Edward Michael Barrett

Dr. Edward Michael Barrett

orcid

Research Focus & Metrics

Representative Publications

View All Publications
15 January 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Nishesh JainNishesh Jain
Nishesh Jain
EBEsfand Burman
Esfand Burman
SSSamuel Stamp
Samuel Stamp
CSClive Shrubsole
Clive Shrubsole
RBRoderic Bunn
Roderic Bunn
MDMichael Davies
Michael Davies
Hospitals are controlled yet complex ecosystems which provide a therapeutic environment that promotes healing, wellbeing and work efficiency for patients and staff. As these buildings accommodate the sick and vulnerable, occupant wellbeing and good indoor environmental quality (IEQ) that deals with indoor air quality (IAQ), thermal comfort, lighting and acoustics are important objectives. As the specialist nature of hospital function demands highly controlled indoor environments, this makes them energy intensive buildings due to the complex and varying specifications for their functions and operations. This paper reports on a holistic building performance evaluation covering aspects of indoor air quality, thermal comfort, lighting, acoustics, and energy use. It assesses the performance issues and inter-relationships between IEQ and energy in a new building on a hospital campus in the city of Bristol, United Kingdom. The empirical evidence collated from this case study and the feedback received from the hospital staff help identify the endemic issues and constraints related to hospital buildings, such as the need for robust ventilation strategies in hospitals in urban areas that mitigate the effect of indoor and outdoor air pollution and ensuring the use of planned new low-carbon technologies. Whilst the existing guidelines for building design provide useful instructions for the protection of hospital buildings against ingress of particulate matter from outdoors, more advanced filtration strategies may be required to enact chemical reactions required to control the concentration levels of pollutants such as nitrogen dioxide and benzene. Further lessons for improved performance in operation and maintenance of hospitals are highlighted. These include ensuring that the increasingly available metering and monitoring data in new buildings, through building management systems, is used for efficient and optimal building operations for better IEQ and energy management. Overall, the study highlights the need for an integrated and holistic approach to building performance to ensure that healthy environments are provided while energy efficiency targets are met.

5 February 2025 in Journal of the Intensive Care Society
Verified
Journal Article
Open access
SWSampath Weerakkody
Sampath Weerakkody
JTJemima Unwin Teji
Jemima Unwin Teji
EBEdward Michael Barrett
Edward Michael Barrett
MKMargarita Kousteni
Margarita Kousteni
LFLorna Flores-Villa
Lorna Flores-Villa
HMHugh Montgomery
Hugh Montgomery
Background: The lighting environment in intensive care units (ICUs) is markedly different from natural light, potentially disrupting patients’ circadian rhythms and impacting staff wellbeing. New lighting technologies may mitigate these effects. Methods: A mixed methods service evaluation was conducted in a London ICU using Dyson Lightcycle™ luminaires (DLs) to evaluate staff wellbeing. Wellbeing assessments and user perceptions of the built environment were conducted using validated questionnaires before, during, and after DL deployment. Existing ambient light usage was measured using HOBO devices installed on the ceiling. Additionally, data on DL usage (including spectral data) were collected continuously using Raspberry Pi™ sensors. Results: DL usage was high (>70% per 24 h), primarily as supplementary lighting. Users found DLs easy to control and beneficial for clinical and administrative tasks. Participants assigned a 12.5% higher satisfaction score rated from 0 to 8 of lighting overall during deployment compared to pre-deployment (6.06 ± 0.29 and 5.06 ± 0.60, respectively; p = 0.20). Control variables for the built environment (noise, temperature and air quality) remained unchanged. Staff reported improvements in mood (38%, p < 0.001), fatigue (17.7%, p < 0.001), and sleep quality (21.2%, p = 0.01) during DL use. Discussion: In the first pilot feasibility service evaluation of its kind, the relationship between ICU lighting quality and staff wellbeing was investigated using DLs. We show that it is feasible to equip an ICU with a novel mode of lighting to evaluate both illuminance and user-centred outcomes. The study suggests a positive association between DL use and staff wellbeing, with notable improvements in mood, fatigue and sleep quality. The nature of the emitted light may enhance the space rather than simply illuminate, thus further adding to a feeling of wellbeing. These findings support data from studies which report effects of light brightness and colour on mood. Additionally, there appears to be a signal towards benefit to the user when additional lighting is provided, compared to the current overhead fluorescent luminaires prevalent in most ICUs. In this service evaluation these benefits were demonstrated in ICU staff operating the device. However, it is conceivable that effects such as improved mood and reduced sleep disturbance may have patient benefits too. Conclusion: Local lighting systems like DLs show promise in enhancing ICU staff wellbeing. Their impact on patient outcomes and the potential for broader implementation deserve further investigation in appropriately designed and powered larger-scale trials.


