Shahad Mohammed Altwaijri

Dr. Shahad Mohammed Altwaijri

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Materials Research Express
Verified
Journal Article
Open access
PDF file
AAAfnan Alfouzan
Afnan Alfouzan
HAHanan Alotaibi
Hanan Alotaibi
NLNawaf Labban
Nawaf Labban
STSara Mohammad Al Taweel
Sara Mohammad Al Taweel
SAShahad Mohammed Altwaijri
Shahad Mohammed Altwaijri
ETEsam A Tashkandi
Esam A Tashkandi
This study aimed to compare the effect of thickness and background on the color changes of CAD/CAM materials (zirconia-reinforced lithium silicate (Suprinity), lithium disilicate (IPS E-max CAD), and hybrid ceramic (Enamic)). Twelve specimens for each thickness (0.4 mm, 0.5 mm, 1 mm, 1.5 mm, and 2 mm) were obtained by sectioning three CAD/CAM materials. A spectrophotometer was used to measure the color change of the specimens against different backgrounds (A2 enamel, A4 dentin, gray, and metal) using the CIELab color space system. Analysis of variance, sample t-test, and posthoc multiple comparison tests were used to evaluate and compare the color changes for different material types, thicknesses, and background colors, with a significance level of P ≤ 0.05. The result demonstrated that material type, the thickness of the material, and the color of the background had a significant effect on ΔE (P = 0.000). Regardless of the material thickness, Suprinity had the highest mean ΔE values (5.4 ± 1.9), and E-max had the lowest mean ΔE values (1.1 ± 0.6). At 2 mm thickness, Enamic presented the lowest ∆E values (0.5 ± 0.5) against the A2 background. The 0.5 and 1 mm specimens corresponded to the highest ΔE values, whereas the 1.5 and 2 mm thickness specimens predominantly gave the lowest ΔE values. All the independent factors, including the type and thickness of the material, and color of the background, contributed significantly to ΔE of the tested materials (P ≤ 0.05). The study confirms the high masking ability of the lithium disilicate (E-max) material. In clinical situations where the color of the core needs to be masked, it is recommended to use lithium disilicate (E-max).

29 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
SAShahad Mohammed Altwaijri
Shahad Mohammed Altwaijri
HAHanan Alotaibi
Hanan Alotaibi
TATalal Alnassar
Talal Alnassar
AAAlhanoof Aldegheishem
Alhanoof Aldegheishem
Achieving accurate fit in implant-supported prostheses is critical for avoiding mechanical complications; however, the influence of digital manufacturing techniques and abutment designs on misfit and preload remains unclear. This study evaluated the impact of different manufacturing techniques (CAD-cast and 3D printing) and abutment connection types (engaging [E], non-engaging [NE]) on the misfit and preload of implant-supported cantilevered fixed dental prostheses (ICFDPs). Misfit was measured at six points using scanning electron microscopy, and preload was assessed via eight strain gauges placed buccally and lingually on four implants. Frameworks were torqued to 35 Ncm, retorqued after 10 min, and subjected to 200,000 cycles of loading. Mean preload values ranged from 173.4 ± 79.5 Ncm (PF) to 330 ± 253.2 Ncm (3DP). Preload trends varied depending on the abutment type and manufacturing technique, with the 3DP group showing higher preload in engaging (E) abutments, whereas the CAD-cast group showed the opposite pattern. Although preload values varied numerically, these differences were not statistically significant (p = 0.5). In terms of misfit, significant differences were observed between groups (p < 0.05), except between CAD-cast E (86.4 ± 17.8 μm) and 3DP E (84.1 ± 19.2 μm). Additionally, E and NE abutments showed significant differences in misfit within both CAD-cast and 3DP groups. Overall, 3DP frameworks showed superior fit over CAD-cast. These findings suggest that 3DP may offer improved clinical outcomes in terms of implant–abutment fit.

1 January 2022 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
SAShahad Mohammed Altwaijri
Shahad Mohammed Altwaijri
HAHanan Alotaibi
Hanan Alotaibi
TATalal Alnassar
Talal Alnassar
Altuwaijri SM, et al. J Adv Prosthodont. 2022 Feb;14(1):22-31. https://doi.org/10.4047/jap.2022.14.1.22