Francesco Porcini

Dr. Francesco Porcini


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2024 in Robotics
Verified
Journal Article
Open access
PDF file
Daniele LeonardisDaniele Leonardis
Daniele Leonardis
MGMassimiliano Gabardi
Massimiliano Gabardi
SMSimone Marcheschi
Simone Marcheschi
MBMichele Barsotti
Michele Barsotti
FPFrancesco Porcini
Francesco Porcini
Antonio FrisoliAntonio Frisoli
Antonio Frisoli
Manipulation involves both fine tactile feedback, with dynamic transients perceived by fingerpad mechanoreceptors, and kinaesthetic force feedback, involving the whole hand musculoskeletal structure. In teleoperation experiments, these fundamental aspects are usually divided between different setups at the operator side: those making use of lightweight gloves and optical tracking systems, oriented toward tactile-only feedback, and those implementing exoskeletons or grounded manipulators as haptic devices delivering kinaesthetic force feedback. At the level of hand interfaces, exoskeletons providing kinaesthetic force feedback undergo a trade-off between maximum rendered forces and bandpass of the embedded actuators, making these systems unable to properly render tactile feedback. To overcome these limitations, here, we investigate a full upper limb exoskeleton, covering all the upper limb body segments from shoulder to finger phalanxes, coupled with linear voice coil actuators at the fingertips. These are developed to render wide-bandwidth tactile feedback together with the kinaesthetic force feedback provided by the hand exoskeleton. We investigate the system in a pick-and-place teleoperation task, under two different feedback conditions (visual-only and visuo-haptic). The performance based on measured interaction forces and the number of correct trials are evaluated and compared. The study demonstrates the overall feasibility and effectiveness of a complex full upper limb exoskeleton (seven limb-actuated DoFs plus five hand DoFs) capable of combined kinaesthetic and tactile haptic feedback. Quantitative results show significant performance improvements when haptic feedback is provided, in particular for the mean and peak exerted forces, and for the correct rate of the pick-and-place task.

19 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
CCCristian Camardella
Cristian Camardella
VLVittorio Lippi
Vittorio Lippi
FPFrancesco Porcini
Francesco Porcini
GBGiulia Bassani
Giulia Bassani
LLLucia Lencioni
Lucia Lencioni
AFAlessandro Filippeschi
Alessandro Filippeschi
Using lower limb exoskeletons provides potential advantages in terms of productivity and safety associated with reduced stress. However, complex issues in human–robot interactions are still open, such as the physiological effects of exoskeletons and the impact on the user’s subjective experience. In this work, an innovative exoskeleton, the Wearable Walker, is assessed using the EXPERIENCE benchmarking protocol from the EUROBENCH project. The Wearable Walker is a lower-limb exoskeleton that enhances human abilities, such as carrying loads. The device uses a unique control approach called Blend Control that provides smooth assistance torques. It operates two models simultaneously, one in the case in which the left foot is grounded and another for the grounded right foot. These models generate assistive torques combined to provide continuous and smooth overall assistance, preventing any abrupt changes in torque due to model switching. The EXPERIENCE protocol consists of walking on flat ground while gathering physiological signals, such as heart rate, its variability, respiration rate, and galvanic skin response, and completing a questionnaire. The test was performed with five healthy subjects. The scope of the present study is twofold: to evaluate the specific exoskeleton and its current control system to gain insight into possible improvements and to present a case study for a formal and replicable benchmarking of wearable robots.

7 March 2022
Verified
Conference Paper
Closed access
VLVittorio Lippi
Vittorio Lippi
AFAlessandro Filippeschi
Alessandro Filippeschi
CCCristian Camardella
Cristian Camardella
FPFrancesco Porcini
Francesco Porcini
CMChristoph Maurer
Christoph Maurer
LLLucia Lencioni
Lucia Lencioni
This work presents a description of the EXOSMOOTH project, oriented to the benchmarking of lower limb exoskeletons performance. In the field of assisted walking by powered lower limb exoskeletons, the EXOSMOOTH project proposes an experiment that targets two scientific questions. The first question is related to the effectiveness of a novel control strategy for smooth assistance. Current assist strategies are based on controllers that switch the assistance level based on the gait segmentation provided by a finite state machine. The proposed strategy aims at managing phase transitions to provide a smoother assistance to the user, thus increasing the device transparency and comfort for the user. The second question is the role of the actuation at the ankle joint in assisted walking. Many novel exoskeletons devised for industrial applications do not feature an actuated ankle joint. In the EXOSMOOTH project, the ankle joint actuation will be one experimental factor to have a direct assessment of the role of an actuated joint in assisted walking. Preliminary results of 15 healthy subjects walking at different speeds while wearing a lower limb exoskeleton supported the rationale behind this question: having an actuated ankle joint could potentially reduce the torques applied by the user by a maximum value of 85 Nm. The two aforementioned questions will be investigated in a protocol that includes walking on a treadmill and on flat ground, with or without slope, and with a load applied on the back. In addition, the interaction forces measured at the exoskeleton harnesses will be used to assess the comfort of the user and the effectiveness of the control strategy to improve transparency.

