As opposed to single-parametric ultrasonic pulse velocity measurements, a multi-parametric approach is proposed for assessment of the condition of constructional materials and early stages of its degradation. The method is based on acquisition of ultrasonic signals by stepwise profiling of the material surface at several frequencies in the range from 80 to 300 kHz. The analysis of the obtained 2D spatio-temporal waveform profiles allows us to extract case-specific parameters and features informative of deterioration. The parameters include group and phase velocities of head and surface Rayleigh waves, damping and dispersion of signals, frequency slope of attenuation, intensity distribution parameters in the spatio-temporal waveform profiles processed as images. Sensitivity of the method was confirmed in three use cases, including: a) surface quality in frost resistant concrete with rubber admixtures during freeze-thaw cycles; b) local structural deteriorations in refractory concrete subjected to high temperature; c) appearance of porosity in pultruded composite profiles due to inappropriate curing regimes.
This study aims to explore the applicability of an innovative cervical tactile ultrasound approach for predicting spontaneous preterm birth (sPTB). Eligible participants were women with low-risk singleton pregnancies in their second trimester, enrolled in this prospective observational study. A Cervix Monitor (CM) device was designed with a vaginal probe comprising four tactile sensors and a single ultrasound transducer operating at 5 MHz. The probe enabled the application of controllable pressure to the external cervical surface, facilitating the acquisition of stress-strain data from both anterior and posterior cervical sectors. These data were used to calculate cervical elasticity, as a stress-to-strain ratio. CM examination data were analyzed for 127 women at 24 - 28 gestational weeks. PTB was observed in 6.3% (8 out of 127) of the cases. The preterm group exhibited a lower average cervical stress-to-strain ratio (elasticity) of 0.70±0.26 kPa/mm compared to the term group's 1.63±0.65 kPa/mm, with a significant p-value of 1.1×10-4. Diagnostic accuracy for predicting spontaneous preterm birth based solely on cervical elasticity data was found to be 95.0% (95% CI, 88.5–100.0). These findings suggest that measuring cervical elasticity with the designed tactile ultrasound probe could potentially predict spontaneous preterm birth in a cost-effective manner.
This study investigates a novel pulsed electromagnetic field (PEMF) device for dynamic testing and structural health monitoring. The research utilises a PEMF generator CD-1501 with a maximum energy capacity of 0.5 kJ and a flat multifilament coil (IC-1) with a 100 mm diameter. Experiments were conducted on a model steel stand with two joint configurations, using steel plates of 4 mm and 8 mm thickness. The device’s efficacy was evaluated through oscillation pattern analysis and spectral characteristics. Results demonstrate the device’s ability to differentiate between joint states, with the 4 mm plate configuration showing a 15% reduction in high-frequency components compared to the 8 mm plate. Fundamental resonant frequencies of 3D-printed specimens were observed near 5100 Hz, with Q-factors ranging between 200 and 300. The study also found that a 10% increase in volumetric porosity led to a 7% downward shift in resonant frequencies. The developed PEMF device, operating at 50–230 V and delivering 1–5 pulses per minute, shows promise for rapid, non-destructive monitoring of structural joints. When combined with the coaxial correlation method, the system demonstrates enhanced sensitivity in detecting structural changes, utilising an electrodynamic actuator (10 Hz to 2000 Hz range). This integrated approach offers a 30% improvement in early-stage degradation detection compared to traditional methods.