Sara Mohammad Al Taweel

Dr. Sara Mohammad Al Taweel


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
AAAfnan Alfouzan
Afnan Alfouzan
HAHadeel Minife Alotiabi
Hadeel Minife Alotiabi
NLNawaf Labban
Nawaf Labban
HAHanan Alotaibi
Hanan Alotaibi
STSara Mohammad Al Taweel
Sara Mohammad Al Taweel
HAHuda Ahmed Alshehri
Huda Ahmed Alshehri
Alfouzan AF, et al. J Adv Prosthodont. 2021 Jun;13(3):160-171. https://doi.org/10.4047/jap.2021.13.3.160

15 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
AAAfnan Alfouzan
Afnan Alfouzan
MTMalath Tuwaym
Malath Tuwaym
EAEbthal Aldaghri
Ebthal Aldaghri
TATagreed Alojaymi
Tagreed Alojaymi
HAHadeel Alotiabi
Hadeel Alotiabi
NLNawaf Labban
Nawaf Labban
This study assessed the efficacy of five denture cleansers on the microbial adherence and surface topography of conventional and CAD/CAM denture base resins. Acrylic resin discs were fabricated using conventional, milling, and 3D printing methods (N = 180). The discs were contaminated with dual species of Candida albicans and Streptococcus mutans biofilm for 72 h and then disinfected with either of the denture cleansers (Fittydent cleansing tablets, 2% Chlorhexidine gluconate, 0.2% Chlorhexidine gluconate, 0.5% sodium hypochlorite, and 1% sodium hypochlorite (n = 10). Distilled water served as the control group. The colony-forming units of the microorganisms were calculated, followed by post-treatment surface roughness. Data were statistically analyzed using one-way ANOVA, paired t-test, and post hoc Tukey HSD test (α = 0.05). Among the denture cleansers, 2% Chlorhexidine gluconate, 0.5% sodium hypochlorite, and 1% sodium hypochlorite had the best cleansing effect on the resin discs and demonstrated zero growth of colonies for both the species. Comparing the material groups, the 3D-processed discs showed higher colony-forming units followed by the conventional and CAD/CAM milled group. The highest surface roughness was demonstrated by the 3D-printed discs (0.690 ± 0.08 μm), followed by the conventional (0.493 ± 0.11 μm) and the milled groups (0.301 ± 0.08 μm). The tested chemical denture cleansers affected the Candida albicans and Streptococcus mutans adhesion compared to control discs immersed in distilled water. The clinician may recommend to their patient to use 2% chlorhexidine gluconate for the disinfection of CAD/CAM PMMA denture base materials.

3 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
STSara Mohammad Al Taweel
Sara Mohammad Al Taweel
HAHanan Alotaibi
Hanan Alotaibi
NLNawaf Labban
Nawaf Labban
AAAfnan Alfouzan
Afnan Alfouzan
HAHuda Ahmed Alshehri
Huda Ahmed Alshehri
This study aimed to evaluate the airborne-particle abrasion surface treatment effects on the tensile bond strength (TBS) between resilient denture liner and CAD/CAM or conventional heat polymerized poly (methyl methacrylate) (PMMA) acrylic denture resins. A total of 48 dumbbell-shaped specimens (70 mm in total length, and 12 mm and 7 mm in diameter at the thickest and thinnest section, respectively) were prepared from CAD/CAM and conventional acrylic resins. Before relining with denture liner, 12 specimens from each material were surface-treated by 110 µm Al2O3 airborne-particle abrasion, and the remaining specimens served as control (no treatment). Following relining, all the specimens were aged by thermal cycling (1000 cycles, 5–55 °C). The TBS of denture liner to acrylic denture resins was tested in a universal testing apparatus at a 5 mm/min crosshead speed. The debonded surfaces were visually examined for the failure modes. ANOVA and multiple comparisons posthoc analysis tests were applied to determine the significant difference in TBS between the study groups (α = 0.05). A significant difference in TBS was observed between the control and surface treated groups (p < 0.001) for both acrylic resins materials. However, there was no statistically significant difference in bond strength between the acrylic resins materials (p = 0.739). Surface treatment with airborne-particle abrasion demonstrated increased TBS of the soft denture liners to acrylic resins. The TBS of conventional and CAD/CAM acrylic resins to soft denture liners were not considerably different.

