When it comes to the deep soft soil foundation, improper construction, preloading, and excavation may result in the inclination of the pre-stressed concrete pipe (PCP) piles. Lack of understanding on deformation characteristics may lead to inaccurate reinforcement plan, thereby causing new engineering accidents. This study analyzes an engineering accident induced by the pile inclination, based on which the finite element method model is built. Deformation characteristics of the foundation incorporating inclined PCP piles are investigated, and the reinforcement program involving placement of the pile with opposite inclination is proposed and compared with the conventional reinforcement program using vertical piles. Findings of this study are two-folds: 1) A critical inclination angle affecting the vertical settlement exists, below which the pile inclination has limited effects upon the vertical load bearing capacity of the foundation. 2) The vertical subsidence, the lateral displacement and the bending moment of the reinforcement program based on the reversely inclined pile are all decreased, which helps bear the overburden load and improve stability. In the process of engineering accident treatment, the bearing capacity of PCP piles with small inclination angles can be first reduced according to their inclination angles, followed by judgement that whether these PCP piles meet the requirements on bearing capacity. The PCP piles with large inclination angles must be strengthened, and the reverse inclined PCP piles are recommended.
The embankment slope is vulnerable to slip and collapse, when prestressed concrete pipe (PCP) piles are used to reinforce the inclined soft foundation to bear the load of the embankment. Accordingly, this study puts forward new programs for strengthening embankment foundation with inclined, rather than vertical, PCP piles. Based on an actual engineering accident with embankment slope collapse, this study establishes a finite element model, accompanied by analysis of engineering characteristics and reinforcement effects of the foundation. The main conclusions are drawn as follows: (1) when a pile‐supported foundation is used to strengthen the inclined soft foundation, PCP piles in the lower part of the embankment are subjected to bending moments, with their maximum value appearing in the upper part of the PCP pile at the embankment slope foot. During the embankment filling, the maximum pile bending moment may reach the ultimate bending load, resulting in bending failure accompanied with large lateral displacement and even slope collapse. The maximum horizontal displacement of the foundation is located at the foot of the embankment slope. (2) Reinforcement using inclined PCP piles contributes to smaller maximum pile body bending moments than that using vertical PCP piles and loading berms, and such contribution is enhanced when the inclination angle of PCP piles in the lower part of the slope gets larger. Therefore, inclined PCP piles with high angles are optimum in improving the overall stability of the foundation. (3) Compared with vertical PCP piles, inclined PCP piles contribute to smaller horizontal displacement and vertical settlement in foundation reinforcement, which means better reinforcement effects. Moreover, as the inclination angle of PCP piles increases, the maximum displacement decreases rapidly, associated with greatly enhanced lateral stability.
Under vertical load, the composite foundation may be damaged due to insufficient lateral restraint capacity. If the lateral restraint pile is added to the edge of the composite foundation, the lateral stability can be effectively enhanced. This new reinforcement scheme is called a combined composite foundation. For the combined composite foundation, the lateral restraint piles will bear a certain force when the composite foundation is loaded, and the force may cause the piles horizontal displacement, instability, or even failure. After preload on the composite foundation, the mechanical behavior of lateral restraint piles will be more sophisticated. To study the mechanical behavior of lateral restraint piles under such condition, a laboratory model test was conducted. The results are suggested as follows: Axial force distribution curves tend to be S shape with two peak values at the upper and lower parts, respectively. The negative axial force is distributed at the upper part, and the positive axial force is distributed at the lower part. The bending moment and lateral soil pressure distribution of piles appear with the regularity of increase-decrease along the depth. Such a phenomenon is associated with the expansion of a potential slip surface. In accordance with the relative location of the potential slide surface and the piles, the lateral restraint piles can fall into three sections. Different sections get different stresses. The reinforcement scopes have an impact on the stress of different lateral restraint piles. With the increase of the reinforcement scope, the axial force, soil pressure, and bending moment show the regularity of increase. The values of axial force, the lateral soil pressure, and the bending moment increase with load growth and become stable when the load is larger than 60kN. This is associated with the piles in the composite foundation, which verifies the reinforcement effect to prevent the soil slide and the foundation deformation.
A new type of thorn pile is proposed to address the poor bearing capacity of the foundation. The design of five thorn piles is presented, and the numerical simulation of pile–soil interaction under a uniform silt foundation is performed using ABAQUS software. The influence of thorn shape on the compressive bearing capacity of thorn piles is elucidated, and the mechanism of thorn structure on the soil around piles is analyzed. The results showed that the thorn pile can significantly increase pile shaft resistance and reduce pile top settlement compared with the smooth pile. The ultimate bearing capacity of the 5# pile is 1.6 times higher than that of the smooth pile, while the pile top settlement is reduced by 82.9%. The addition of a thorn structure effectively changes the mechanical characteristics of pile shaft resistance softening. Due to the unique characteristic of the divergent conical surface, the truncated conical thorns exert a powerful radial pressure on the surrounding soil under load, thereby increasing the effective stress of the soil around the pile, expanding the influence range of the soil around the pile, and fully mobilizing the shear resistance of the soil, thus improving the bearing capacity of the foundation pile. The optimal shape of the taper thorn is a cone under the same conditions of length and volume. The research results can provide a theoretical foundation for the design and construction of the thorn pile.
When using pile composite foundation reinforcement for embankments in soft foundation sections, the embankment is prone to differential settlement, sliding, and even collapse. Based on the failure characteristics of pile composite foundation, this article proposes a reinforcement scheme using 'inclined-straight double-row piles' at the toe of the embankment slope. Through model tests, the deformation process, bending moment, and horizontal displacement of the pile body under lateral loading were compared for multiple sets of 'inclined-straight double-row piles'. Combined with numerical simulation analysis, the load-deformation characteristics and failure modes of the inclined-straight double-row piles under lateral loading were revealed, and a calculation analysis model was proposed to provide reference for the practical engineering application. The following conclusions were mainly drawn: (1) Under lateral loading, the inclined-straight double-row piles experience horizontal displacement, followed by bending deformation, with the inner piles failing first and the outer piles failing later, showing correlation. The failure load of the double straight piles falls between the inner and outer piles of the inclined-straight double-row piles. Increasing the bending stiffness of the inner piles and the inclination of the outer piles will significantly improve the overall stability. (2) When subjected to lateral loading, the inclined-straight double-row piles may experience overturning failure due to excessive lateral movement of the pile body or fracture failure due to excessive load on the pile body. (3) Calculation analysis models were developed for the overturning failure mode and pile body fracture failure mode.