Safety and crime prevention are significant concerns in both urban and rural areas. Crime Prevention Through Environmental Design (CPTED) guidelines provide an architectural strategy to deter criminal activities by implementing strategic design plans, particularly through effective lighting schemes in urban settings. These measures aim to reduce the fear of crime and enhance the overall quality of life. Enhanced street lighting plays a crucial role in environmental crime prevention by lowering both actual crime rates and the perceived risk of criminal activity in built environments. Current recommendations emphasize installing lighting in poorly lit areas for safety; however, assessing road surface luminance solely based on existing streetlights is insufficient. The research underscores that well-illuminated streets with uniform lighting and higher illuminance levels enhance pedestrian safety and comfort. In addition, this study proposes standardized illumination levels specifically for outdoor facial recognition to aid in identifying potential offenders. It outlines the critical vertical illuminance range and Color Rendering Index (CRI) values necessary for this purpose. Furthermore, metrics like the Brightness Index and Safety Index were developed to enhance night-time security and illustrate their correlation with crime rates. Ultimately, this research introduces quantitative lighting standards to enhance the effectiveness of CPTED guidelines, contributing to efforts to reduce crime incidence.
15 May 2017 in Journal of Asian Architecture and Building Engineering
Efficient control of ventilation and cooling/heating systems in buildings is integral to making adjustments to indoor environments and to minimizing energy use. In high-rise buildings, however, the stack effect is generated through vertical shafts in the buildings, and the air flow due to the stack effect greatly affects the efficiency of airconditioning systems used for ventilation, cooling, and heating. Therefore, attenuating the stack effect in high-rise buildings is a critical aspect of HVAC operations as well as a solution for direct problems related to the stack effect, such as high-velocity draft, high-level noise in the buildings, and so on. In general, as a method to attenuate the stack effect in high-rise buildings, revolving doors are installed at the lobby entrance. However, while this method may be effective on the floors where revolving doors are applied, the efficiency is very low when considering the entire building due to the existence of many air flow paths and the fact that revolving doors applied to only part of a building can control only a portion of the air flow. Numerical simulation analysis was performed in this study to quantitatively examine the stack effect attenuation characteristics of revolving doors on both a partial building level and for the entire building. In addition, the effects of building height and airtightness on the performance of the building envelope were considered.
1 May 2017 in Journal of Asian Architecture and Building Engineering
The South Korean and Seoul metropolitan governments have been forced to radically change the current High Pressure Sodium (HPS) lamps to Light Emitting Diode (LED) lamps for street lighting in cities according to "LED Plan 2060." Thus, this study aims to evaluate the feasibility of LED-based street lighting by analyzing energy efficiency and life cycle cost. For this purpose, a comparison of the lighting energy consumption by dimming control in Wooi Stream as a test bed project was conducted and the life cycle cost of LED lamps for replacing HPS lamps for street lighting was analyzed. As a result, LED lamp replacement could reduce the energy consumption by 69% compared to HPS lamps, and the dimming control system by pedestrian movements could save 77% of lighting energy. However, the payback period of LED replacement is 11.5 years. This indicates that the high purchase price of LED lamps would decline by 80% within 4-5 years with assertive investment for commercializing LED lamps and rapid growth of the lighting market in Korea, if LED lamps in street lighting have an economic performance.
In a conventional daylight-responsive dimming system (DRDS), all the luminaires are turned off during the calibration process except for the luminaire under consideration in order to sense only the workplane illuminance of that luminaire. However, the workplane illuminance of the luminaire is influenced by other luminaires. Therefore, the final workplane illuminance of the actual operated system is higher than the target workplane illuminance, reducing the energy-saving efficiency of the DRDS. Herein, to improve the conventional DRDS, an advanced commissioning prediction method of daylight illuminance, and a dimming control algorithm considering the influences by distant luminaires are proposed. To evaluate the accuracy of the proposed prediction method of daylight illuminance, the daylight illuminance on the workplane and the photo sensor values of six points were measured in a full-scale mockup for 27 consecutive days from 22 June to 18 July 2018. As a result of root-mean-square error (RMSE) analysis of daylight illuminance and the photo sensor values, the RMSE (64.86) of P3 located in the middle of the room was the highest, and the RMSE value (17.60) of P5 located near the window was the lowest. In addition, the power consumption of the luminaires, and the target illuminance accuracy of the proposed DRDS were measured and analyzed for 32 consecutive days from 19 July to 19 August 2018 in a full-scale mockup. The average target illuminance accuracy was 96.9% (SD 2.2%), the average lighting energy-savings ratio was 78.4%, and the daylight illuminance prediction accuracy was 95.5% (SD 3.4%).
Safety and the apprehension of crime persist as significant concerns in both urban and rural locales. Crime Prevention Through Environmental Design (CPTED) guidelines, an architectural approach to crime deterrence, mitigate the likelihood of criminal activity by implementing strategic defensive design plans, particularly through effective lighting schemes within urban settings, thereby alleviating fear of crime. This comprehensive set of principles serves to enhance overall quality of life. Additionally, within the realm of environmental crime prevention, enhanced street lighting has been identified as a crucial factor in diminishing both actual crime rates and the perceived risk of criminal activity in built environments. While current recommendations advocate for the installation of lighting in poorly lit areas for safety reasons, evaluating visibility solely based on the presence of existing streetlights proves insufficient for analyzing road surface luminance comprehensively. Thus, this study proposes establishing standardized illumination levels specifically tailored for facial recognition of potential criminal offenders. Furthermore, we advocate for defining specific thresholds for color temperature and colorimetric criteria to aid in distinguishing characteristics of individuals' attire. To analyze photometric safety and crime frequency in Seoul, Korea, new primary evaluation indicators were developed, including the Brightness index, Informatization index, and Safety index. By incorporating quantitative data into lighting design strategies, particularly within the framework of CPTED, there exists the potential to mitigate fear of crime during nighttime hours. These strategies facilitate the creation of well-lit environments conducive to the swift recognition and identification of potential perpetrators, thereby presenting a proactive approach to crime prevention. Consequently, this study introduces quantitative lighting standards to augment the efficacy of CPTED guidelines, ultimately contributing to the reduction of crime incidence.
This study aims to evaluate the accuracy and energy savings of a daylight responsive dimming system (DRDS) when considering the influence of indirect illuminance. In the case of the existing DRDS, during the calibration process of each luminaire, the other luminaires were turned off to detect the illuminance of both the luminaire and the incoming daylight. However, the work plane illuminance under the luminaires was affected by the indirect illuminance from the other luminaires. The final work plane illuminance would thus be higher than the target illuminance during real system operation. To improve the accuracy and energy savings of the DRDS, an improved dimming control algorithm was applied to the DRDS when considering the influence of indirect illuminance. The real-time power consumption and accuracy of the target illuminance of the DRDS when considering the influence of indirect illuminance in a full-scale mock-up was measured and analyzed (for 23 days, from 22 June to 18 July 2018). As a result, the average accuracy of the target illuminance was 98.9% (SD 0.5%), and the average saving in lighting energy was 77%.