Beomseok Go

Dr. Beomseok Go


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2017 in Journal of Asian Architecture and Building Engineering
Verified
Journal Article
Open access
PDF file
JLJoonghoon Lee
Joonghoon Lee
BGBeomseok Go
Beomseok Go
THTaeyon Hwang
Taeyon Hwang
Efficient control of ventilation and cooling/heating systems in buildings is integral to making adjustments to indoor environments and to minimizing energy use. In high-rise buildings, however, the stack effect is generated through vertical shafts in the buildings, and the air flow due to the stack effect greatly affects the efficiency of airconditioning systems used for ventilation, cooling, and heating. Therefore, attenuating the stack effect in high-rise buildings is a critical aspect of HVAC operations as well as a solution for direct problems related to the stack effect, such as high-velocity draft, high-level noise in the buildings, and so on. In general, as a method to attenuate the stack effect in high-rise buildings, revolving doors are installed at the lobby entrance. However, while this method may be effective on the floors where revolving doors are applied, the efficiency is very low when considering the entire building due to the existence of many air flow paths and the fact that revolving doors applied to only part of a building can control only a portion of the air flow. Numerical simulation analysis was performed in this study to quantitatively examine the stack effect attenuation characteristics of revolving doors on both a partial building level and for the entire building. In addition, the effects of building height and airtightness on the performance of the building envelope were considered.

17 December 2025 in Buildings
Verified
Journal Article
Open access
PDF file
BGBeomseok Go
Beomseok Go
Kyunam RheeKyunam Rhee
Kyunam Rhee
JKJoowook Kim
Joowook Kim
THTaeyon Hwang
Taeyon Hwang
Achieving good daylighting while maintaining thermal comfort and reducing perimeter energy use is a key challenge in low-energy office buildings. This study developed a thermally activated light shelf (TALS) system that integrates multiple functions into a conventional light shelf. The top surface blocks excessive perimeter light and reflects daylight deeper into the room, while the bottom surface operates as a radiant heating and cooling panel using circulating warm or cool water. To evaluate the system, full-scale empirical experiments were conducted in a mock-up test bed with two identical office-like cells under the same boundary conditions; one cell was equipped with TALS and the other served as a reference. Indoor thermal environment indices and heating and cooling energy use were monitored during winter and summer. The TALS room achieved ISO 7730 Category A comfort more frequently, with Category A cumulative duration approximately 3.4 times longer in winter and 7.8 times longer in summer compared with the non-TALS room. In addition, heating and cooling energy were reduced by about 39.2% and 7.7%, respectively. These promising results are based on a single prototype and climate, and further studies are needed to optimize TALS capacity and window-related heat loss.

1 September 2017 in Journal of Asian Architecture and Building Engineering
Verified
Journal Article
Closed access
THTaeyon Hwang
Taeyon Hwang
BGBeomseok Go
Beomseok Go