Malte Niklas Bongers

Prof. Dr. Malte Niklas Bongers

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
MMMohsen Malehmir
Mohsen Malehmir
DPDominik Pfister
Dominik Pfister
SGSuchira Gallage
Suchira Gallage
MSMarta Szydlowska
Marta Szydlowska
DIDonato Inverso
Donato Inverso
MHMathias Heikenwälder
Mathias Heikenwälder

24 November 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MBMalte Niklas Bongers
Malte Niklas Bongers
CSChristoph Schabel
Christoph Schabel
CTChristoph Thomas
Christoph Thomas
RRRainer Raupach
Rainer Raupach
MNMike Notohamiprodjo
Mike Notohamiprodjo
FBFabian Bamberg
Fabian Bamberg
To compare and combine dual-energy based and iterative metal artefact reduction on hip prosthesis and dental implants in CT. A total of 46 patients (women:50%,mean age:63±15years) with dental implants or hip prostheses (n = 30/20) were included and examined with a second-generation Dual Source Scanner. 120kV equivalent mixed-images were derived from reconstructions of the 100/Sn140kV source images using no metal artefact reduction (NOMAR) and iterative metal artefact reduction (IMAR). We then generated monoenergetic extrapolations at 130keV from source images without IMAR (DEMAR) or from source images with IMAR, (IMAR+DEMAR). The degree of metal artefact was quantified for NOMAR, IMAR, DEMAR and IMAR+DEMAR using a Fourier-based method and subjectively rated on a five point Likert scale by two independent readers. In subjects with hip prosthesis, DEMAR and IMAR resulted in significantly reduced artefacts compared to standard reconstructions (33% vs. 56%; for DEMAR and IMAR; respectively, p<0.005), but the degree of artefact reduction was significantly higher for IMAR (all p<0.005). In contrast, in subjects with dental implants only IMAR showed a significant reduction of artefacts whereas DEMAR did not (71%, vs. 8% p<0.01 and p = 0.1; respectively). Furthermore, the combination of IMAR with DEMAR resulted in additionally reduced artefacts (Hip prosthesis: 47%, dental implants 18%; both p<0.0001). IMAR allows for significantly higher reduction of metal artefacts caused by hip prostheses and dental implants, compared to a dual energy based method. The combination of DE-source images with IMAR and subsequent monoenergetic extrapolation provides an incremental benefit compared to both single methods.

6 December 2016 in Visceral Medicine
Verified
Journal Article
Open access
PDF file
SOSusann-Cathrin Olthof
Susann-Cathrin Olthof
A(Ahmed Othman (MD)
Ahmed Othman (MD)
SCStephan Clasen
Stephan Clasen
CSChristina Schraml
Christina Schraml
KNKonstantin Nikolaou
Konstantin Nikolaou
MBMalte Niklas Bongers
Malte Niklas Bongers
Cholangiocarcinoma (CC) is the second most common primary hepatobiliary tumour, and it is increasing in incidence. Imaging characteristics, behaviour, and therapeutic strategies in CC differ significantly, depending on the morphology and location of the tumour. In cross-sectional imaging, CCs can be classified according to the growth pattern (mass-forming, periductal infiltrating, intraductal) and the location (intrahepatic, perihilar, extrahepatic/distal). The prognosis of CC is unfavourable and surgical resection is the only curative treatment option; thus, early diagnosis (also in recurrent disease) and accurate staging including the evaluation of lymph node involvement and vascular infiltration is crucial. However, the diagnostic evaluation of CC is challenging due to the heterogeneous nature of the tumour. Diagnostic modalities used in the imaging of CC include transabdominal ultrasound, endosonography, computed tomography, magnetic resonance imaging with cholangiopancreatography, and hybrid imaging such as positron emission tomography/computed tomography. In this review, the potential of cross-sectional imaging modalities in primary staging, treatment monitoring, and detection of recurrent disease will be discussed.

2 March 2023 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
TSThomas Stein
Thomas Stein
ARAlexander Rau
Alexander Rau
MRMaximilian Frederik Russe
Maximilian Frederik Russe
PAPhilipp Arnold
Philipp Arnold
SFSebastian Faby
Sebastian Faby
JWJakob Weiß
Jakob Weiß
Background Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today’s workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. Method The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms “Photon-Counting CT”, “Photon-Counting detector”, “spectral CT”, “Computed Tomography” as well as on the authors’ experience. Results The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. Conclusion For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. Key Points: Citation Format

4 October 2023 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
FHFlorian Hagen
Florian Hagen
MSMartin Soschynski
Martin Soschynski
MWMeike Weis
Meike Weis
MHMuhammad Taha Hagar
Muhammad Taha Hagar
PKPatrick Krumm
Patrick Krumm
MHMarius Horger
Marius Horger
Background Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. Method The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms “photon-counting CT”, “photon-counting detector”, “spectral CT”, “computed tomography” as well as on the authors’ own experience. Results The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. Conclusion For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. Key Points: Citation Format

21 December 2014 in European Radiology
Verified
Journal Article
Closed access
PDF file
MBMalte Niklas Bongers
Malte Niklas Bongers
CSChristoph Schabel
Christoph Schabel
BKBernhard Krauss
Bernhard Krauss
ITIlias Tsiflikas
Ilias Tsiflikas
DKDominik Ketelsen
Dominik Ketelsen
CTChristoph Thomas
Christoph Thomas