Dimitre Hristov

Dr. Dimitre Hristov


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2020 in Medical Physics
Verified
Journal Article
Closed access
PDF file
XLXiaokun Liang
Xiaokun Liang
WZWei Zhao
Wei Zhao
DHDimitre Hristov
Dimitre Hristov
MBMark K. Buyyounouski
Mark K. Buyyounouski
SHSteven L. Hancock
Steven L. Hancock
LXLei Xing
Lei Xing

1 March 2017 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
AKAhmed El Kaffas
Ahmed El Kaffas
KSKevin Smith
Kevin Smith
PPPooja Pradhan
Pooja Pradhan
SMSteven Machtaler
Steven Machtaler
HWHuaijun Wang
Huaijun Wang
DHDimitre Hristov
Dimitre Hristov

19 October 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ESEmil Schüler
Emil Schüler
RMRichard Mallozzi
Richard Mallozzi
JLJoshua Levy
Joshua Levy
DHDimitre Hristov
Dimitre Hristov
Comprehensive characterization of geometric distortions for MRI simulators and MRI‐guided treatment delivery systems is typically performed with large phantoms that are costly and unwieldy to handle. Here we propose an easily implementable methodology for MR distortion determination of the entire imaging space of the scanner through the use of a compact commercially available distortion phantom. The MagphanRT phantom was scanned at several locations within a MR scanner. From each scan, an approximate location of the phantom was determined from a subset of the fiducial spheres. The fiducial displacements were determined, and a displacement field was fitted to the displacement data using the entire multi‐scan data set. An orthogonal polynomial expansion fitting function was used that had been augmented to include independent rigid‐body transformations for each scan. The rigid‐body portions of the displacement field were thereafter discarded, and the resultant fit then represented the distortion field. Multi‐positional scans of the phantom were used successfully to determine the distortion field with extended coverage. A single scan of the phantom covered 20 cm in its smallest dimension. By stitching together overlapping scans we extended the distortion measurements to 30 cm. No information about the absolute location or orientation of each scan was required. The method, termed the Multi‐Scan Expansion (MSE) method, can be easily applied for larger field‐of‐views (FOVs) by using a combination of larger phantom displacements and more scans. The implementation of the MSE method allows for distortion determination beyond the physical limitations of the phantom. The method is scalable to the user’s needs and does not require any specialized equipment. This approach could open up for easier determination of the distortion magnitude at distances further from the scanner’s isocenter. This is especially important in the newly proposed methodologies of MR‐only simulation in RT and in adaptive replanning in MR linac systems.

17 December 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
XLXiaokun Liang
Xiaokun Liang
MBMaxime Bassenne
Maxime Bassenne
DHDimitre Hristov
Dimitre Hristov
TITauhidul Islam
Tauhidul Islam
WZWei Zhao
Wei Zhao
Lei XingLei Xing
Lei Xing

26 August 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
SMSTAVROS MELEMENIDIS
STAVROS MELEMENIDIS
AKAnna Stephanie Kim
Anna Stephanie Kim
JVJenny M. Vo-Phamhi
Jenny M. Vo-Phamhi
Edward Elliot GravesEdward Elliot Graves
Edward Elliot Graves
AKAhmed El Kaffas
Ahmed El Kaffas
DHDimitre Hristov
Dimitre Hristov
We report a low-cost protocol and platform for whole-abdomen 3D dynamic contrast-enhanced ultrasound (DCE-US) imaging in mice using a clinical matrix-array transducer. Background/Objectives: This platform addresses common limitations of preclinical ultrasound systems. In particular, these systems often lack real-time volumetric and molecular imaging capabilities. Methods: Using a modified silicone cup and water bath configuration, mice with dual subcutaneous tumors were imaged in vivo on a clinical EPIQ 7 system equipped with an X6-1 transducer. Results: Intravenous administration of targeted microbubbles enabled high-resolution, contrast-mode 3D imaging at multiple time points. Volumetric reconstructions captured both tumors and surrounding anatomy in a single scan, while time–intensity curves and Differential Targeted Enhancement (DTE) analysis revealed greater microbubble uptake in irradiated tumors, consistent with elevated P-selectin expression. Conclusions: This standardized imaging platform enables whole-abdomen molecular DCE-US in preclinical studies, facilitating intra-animal comparisons of vascular and molecular features across lesions or organs.

12 December 2024 in arXiv
Verified
Preprint
Open access
PDF file
SMStavros Melemenidis
Stavros Melemenidis
AKAnna Stephanie Kim
Anna Stephanie Kim
JVJenny Vo-Phamhi
Jenny Vo-Phamhi
EGEdward Graves
Edward Graves
AKAhmed El Kaffas
Ahmed El Kaffas
DHDimitre Hristov
Dimitre Hristov
Background: This protocol introduces an ultrasound (US) configuration for whole-body 3D dynamic contrast-enhanced ultrasound (DCE-US) imaging in preclinical applications. The set-up relies on a clinical abdominal matrix US probe to enable mice imaging beyond current preclinical systems that are generally unable to capture whole-body volumetric and dynamic imaging. We demonstrate via this protocol the feasibility of volumetric contrast-enhanced and molecular 3D imaging in the entire lower body of mouse, as well as the capability of imaging multiple lesions in the same animal simultaneously with a single contrast bolus injection. Methods: We modified a silicone cup with a 101.6 mm inner diameter and 6.4 mm wall thickness, to a height of 76.2 mm and cut out a rectangular side window (12.7 mm x 15.9 mm) at the lower part of the cup. Mice were positioned with their head and the two front legs outside of the cup while the rest of the body remained inside the cup and submerged under water; the edges around the mouse's body in contact with the cup's wall were sealed with Vaseline to prevent water leakage, and the cup was filled with warm water to maintain the mouse's body heat. Imaging was conducted using a portable clinical ultrasound system (EPIQ 7 Philips) with an abdominal matrix-array transducer (PM mode, X6-1) inserted into the top of the cup, and positioned to visualize the entire of the mouse's abdomen. The mice were imaged before and after the injection of P-selectin-targeted microbubbles. Results: Here, in nude mice with two adjacent tumors, we demonstrate that a commercially available clinical matrix transducer can be utilized to achieve whole-body 3D DCE-US and molecular US imaging, as well as capture independent qualitative and quantitative information from several lesions or organs at different locations in the animal, through a single bolus injection.