Daniel Overhoff

Dr. Daniel Overhoff

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MSMartin Soschynski
Martin Soschynski
FHFlorian Hagen
Florian Hagen
SBStefan Baumann
Stefan Baumann
MHMuhammad Taha Hagar
Muhammad Taha Hagar
JWJakob Weiss
Jakob Weiss
PKPatrick Krumm
Patrick Krumm
The aim of this paper is to evaluate the diagnostic image quality of spectral dual-source photon-counting detector coronary computed tomography angiography (PCD-CCTA) for coronary artery disease in a multicenter study. The image quality (IQ), assessability, contrast-to-noise ratio (CNR), Agatston score, and radiation exposure were measured. Stenoses were quantified and compared with invasive coronary angiography, if available. A total of 92 subjects (65% male, age 58 ± 14 years) were analyzed. The prevalence of significant coronary artery disease (CAD) (stenosis ≥ 50%) was 17% of all patients, the range of the Agatston score was 0–2965 (interquartile range (IQR) 0–135). The IQ was very good (one, IQR one–two), the CNR was very high (20 ± 10), and 5% of the segments were rated non-diagnostic. The IQ and assessability were higher in proximal coronary segments (p < 0.001). Agatston scores up to 600 did not significantly affect the assessability of the coronary segments (p = 0.3). Heart rate influenced assessability only at a high-pitch mode (p = 0.009). For the invasive coronary angiography (ICA) subgroup (n = nine), the diagnostic performance for CAD per segment was high (sensitivity 92%, specificity 96%), although the limited number of patients who underwent both diagnostic modalities limits the generalization of this finding at this stage. PCD-CCTA provides good image quality for low and moderate levels of coronary calcifications.

1 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Daniel DillingerDaniel Dillinger
Daniel Dillinger
DODaniel Overhoff
Daniel Overhoff
CBChristian Booz
Christian Booz
HKHanns Leonhard Kaatsch
Hanns Leonhard Kaatsch
JPJoel Piechotka
Joel Piechotka
SWStephan Waldeck
Stephan Waldeck
Purpose: The novel photon-counting detector (PCD) technique acquires spectral data for virtual monoenergetic imaging (VMI) in every examination. The aim of this study was the evaluation of the impact of VMI of abdominal arterial vessels on quantitative and qualitative subjective image parameters. Methods: A total of 20 patients that underwent an arterial phase computed tomography (CT) scan of the abdomen with a novel PCD CT (Siemens NAEOTOM alpha) were analyzed regarding attenuation at different energy levels in virtual monoenergetic imaging. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated and compared between the different virtual monoenergetic (VME) levels with correlation to vessel diameter. In addition, subjective image parameters (overall subjective image quality, subjective image noise and vessel contrast) were evaluated. Results: Our research showed decreasing attenuation levels with increasing energy levels in virtual monoenergetic imaging regardless of vessel diameter. CNR showed best overall results at 60 keV, and SNR at 70 keV with no significant difference to 60 keV (p = 0.294). Subjective image quality was rated best at 70 keV for overall image quality, vessel contrast and noise. Conclusions: Our data suggest that VMI at 60–70 keV provides the best objective and subjective image quality concerning vessel contrast irrespective of vessel size.

2 March 2023 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
TSThomas Stein
Thomas Stein
ARAlexander Rau
Alexander Rau
MRMaximilian Frederik Russe
Maximilian Frederik Russe
PAPhilipp Arnold
Philipp Arnold
SFSebastian Faby
Sebastian Faby
JWJakob Weiß
Jakob Weiß
Background Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today’s workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. Method The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms “Photon-Counting CT”, “Photon-Counting detector”, “spectral CT”, “Computed Tomography” as well as on the authors’ experience. Results The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. Conclusion For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. Key Points: Citation Format

4 October 2023 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
FHFlorian Hagen
Florian Hagen
MSMartin Soschynski
Martin Soschynski
MWMeike Weis
Meike Weis
MHMuhammad Taha Hagar
Muhammad Taha Hagar
PKPatrick Krumm
Patrick Krumm
MHMarius Horger
Marius Horger
Background Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. Method The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms “photon-counting CT”, “photon-counting detector”, “spectral CT”, “computed tomography” as well as on the authors’ own experience. Results The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. Conclusion For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. Key Points: Citation Format

21 June 2022 in Tomography
Verified
Journal Article
Open access
PDF file
SWStephan Waldeck
Stephan Waldeck
DODaniel Overhoff
Daniel Overhoff
Leona S. AlizadehLeona S. Alizadeh
Leona S. Alizadeh
BBBenjamin Becker
Benjamin Becker
MPMatthias Port
Matthias Port
SSSandra Schmidt
Sandra Schmidt
Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, the photon-counting detector (PCD-CT) is a new emerging technology with the potential to eliminate these problems. This study evaluated the performance of virtual monoenergetic (VME) EID-CT images versus PCD-CT in CI imaging. In this cadaveric study, two temporal bone specimens with implanted CIs were scanned with EID-CT and PCD-CT. The images were assessed according to the visibility of interelectrode wire, size of electrode contact, and diameter of halo artifacts. The visibility of interelectrode wire sections was significantly higher when reviewing PCD-CT images. The difference in diameter measurements for electrode contacts between the two CT scanner modalities showed that the PCD-CT technology generally led to significantly larger diameter readings. The larger measurements were closer to the manufacturer’s specifications for the CI electrode. The size of halo artifacts surrounding the electrode contacts did not differ significantly between the two imaging modalities. PCT-CT imaging is a promising technology for CI imaging with improved spatial resolution and better visibility of small structures than conventional EID-CT.

23 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
IAIsabelle Ayx
Isabelle Ayx
HTHishan Tharmaseelan
Hishan Tharmaseelan
AHAlexander Hertel
Alexander Hertel
DNDominik Nörenberg
Dominik Nörenberg
DODaniel Overhoff
Daniel Overhoff
MFMatthias F. Frölich
Matthias F. Frölich
The implementation of radiomics-based, quantitative imaging parameters is hampered by a lack of stability and standardization. Photon-counting computed tomography (PCCT), compared to energy-integrating computed tomography (EICT), does rely on a novel detector technology, promising better spatial resolution and contrast-to-noise ratio. However, its effect on radiomics feature properties is unknown. This work investigates this topic in myocardial imaging. In this retrospective, single-center IRB-approved study, the left ventricular myocardium was segmented on CT, and the radiomics features were extracted using pyradiomics. To compare features between scanners, a t-test for non-paired samples and F-test was performed, with a threshold of 0.05 set as a benchmark for significance. Feature correlations were calculated by the Pearson correlation coefficient, and visualization was performed with heatmaps. A total of 50 patients (56% male, mean age 56) were enrolled in this study, with equal proportions of PCCT and EICT. First-order features were, nearly, comparable between both groups. However, higher-order features showed a partially significant difference between PCCT and EICT. While first-order radiomics features of left ventricular myocardium show comparability between PCCT and EICT, detected differences of higher-order features may indicate a possible impact of improved spatial resolution, better detection of lower-energy photons, and a better signal-to-noise ratio on texture analysis on PCCT.