Although biofloc technology (BFT) currently offers advantages such as improving aquaculture water quality, providing natural bait for cultured animals, and reducing pests and diseases, single BFT systems face technical bottlenecks, including the complex regulation of the carbon–nitrogen ratio, accumulation of suspended substances, and acidification of the bottom sludge. Therefore, constructing a composite system with complementary functions through technology integration, such as with aquaponics, biofilm technology, integrated multi-trophic aquaculture systems (IMTAs), and recirculating aquaculture systems (RASs), has become the key path to breaking through industrialization barriers. This paper systematically reviews the action mechanisms, synergistic effects, and challenges of the four mainstream integration models incorporating BFT, providing theoretical support for the environmental–economic balance of intensive aquaculture.
The distribution of airflow field in the pneumatic centralized cylinder metering device cavity, airstream distributor and different angle seed feeding tubes was investigated based on the pneumatic centralized cylinder direct-seeding metering device to study the effect on the movement law of rice seed. In total, three suction hole sizes (1.5 mm, 2 mm and 2.0 mm 45° wedge) were used for CFD simulation. The results showed that under the same inlet vacuum, the pressure at the 1.5 mm hole is higher than the other two types of holes, and the five measurement points of the 2 mm hole are more stable than the other two types of holes. At the positive pressure seed feeding area, the inlet pressure was set as 1.5 kPa, and the outlet pressure was set as 0 Pa. The pressure distribution at different measuring points showed that the 2 mm 45° wedge had the most uneven positive pressure distribution, and the 1.5 mm hole had higher positive pressure distribution than the 2 mm hole in general. Three different structured airflow distributors were designed. CFD simulation experiments showed that the arc transition type presented better uniformity than the other two types. The uniformity experiments at the ends of the seed-feeding tubes indicated that the airflow velocity had the trend of large in the middle and small at two sides. Finally, the movement law of the rice seeds in seed feeding tubes at different angles was obtained by using high-speed photography. The results showed that the rice seeds in tube C (maximum angle) presented a movement posture of falling sector a and kept falling after colliding in sector b; the rice seeds in tube B (the second angle) presented a movement posture of falling in sector a and kept falling after colliding in sector b. The above research provides a reference for the optimal design of a pneumatic centralized cylinder metering device.
Low organic carbon utilization efficiency is a core bottleneck restricting the application of biofloc technology (BFT) in intensive aquaculture, accompanied by limited total nitrogen removal, excessive biofloc accumulation, and underutilized chemical energy in organic wastes. To address this issue, this study develops a novel biofloc technology–microbial fuel cell (BFT-MFC) coupled system that exploits surplus carbon sources in BFT as electron donors for bioelectricity generation while synergistically enhancing water purification performance. Compared with a conventional standalone BFT system, the coupled system was systematically evaluated in terms of water quality regulation, biofloc control and electricity generation performance. Results showed that the BFT-MFC system maintained relatively stable dissolved oxygen, pH, and temperature throughout the operation period. The ammonia nitrogen concentration remained relatively low in the BFT-MFC system, although a transient increase to approximately 0.35 mg/L occurred around day 20 before subsequently declining, and total nitrogen fluctuated within 4.29–12.87 mg/L, with substantially less accumulation than that observed in the BFT system, in contrast to the control group, where TN continuously rose to a peak of 23.55 mg/L. Total organic carbon was stabilized within a narrower range of 150–245 mg/L, compared with the wide fluctuation of 129.6–360 mg/L in the single BFT system. Additionally, the coupled system exhibited lower net biofloc accumulation based on floc-volume measurements, while maintaining effective water-quality regulation, and the integrated MFC delivered a maximum output voltage of 295.9 mV and a peak power density of 1716.8 mW m−2. Overall, the BFT-MFC coupled system integrates wastewater purification, biofloc regulation and energy recovery into a single unit, offering a promising sustainable strategy for industrial recirculating aquaculture.