Jiangbo Peng

Jiangbo Peng


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
ZYZhen Yang
Zhen Yang
XYXin Yu
Xin Yu
JPJiangbo Peng
Jiangbo Peng
LWLiyuan Wang
Liyuan Wang
ZDZhiwei Dong
Zhiwei Dong
HXHuanhuan Xu
Huanhuan Xu

31 October 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Hao DongHao Dong
Hao Dong
SLShicheng Liu
Shicheng Liu
LYLiming Yang
Liming Yang
JPJiangbo Peng
Jiangbo Peng
KCKeming Cheng
Keming Cheng
An optical fiber displacement sensor based on the microwave photonics interferometric (MWPI) method is proposed and experimented, which provides an ideal solution for large range displacement measurement with high resolution. The sensor used a Michelson microwave photonics interferometer to sense the displacement with one sensing arm and a length-adjusted reference arm. The displacement variation would change the period of the microwave response function of the interferometer. According to the principle that the phase difference in one free spectral range (FSR) of the microwave response function is 360°, the displacement can be retrieved by the microwave response function by means of a vector network analyzer (VNA). A programmable path-switching true time delay line was used in the reference arm to decrease the microwave bandwidth. The measurement results show that the displacement sensing range is larger than 3 m and the measurement resolution is 31 μm. Finally, the measurement stability is tested, and the factors affecting the measurement resolution of this method and the main source of errors are investigated in detail.

28 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
Yufei MaYufei Ma
Yufei Ma
YHYing He
Ying He
CCCheng Chen
Cheng Chen
XYXin Yu
Xin Yu
JZJingbo Zhang
Jingbo Zhang
Frank TittelFrank Tittel
Frank Tittel
A novel quartz enhanced photoacoustic spectroscopy (QEPAS) trace gas detection scheme is reported in this paper. A cylindrical lens was employed for near-infrared laser focusing. The laser beam was shaped as a planar line laser between the gap of the quartz tuning fork (QTF) prongs. Compared with a spherical lens-based QEPAS sensor, the cylindrical lens-based QEPAS sensor has the advantages of easier laser beam alignment and a reduction of stringent stability requirements. Therefore, the reported approach is useful in long-term and continuous sensor operation.

13 May 2011 in Optics Letters
Verified
Journal Article
Closed access
PDF file
XYXin Yu
Xin Yu
JPJiangbo Peng
Jiangbo Peng
RSRui Sun
Rui Sun
YYYachao Yi
Yachao Yi
PYPeng Yang
Peng Yang
DCDeying Chen
Deying Chen
We first research the effects of femtosecond-laser-induced plasma (FLIP) on a laminar premixed methane/oxygen/nitrogen flame speed with a wide range of equivalence ratios (0.8–2.0) at atmospheric pressure. It is experimentally found that the flame speed increases by 30.8% at equivalence ratio 1.33, and the effects of the FLIP on the flame speed are more remarkable when the methane is rich. The self-emission spectra from the flame and the plasma are studied, and the presence of the oxygen atom is likely to be a key factor in enhancing flame speed.

4 December 2019 in Frontiers in Physics
Verified
Journal Article
Open access
PDF file
XYXin Yu
Xin Yu
GCGuang Chang
Guang Chang
JPJiangbo Peng
Jiangbo Peng
HDHao Dong
Hao Dong
YYYang Yu
Yang Yu
TQTianjiao Qu
Tianjiao Qu
Planar laser-induced fluorescence (PLIF) of toluene and acetone is performed for visualization of spatial distribution of oxygen in gas and oxygen mixing region in the nozzle flow field. The principle of the calibration methods of oxygen concentration distribution is expounded in this paper. As the two tracers had different situations on oxygen quenching effect, the ratio of the fluorescence images of the two tracers could be used to measure the oxygen concentration in the mixed area. In this way, the ratio of fluorescence signal intensity of toluene to acetone was found to be linearly related to oxygen concentration. By using this calibration relationship, we can measure the oxygen concentration distribution of the nozzle flow field with an accuracy of 12.6%. It indicates that this measurement method can be applied in a turbulent flow field. The variation trend of oxygen concentration distribution in the nozzle flow field can be analyzed by capturing multiple PLIF images in time sequence, which has the important reference value for the development of the nozzle burner flame.

1 June 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
XYXin Yu
Xin Yu
JPJiangbo Peng
Jiangbo Peng
RSRui Sun
Rui Sun
XYXiaochuan Yang
Xiaochuan Yang
CWChunhong Wang
Chunhong Wang
DCDeying Chen
Deying Chen
The influence of femtosecond laser-induced plasma (FLIP) on the stability of a premixed CH4/O2/N2 flame is investigated at atmospheric pressure. The laser energy, laser repetition rate, the equivalence ratios, and the volume percentage of oxygen in O2/N2 blends are varied. Our findings indicate that the flame blow-off velocity is a function of these parameters. It has been experimentally found that the flame blow-off velocity increases by a factor of two with FLIP than without FLIP. A high-repetition-rate and a great energy laser-induced plasma flameholding, as a non-intrusive optical flameholding, may be a feasible alternative for any combustor.