1 January 2005
Verified
Conference Paper
Closed access
PDF file
EBEdward Michael Barrett
Edward Michael Barrett
XWXuhua Wang
Xuhua Wang
PSPaul N. Stavrinou
Paul N. Stavrinou
DBDonal D. C. Bradley
Donal D. C. Bradley
Organic photodetectors made from regioregular poly(3-hexylthiophene) [P3HT] and [6,6]-phenyl C61 butyric-acid methyl-ester [PCBM] with a broad internal quantum efficiency spectrum reaching 45% at 510 nm have been shown to have a bandwidth of 500Khz that changes with device geometry.

16 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MKMandana Sarey Khanie
Mandana Sarey Khanie
ALAlessandra Luna-Navarro
Alessandra Luna-Navarro
PLPedro Pablo de la Barra Luegmayer
Pedro Pablo de la Barra Luegmayer
PMPablo Martinez-Alcaraz
Pablo Martinez-Alcaraz
EBEdward Michael Barrett
Edward Michael Barrett
LZLuca Zaniboni
Luca Zaniboni
Personalized Environmental Control Systems (PECS) are increasingly central to user-centered, data-driven buildings. They enable occupants to adjust indoor environmental conditions locally—without affecting others—while reducing unnecessary energy use. Although IEA EBC Annex 87 has defined PECS broadly across indoor domains, its application to the visual environment remains underdeveloped. In lighting and daylighting, PECS include individually controllable task luminaires, dimmable or spectrally tunable workstation lighting, and locally addressable shading or façade systems that modulate daylight and view.This paper extends and operationalizes the Annex 87 definition for the visual domain, explicitly addressing electric lighting and daylight-responsive systems that enable personalized luminous environments. Based on this framework, a systematic review of 46 peer-reviewed studies examines system configurations, evaluation methods, reported benefits, and evidence gaps.More than two-thirds of studies report positive occupant-related outcomes compared to non-personalized conditions, with few non-significant findings. Benefits most commonly include improved visual comfort and satisfaction, reduced override behavior, and increased perceived control. Reported energy savings are consistent: typically 10–40% in simulations and 10–50% in laboratory or field studies, particularly for office-based electric-lighting systems. In contrast, personalized façade and daylighting systems remain underexplored and methodologically diverse.Overall, evidence is strongest for electric-lighting PECS in office settings, while integrated lighting and daylight personalization shows moderate technology readiness. To enhance methodological consistency, this review proposes a minimum reporting checklist addressing control design, user interaction, context, participant characteristics, and visual and non-visual outcomes, supporting broader adoption of adaptive, health-oriented, low-carbon lighting strategies.

1 November 2025
Verified
Conference Paper
Closed access
Ezgi ErturkEzgi Erturk
Ezgi Erturk
CTConstantin-Cosmin Ticleanu
Constantin-Cosmin Ticleanu
EBEdward Michael Barrett
Edward Michael Barrett
PRPeter Raynham
Peter Raynham
JTJemima Unwin Teji
Jemima Unwin Teji
This study investigates criminal behaviour in London after dark by using Metropolitan Police Services (MPS) crime records from 2013 to 2019 and calculating solar altitude at the time the crime took place. The data was filtered to identify crimes where the time was known to have taken place in a window of 5 minutes or less, and only these were analysed in the study. “Darkness” is defined in this study as the condition when the solar altitude is less than –6 degrees. Findings indicate that robbery and theft from the person increased significantly after dark (p0.0001). The percentage of theft that takes place after dark, increases in Central London, compared to the whole of London. Further analysis found that robbery and theft occurrences have a significant correlation with darkness.