1 December 2021 in Materials Research Express
Verified
Journal Article
Open access
PDF file
STSara Mohammad Al Taweel
Sara Mohammad Al Taweel
AAAfnan Alfouzan
Afnan Alfouzan
HAHanan N Al-Otaibi
Hanan N Al-Otaibi
NLNawaf Labban
Nawaf Labban
HAHuda Ahmed Alshehri
Huda Ahmed Alshehri
The aim of the present study was to evaluate and compare the effect of thermal-cycling, mechanical brushing and beverage storage on the colour changes and surface roughness of conventional heat-polymerized and CAD/CAM PMMA used to fabricate complete dentures. A total of 100 specimens measuring 10 mm in diameter and 3 mm in thickness were fabricated from conventional PMMA resin (Heat-cured, Major. Base.20, Moncalieri, Italy) and CAD/CAM blocks (Opera system, Principauté de Monaco, French). The specimens were subjected to a combined surface treatment involving thermo-cycling, mechanical brushing, and immersed in either artificial saliva (AS), coffee, tea, Coca-Cola, or lemon juice. Colour differences (ΔE) and surface roughness (Ra) was determined using a spectrophotometer and non-contact profilometer, respectively. The data were analyzed using IBM SPSS v.20 (α = 0.05). Factorial ANOVA showed that independent factors, namely material, beverages, and the interaction between independent factors, significantly influenced ΔE (F = 76.862; p < 0.001) and surface roughness (F = 71.685; p < 0.001). The overall highest and lowest colour differences was obtained for CAD/CAM PMMA (ΔE = 1.93 ± 1.29) and conventional PMMA (ΔE = 1.41 ± 1.39) resins, respectively (p = 0.061). Conventional PMMA (1.22 ± 0.20) demonstrated significantly increased roughness compared to CAD/CAM PMMA (0.91 ± 0.17) (p < 0.001). Pearson correlation showed a low degree of correlation, which was non-significant for both the PMMA (r = 0.015; p = 0.917) and C-PMMA materials (r = 0.097; p = 0.505). CAD/CAM milled PMMA resins demonstrated greater colour change and lower surface roughness compared to conventional heat-polymerized PMMA resins. Specimens in tea and coffee demonstrated maximum colour changes and were perceivable by the human eye. On the contrary, specimens immersed in low pH acidic beverages namely Coca-Cola and lemon juice demonstrated maximum surface roughness.

1 May 2020 in Materials Research Express
Verified
Journal Article
Open access
PDF file
AAAfnan Alfouzan
Afnan Alfouzan
HAHanan Alotaibi
Hanan Alotaibi
NLNawaf Labban
Nawaf Labban
STSara Mohammad Al Taweel
Sara Mohammad Al Taweel
SAShahad Mohammed Altwaijri
Shahad Mohammed Altwaijri
ETEsam A Tashkandi
Esam A Tashkandi
This study aimed to compare the effect of thickness and background on the color changes of CAD/CAM materials (zirconia-reinforced lithium silicate (Suprinity), lithium disilicate (IPS E-max CAD), and hybrid ceramic (Enamic)). Twelve specimens for each thickness (0.4 mm, 0.5 mm, 1 mm, 1.5 mm, and 2 mm) were obtained by sectioning three CAD/CAM materials. A spectrophotometer was used to measure the color change of the specimens against different backgrounds (A2 enamel, A4 dentin, gray, and metal) using the CIELab color space system. Analysis of variance, sample t-test, and posthoc multiple comparison tests were used to evaluate and compare the color changes for different material types, thicknesses, and background colors, with a significance level of P ≤ 0.05. The result demonstrated that material type, the thickness of the material, and the color of the background had a significant effect on ΔE (P = 0.000). Regardless of the material thickness, Suprinity had the highest mean ΔE values (5.4 ± 1.9), and E-max had the lowest mean ΔE values (1.1 ± 0.6). At 2 mm thickness, Enamic presented the lowest ∆E values (0.5 ± 0.5) against the A2 background. The 0.5 and 1 mm specimens corresponded to the highest ΔE values, whereas the 1.5 and 2 mm thickness specimens predominantly gave the lowest ΔE values. All the independent factors, including the type and thickness of the material, and color of the background, contributed significantly to ΔE of the tested materials (P ≤ 0.05). The study confirms the high masking ability of the lithium disilicate (E-max) material. In clinical situations where the color of the core needs to be masked, it is recommended to use lithium disilicate (E-max).

30 March 2023 in Polimery
Verified
Journal Article
Open access
PDF file
HAHanan Alotaibi
Hanan Alotaibi
RBRafal Basaqer
Rafal Basaqer
SASarah Almania
Sarah Almania
AAAfnan Alfouzan
Afnan Alfouzan
STSara Mohammad Al Taweel
Sara Mohammad Al Taweel
NLNawaf Labban
Nawaf Labban
The study evaluated the effect of different acidic salivary pH values on monomer leaching and surface roughness of conventional and CAD/CAM processed (milled and 3D-printed) denture base materials. High-performance liquid chromatography was used to determine the quantity of residual methyl methacrylate monomer leaching after 30 days of immersion in acidic saliva. The surface roughness (Ra) before and after incubation was recorded using a non-contact optical profilometer. The monomer leaching and the surface roughness of the tested materials depended on the pH value of the saliva. The conventional denture framework material exhibited the highest and lowest leaching rates at pH=4.5 and pH=3.5, respectively, regardless of the treatment method. Among the CAD/CAM processed materials, the 3D-printed material showed the highest and lowest leaching at pH=5.5 and pH=3.5, respectively. Regardless of the pH, roughness after incubation was the lowest for conventional materials, and the highest for 3D printing.