in Surface and Interface Analysis
Verified
Journal Article
Closed access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
SRSteinar Raaen
Steinar Raaen
PCPatrick Chapon
Patrick Chapon
ŁDŁukasz Dudek
Łukasz Dudek

11 September 2018 in Materials
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
SGSofia Gaiaschi
Sofia Gaiaschi
patrick chaponpatrick chapon
patrick chapon
SRSteinar Raaen
Steinar Raaen
KPKornel Pietrzak
Kornel Pietrzak
In this paper, the characteristics of new porous coatings fabricated at three voltages in electrolytes based on H3PO4 with calcium nitrate tetrahydrate, magnesium nitrate hexahydrate, and copper(II) nitrate trihydrate are presented. The SEM, energy dispersive spectroscopy (EDS), glow discharge optical emission spectroscopy (GDOES), X-ray photoelectron spectroscopy (XPS), and XRD techniques for coating identification were used. It was found that the higher the plasma electrolytic oxidation (PEO) (micro arc oxidation (MAO)) voltage, the thicker the porous coating with higher amounts of built-in elements coming from the electrolyte and more amorphous phase with signals from crystalline Ca(H2PO4)2∙H2O and/or Ti(HPO4)2∙H2O. Additionally, the external parts of the obtained porous coatings formed on titanium consisted mainly of Ti4+, Ca2+, Mg2+ and PO43−, HPO42−, H2PO4−, P2O74− as well as Zn2+ or copper Cu+/Cu2+. The surface should be characterized by high biocompatibility, due to the presence of structures based on calcium and phosphates, and have bactericidal properties, due to the presence of zinc and copper ions. Furthermore, the addition of magnesium ions should accelerate the healing of postoperative wounds, which could lead to faster patient recovery.

1 August 2016 in Journal of Nanoscience and Nanotechnology
Verified
Journal Article
Closed access
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
ŁDŁukasz Dudek
Łukasz Dudek
DMDalibor Matýsek
Dalibor Matýsek
JVJan Valíček
Jan Valíček
Marta HarničárováMarta Harničárová
Marta Harničárová
Plasma Electrolytic Oxidation—PEO (Micro Arc Oxidation—MAO) as a surface layer modification method is increasingly being used for biomaterials. The surface after that oxidation is more biocompatible than that after other electrochemical treatments. The analyses of the titanium surface after PEO treatment show that the thickness of the surface layer is about 10 μm, and it contains oxygen (43.8 wt%), titanium (26.26 at%) and phosphorus (25.08 wt%) with some amount of copper (4.85 wt%). The depth analysis by a cross section shows there are three phases: the first one is the matrix as a pure titanium, the second one is an amorphous phase consisting of titanium (34.64 wt%), oxygen (42.13 wt%) and phosphorous (23.23 wt%), and the third outer layer composed of titanium (40.98 wt%), oxygen (40.59 wt%), phosphorus (16 wt%) and copper (2.43 wt%).

2 June 2018 in Metals
Verified
Journal Article
Open access
PDF file
Krzysztof RokoszKrzysztof Rokosz
Krzysztof Rokosz
Tadeusz HryniewiczTadeusz Hryniewicz
Tadeusz Hryniewicz
Wojciech KacalakWojciech Kacalak
Wojciech Kacalak
Katarzyna TandeckaKatarzyna Tandecka
Katarzyna Tandecka
SRSteinar Raaen
Steinar Raaen
KPKornel Pietrzak
Kornel Pietrzak
In the paper, the effect of voltage increase (from 500 VDC up to 650 VDC) on the structure and chemical composition of the porous coating on titanium made by Plasma Electrolytic Oxidation is presented. Phosphates-based coatings enriched with calcium, magnesium, zinc, and copper in electrolyte based on 1 L of 85% concentrated H3PO4, with additions of Ca(NO3)2·4H2O, and Mg(NO3)2∙6H2O, and Zn(NO3)2∙6H2O, and Cu(NO3)2∙3H2O, are described. The morphology and chemical and phase composition are evaluated using SEM, EDS, XRD, XPS, GDOES, and CLSM. Based on these analyses, it was found that PEO coatings are porous and enriched with calcium, magnesium, zinc and copper. They consist mainly of the amorphous phase, which is more visible for higher voltages; this is correlated with an increase in the total PEO coating thickness (the higher the voltage, the thicker the PEO coating). However, for 650 VDC, an amorphous phase and titanium substrate were also recorded, with a signal from Ti2P2O7 crystalline that was not observed for lower voltages. It was also found that all obtained coatings may be divided into three sub-layers, i.e., porous, semiporous, and transitional.