Recent developments in humidity sensors have heightened the need for reliability. Seeing as many products such as humidity sensors experience multiple dependent competing failure processes (MDCFPs) with self-recovery, this paper proposes a new general reliability model. Previous research into MDCFPs has primarily focused on the processes of degradation and random shocks, which are appropriate for most products. However, the existing reliability models for MDCFPs cannot fully characterize the failure processes of products such as humidity sensors with significant self-recovery, leading to an underestimation of reliability. In this paper, the effect of self-recovery on degradation was analyzed using a conditional probability. A reliability model for soft failure with self-recovery was obtained. Then, combined with the model of hard failure due to random shocks, a general reliability model with self-recovery was established. Finally, reliability tests of the humidity sensors were presented to verify the proposed reliability model. Reliability modeling for products subject to MDCFPs with considering self-recovery can provide a better understanding of the mechanism of failure and offer an alternative method to predict the reliability of products.
The smart electricity meter (SEM) is an important part of smart power grid, and the accuracy of SEMs is the basis for power grid operation control and trade settlement between power supply and electricity consumption, but the evolution behaviors of metering error of SEMs under field operation conditions have not yet been identified. The SEMs were installed and operated on site, metering error data were collected under various temperature and current conditions. The influences of current, power coefficient, and temperature on metering error and consistency were analyzed separately with the help of quadratic polynomials, and then an integrated model elaborating the joint effects of multi-stress was developed based on a binary quadratic polynomial. We find that a lower temperature and a larger current result in a higher metering error of SEMs; however, the effects of current on metering error are determined by power coefficients. The results have reference value for remote metrological verification, error monitoring, and the optimization of the operation and maintenance scheme of SEMs.
With the increase of the penetration rate of renewable energy power generation in the power system, the power grid gradually tends to be weak. Under the scenario of nonlinear load connecting to weak power grid, the grid-side voltage will produce unbalance, distortion and frequency deviation due to the influence of large internal impedance, insufficient inertia, three-phase current unbalance and harmonics of weak power grid. The operation of active power filters (APF) under above conditions can lead to significant degradation in harmonic compensation performance. An adaptive proportional integral (PI) + vector PI (VPI) harmonic compensation strategy for a three-phase APF is proposed for use in complex conditions of weak grid. The strategy consists of an adaptive notch filter based synchronous phase-locked loop (ANF-PLL) and an adaptive PI + VPI current control method. In this strategy, a series of adaptive lattice notch filters are introduced to improve the accuracy of grid phase and frequency estimation under the condition of voltage unbalance, distortion and a large range of frequency deviation. Then the phase and frequency information are used in the Park transformation of harmonic detection and current compensation control and the update of PI + VPI current control law parameters. A VPI current tracking controller with adaptive resonant frequency is constructed, which can improve the gain of the resonant frequency point and ensure that the APF can maintain the best compensation performance under the above weak grid conditions. Finally, the simulation and experimental results indicate that the ANF-PLL shows a better phase and frequency estimation performance under complex conditions of weak grid than the conventional and notch filter based methods, and the harmonic compensation strategy presented in this paper achieves a significant performance improvement under complex conditions of weak grid compared with Fixed VPI/SRF-PLL strategy and adaptive VPI/NF-PLL strategy.
The performance and reliability of lithium thionyl chloride (Li/SOCl2) batteries are significantly affected by temperature, but the reliability level and failure mechanisms of Li/SOCl2 batteries remain unclear. In this study, Weibull distribution statistics were used to infer the life expectancy of Li/SOCl2 batteries at different temperatures. Additionally, the battery failure mechanism was analyzed using electrochemical impedance spectroscopy (EIS). It is found that under the discharge condition of 7.5 kΩ load, the mean time between failures (MTBF) and reliable life of the battery decreased with increasing operating temperature. Under the discharge condition of 750 Ω load, the MTBF of the battery peaked at 60 °C. Furthermore, the influence of temperature on the voltage output characteristics of Li/SOCl2 batteries and the voltage hysteresis were analyzed. Both the battery output voltage and the hysteresis effect increased with rising temperature. This is because high temperature accelerates internal battery reactions, thus altering the formation process of the passivation film on the lithium metal negative electrode.
The deposition of micron particles in gas pipelines has always been an important problem in ultra-clean ventilation technology in the modern laser fusion, precision electronics, aerospace, and biomedical fields. Combining the mathematical expression of the migration, collision, and deposition of micron particles in a gas pipeline with a simulation of flow fields, a two-parameter particle probability deposition model based on , and collision probability coefficient is established, and the distribution law of particle deposition, considering two deposition targets of the pipe wall and deposition layer, is given. Combined with an experiment on particle migration and deposition in a gas pipeline, an interpretation and verification of the particle deposition distribution law are given, and the difference between the model and experiment is discussed through particle deposition efficiency mass distribution. Studies have shown the following: Under the premise of two kinds of deposition targets, different particle sizes in the gas pipeline present different deposition laws; the deposit morphology is a spot deposit of 10 µm particles and a flake deposit of 40 µm particles; the deposit position shows a uniform distribution and a lower wall dominance; and the deposit concentration area of 40 µm shows a more significant distribution. The results are very important for the selection and optimization of gas pipelines for clean spaces.