Purpose: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. Methods: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. Results: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. Conclusions: Our data suggest that VMI at 60–70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.
Background and purpose: The complex anatomy of the temporal bone is difficult to understand and constitutes a challenge in the daily diagnostic routine even for experienced neuroradiologists. In the context of otoneurological (oVEMP) and preoperative diagnostics, the diagnosis of superior semicircular canal dehiscence (SSCD) is of great importance for Ear, Nose, and Throat (ENT) specialists. The gold standard for this diagnosis is a high-resolution CT (HRCT) of the temporal bone. In order to correctly diagnose SSCD, special oblique reconstructions are necessary in addition to standard (axial, coronal, sagittal) reconstructions. We evaluated the frequency of diagnosis and its location in HRCT in correlation with otoneurological examination. From this analysis, we present a new SSCD classification. This classification yields the potential of a differentiated analysis of the patient’s clinical symptoms with correlation to the cross-sectional anatomy and may lead to a differentiated therapy approach. Study design and setting: We evaluated 1370 temporal bone scans of patients with residual hearing and verified 343 superior semicircular canal dehiscence (SSCD). We conducted a subgroup analysis of these 343 HRCT scans displaying a SSCD and used them as a basis to create a classification. Results: Three location types of SSCD were identified. These were anterior type 1, superior type 2 and posterior type 3. Type 2 were significantly more frequent in both sexes. SSCD at this location can be overlooked if diagnosis is performed only in the standard axial plane, since it can only be visualized by means of double oblique reconstruction. We present a standardized reconstruction algorithm. Conclusion: In total, three types of SSCD with differing incidences can be extrapolated from the locations. Superior type 2 is the most frequent one. Both sexes are affected with roughly equal incidence. The use of standardized double oblique reconstruction algorithm ensures that all three types are diagnosed in the HRCT.
Background: The aim of this study was to compare three different methods for measurement of cochlear duct length (CDL) in the clinical setting for two different imaging modalities, namely computed tomography (CT) and cone-beam computed tomography (CBCT). Patients and Methods: One hundred temporal bone data sets (CT: n=50; CBCT: n=50) of non-malformed cochleae were retrospectively analyzed using three different CDL estimation techniques: 3D curved multiplanar reconstruction (cMPR), 2D cMPR and the A-value formula. Results: The data sets belonged to 60 patients (34 males, 26 females; mean age=50.28±18.58 years). For both imaging modalities, application of the 3D cMPR estimation technique led to significantly greater mean CDL values than the two-dimensional methods (p<0.0083). The CDL measurements viewed in CT imaging software were significantly shorter than the corresponding CBCT measurements (p<0.05). Using a linear mixed model, differences in CDL by sex (p=0.796), age (p=0.377) and side of ear (p=0.690) were not significant. Conclusion: The 3D cMPR technique was found to provide the most accurate in vivo CDL measurement in non-malformed cochlea in both CT and CBCT imaging compared to 2D methods. The study results also suggest that the higher spatial resolution in CBCT imaging results in more precise CDL determination than in CT.
Objectives: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. Materials & Methods: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. Results: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (p < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (p < 0.001) except for 50 keV (p > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60–70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. Conclusions: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40–50 keV.
Purpose: Cochlea implant surgery with proper positioning of the cochlear electrode can be challenging. Intraoperative real-time hybrid laser-fluoroscopic-guided navigation based on a multiplanar cone beam computed tomography (CBCT) dataset opens up the opportunity to immediate radiological control of primary electrode misalignments and offering new insights into the cochlea electrode insertion routes and favorable cochlear implant-insertion angle. Methods: In this retrospective study, 50 cases (29 males, 18 females) of conventional electrode implantation (without intraoperative image control; group A) and nine cases (7 males, 2 females) of CBCT-laser-fluoroscopic-guided surgery (group B) were included in the present study. CBCT-laser-guided surgery under real-time fluoroscopic control was conducted using an intraoperative C-arm CBCT. All patients received preoperative cross-sectional imaging (CT and MRI), in which cochlear malformation could be excluded. Postoperatively, we looked for electrode misplacements. Results: In group A, electrode misalignment was detected postoperatively in 14 of 50 cases (28.0%). In group B, primary electrode misalignment was detected intraoperatively in two patients (22.2%). In both patients, the misalignments were corrected in the same session. The comparison of cochlear insertion angles showed significant differences. Group A: 47.5 ± 2.6° (actual conventional surgery) vs 17.6 ± 2.8° (theoretical CBCT-laser-fluoroscopic-guided surgery) P < 0.001. Group A vs group B: 47.5 ± 2.6° (actual conventional surgery; Group A) vs 17.9 ± 2.5° (actual CBCT-laser-fluoroscopic-guided surgery; Group B) P < 0.001. Conclusion: We consider that an intraoperative hybrid CBCT-laser-fluoroscopic-controlled approach in cochlear implant surgery using a C-arm CT can be beneficial, because electrode misalignments can be reduced and if it does occur, remedied in the same surgical session.