1 June 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
ESEleonora Storto
Eleonora Storto
MSMassimiliano Solazzi
Massimiliano Solazzi
MMMario Meola
Mario Meola
Antonio FrisoliAntonio Frisoli
Antonio Frisoli
FPFrancesco Porcini
Francesco Porcini
Teleultrasound is a promising application of telemedicine, enabling remote diagnostic imaging through teleoperated systems. While previous reviews have addressed various aspects such as clinical applications, autonomy levels, or assistive functionalities, a systematic analysis of teleoperation architectures—the core enabler of remote manipulation and feedback—remains lacking. This paper presents a comprehensive review of thirty-nine teleultrasound systems, focusing specifically on teleoperation architectures. Each system is examined in terms of leader and follower design, control strategies, force-feedback implementation, time delay handling, communication infrastructure, and anatomical targets. The aim of this review is the evaluation of system transparency and stability, analyzed not only in relation to devices' mechanical design and control implementation, but specifically from a comprehensive architectural point of view. Also, the evaluation critically takes into account the realism of the test conditions. Through this lens, the review shows how architectural choices critically shape the performance and safety of remote ultrasound interactions. Open challenges and future directions are also discussed, offering a reference framework for researchers and developers working on next-generation remote ultrasound technologies.

20 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ESEleonora Storto
Eleonora Storto
VNValerio Novelli
Valerio Novelli
Antonio FrisoliAntonio Frisoli
Antonio Frisoli
FPFrancesco Porcini
Francesco Porcini
Tele-ultrasound systems enable remote diagnostic imaging by transmitting both motion commands and haptic feedback between a sonographer and a robotic probe. While these systems aim to replicate conventional ultrasound procedures, they rarely address the physical strain typically experienced by sonographers. In this study, the effect of applying a force scaling strategy to haptic feedback on reducing muscular fatigue and task-induced stress during a realistic tele-ultrasound task is studied. First, a thorough operational and biomechanical analysis of the abdominal US procedure was performed to reconstruct a representative task in the laboratory. Then, a bilateral position–force tele-ultrasound architecture was implemented, and a total of 11 subjects performed the reconstructed remote ultrasound task under two randomized conditions: with and without force scaling. Surface electromyography (sEMG) signals were acquired from seven upper-limb muscles (posterior deltoid, trapezius, anterior deltoid, biceps, triceps, wrist flexors, and wrist extensors). Teleoperation-related stress was also assessed using a seven-item Likert-scale self-report questionnaire administered after each trial. Statistical significance was tested using Repeated Measures ANOVA for EMG data and the Wilcoxon signed-rank test for stress scores. The results showed a statistically significant reduction in muscle activation in 5 out of 7 muscles, and a clear mitigation of fatigue progression over time in the scaled condition. Additionally, perceived stress levels were significantly lower in the presence of force scaling in overall stress scores. These findings support the effectiveness of force scaling as a tool to enhance ergonomics in tele-ultrasound procedures without compromising the operator’s ability to perform the task. The proposed methodology proved robust and generalizable, offering valuable insight into the integration of human-centered design in tele-operated diagnostic systems.

16 August 2024 in arXiv
Verified
Preprint
Open access
PDF file
CCCristian Camardella
Cristian Camardella
VLVittorio Lippi
Vittorio Lippi
FPFrancesco Porcini
Francesco Porcini
GBGiulia Bassani
Giulia Bassani
LLLucia Lencioni
Lucia Lencioni
AFAlessandro Filippeschi
Alessandro Filippeschi
Using lower-limbs exoskeletons provides potential advantages in terms of productivity and safety associated with reduced stress. However, complex issues in human-robot interaction are still open, such as the physiological effects of exoskeletons and the impact on the user's subjective experience. In this work, an innovative exoskeleton, the Wearable Walker, is assessed using the EXPERIENCE benchmarking protocol from the EUROBENCH project. The Wearable Walker is a lower-limb exoskeleton that enhances human abilities, such as carrying loads. The device uses a unique control approach called Blend Control that provides smooth assistance torques. It operates two models simultaneously, one in the case in which the left foot is grounded and another for the grounded right foot. These models generate assistive torques combined to provide continuous and smooth overall assistance, preventing any abrupt changes in torque due to model switching. The EXPERIENCE protocol consists of walking on flat ground while gathering physiological signals such as heart rate, its variability, respiration rate, and galvanic skin response and completing a questionnaire. The test was performed with five healthy subjects. The scope of the present study is twofold: to evaluate the specific exoskeleton and its current control system to gain insight into possible improvements and to present a case study for a formal and replicable benchmarking of wearable robots.