Weidong Xiao

Dr. Weidong Xiao

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2007 in IEEE Industrial Electronics Magazine
Verified
Journal Article
Closed access
WXWeidong Xiao
Weidong Xiao
NONathan Ozog
Nathan Ozog
WDWilliam G. Dunford
William G. Dunford
This paper looks at the performance of photovoltaic modules in nonideal conditions and proposes topologies to minimize the degradation of performance caused by these conditions. It is found that the peak power point of a module is significantly decreased due to only the slightest shading of the module, and that this effect is propagated through other nonshaded modules connected in series with the shaded one. Based on this result, two topologies for parallel module connections have been outlined. In addition, dc/dc converter technologies, which are necessary to the design, are compared by way of their dynamic models, frequency characteristics, and component cost. Out of this comparison, a recommendation has been made

18 September 2013 in IEEE Industrial Electronics Magazine
Verified
Journal Article
Closed access
Enrique Romero-CadavalEnrique Romero-Cadaval
Enrique Romero-Cadaval
Giovanni SpagnuoloGiovanni Spagnuolo
Giovanni Spagnuolo
LFLeopoldo Franquelo
Leopoldo Franquelo
CRCarlos Andres Ramos-Paja
Carlos Andres Ramos-Paja
TSTeuvo Suntio
Teuvo Suntio
WXWeidong Xiao
Weidong Xiao
The main design objective of photovoltaic (PV) systems has been, for a long time, to extract the maximum power from the PV array and inject it into the ac grid. Therefore, the maximum power point tracking (MPPT) of a uniformly irradiated PV array and the maximization of the conversion efficiency have been the main design issues. However, when the PV plant is connected to the grid, special attention has to be paid to the reliability of the system, the power quality, and the implementation of protection and grid synchronization functions. Modern power plants are required to maximize their energy production, requiring suitable control strategies to solve the problems related to the partial shading phenomena and different orientation of the PV modules toward the sun. Moreover, the new policy concerning the injection of reactive power into the grid makes the development of suitable topologies and control algorithms mandatory. A general view of actual solutions for applications of the PV energy systems is presented. This article covers several important issues, including the most reliable models used for simulation, which are useful in the design of control systems, and the MPPT function, particularly in distributed applications. The main topologies used in the PV power processing system and, finally, grid connection aspects are discussed, with emphasis on synchronization, protections, and integration.

10 April 2007 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WXWeidong Xiao
Weidong Xiao
WDWilliam G. Dunford
William G. Dunford
PPPatrick R. Palmer
Patrick R. Palmer
ACAntoine Capel
Antoine Capel
In photovoltaic power systems, both photovoltaic modules and switching-mode converters present nonlinear and time-variant characteristics, which result in a difficult control problem. This paper presents an in-depth analysis and modeling to discover the inherent features of a photovoltaic power system. The method of successive linearization simplifies the nonlinear problem back to the linear case. This paper also presents the use of Youla parameterization to design a stable control system for regulating the photovoltaic voltage. The experimental and simulation results demonstrate the effectiveness of the presented analysis, design, and implementation.

26 June 2012 in IEEE Transactions on Vehicular Technology
Verified
Journal Article
Closed access
HWHuiqing Wen
Huiqing Wen
WXWeidong Xiao
Weidong Xiao
XWXuhui Wen
Xuhui Wen
PAPeter Armstrong
Peter Armstrong
In electric vehicle (EV) inverter systems, direct-current-link capacitors, which are bulky, heavy, and susceptible to degradation from self heating, can become a critical obstacle to high power density. This paper presents a comprehensive method for the analysis and comparative evaluation of dc-link capacitor applications to minimize the volume, mass, and capacitance. Models of equivalent series resistance that are valid over a range of frequency and operating temperature are derived and experimentally validated. The root-mean-square values and frequency spectra of the capacitor current are analyzed with respect to three modulation strategies and various operating conditions over practical ranges of load power factor and modulation index in EV drive systems. The modeling and analysis also consider the self-heating process and resulting core temperature of the dc-link capacitors, which impacts their lifetimes. Based on an 80-kW permanent-magnet (PM) motor drive system, the application of electrolytic capacitors and film capacitors has been evaluated by both simulation and experimental tests. The inverter power density is improved from 2.99 kW/L to 13.3 kW/L, without sacrificing the system performance in terms of power loss, core temperature, and lifetime.

1 April 2013 in Applied Energy
Verified
Journal Article
Closed access
PZPeng Zhang
Peng Zhang
WLWenyuan Li
Wenyuan Li
SLSherwin Li
Sherwin Li
YWYang Wang
Yang Wang
WXWeidong Xiao
Weidong Xiao

13 August 2012 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
VPV. Ravikumar Pandi
V. Ravikumar Pandi
HZH. H. Zeineldin
H. H. Zeineldin
WXWeidong Xiao
Weidong Xiao
In this paper, a new optimization problem is proposed to determine the maximum distributed generation (DG) penetration level by optimally selecting types, locations and sizes of utility owned DG units. The DG penetration level could be limited by harmonic distortion because of the nonlinear current injected by inverter-based DG units and also protection coordination constraints because of the variation in fault current caused by synchronous-based DG units. Hence the objective of the proposed problem is to maximize DG penetration level from both types of DG units, taking into account power balance constraints, bus voltage limits, total and individual harmonic distortion limits specified by the IEEE-519 standard, over-current relay operating time limits, and protection coordination constraints. The DG penetration study is formulated as a nonlinear programming (NLP) problem and tested on the IEEE-30 bus looped distribution network with ten load and DG scenarios. Similarly, feasibility assessment of customer owned DG unit installations considering power quality and protection coordination is also studied. Simulation results show the effectiveness of the proposed approach, which can serve as an efficient planning tool for utility operators.