Zuzana Orságová Králová

Dr. Zuzana Orságová Králová

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2013 in Journal of Porous Materials
Verified
Journal Article
Closed access
PDF file
AOAndrej Oriňák
Andrej Oriňák
Renata OrinakovaRenata Orinakova
Renata Orinakova
ZKZuzana Orságová Králová
Zuzana Orságová Králová
ATAndrea Morovska Turonova
Andrea Morovska Turonova
MKMiriam Kupková
Miriam Kupková
Róbert DžundaRóbert Džunda
Róbert Džunda

28 June 2018 in Metals
Verified
Journal Article
Open access
PDF file
LHLucia Haverová
Lucia Haverová
Renata OrinakovaRenata Orinakova
Renata Orinakova
AOAndrej Orinak
Andrej Orinak
RGRadka Gorejová
Radka Gorejová
Matej BalážMatej Baláž
Matej Baláž
ATAndrea Morovska Turonova
Andrea Morovska Turonova
Iron-based substrates with polyethylene glycol coating were prepared as possible materials for biodegradable orthopedic implants. Biodegradable materials that provide mechanical support of the diseased tissue at the time of implanting and then disappear gradually during the healing process are sometimes favored instead of permanent implants. The implant degradation rate should match the time of the tissue regrowth. In this work, the degradation behavior of iron-based foams was studied electrochemically during immersion tests in Hanks’ solution. The corrosion rate of the polyethylene glycol-coated samples increased and the corrosion potential shifted to more negative values. This indicates an enhanced degradation rate as compared to the uncoated material, fulfilling the goal of being able to tune the degradation rate. It is the interfacial interaction between the hydrophilic polymer layer and the iron surface that is responsible for the enhanced oxidation rate of iron.

2 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
RGRadka Gorejová
Radka Gorejová
Renata OrinakovaRenata Orinakova
Renata Orinakova
ZKZuzana Orságová Králová
Zuzana Orságová Králová
Matej BalážMatej Baláž
Matej Baláž
MKMiriam Kupkova
Miriam Kupkova
KKKarol Kovaľ
Karol Kovaľ
Research in the field of biodegradable metallic scaffolds has advanced during the last decades. Resorbable implants based on iron have become an attractive alternative to the temporary devices made of inert metals. Overcoming an insufficient corrosion rate of pure iron, though, still remains a problem. In our work, we have prepared iron foams and coated them with three different concentrations of polyethyleneimine (PEI) to increase their corrosion rates. Scanning electron microscopy (SEM) coupled with energy dispersive X-ray analysis (EDX), Fourier-transform infrared spectroscopy (FT-IR), and Raman spectroscopy were used for characterization of the polymer coating. The corrosion behavior of the powder-metallurgically prepared samples was evaluated electrochemically using an anodic polarization method. A 12 weeks long in vitro degradation study in Hanks’ solution at 37 °C was also performed. Surface morphology, corrosion behavior, and degradation rates of the open-cell foams were studied and discussed. The use of PEI coating led to an increase in the corrosion rates of the cellular material. The sample with the highest concentration of PEI film showed the most rapid corrosion in the environment of simulated body fluids.

15 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Radovan HudákRadovan Hudák
Radovan Hudák
MSMarek Schnitzer
Marek Schnitzer
ZKZuzana Orságová Králová
Zuzana Orságová Králová
RGRadka Gorejová
Radka Gorejová
LMLukáš Mitrík
Lukáš Mitrík
JZJozef Zivcak
Jozef Zivcak
This work is devoted to the research of porous titanium alloy structures suitable for use in biomedical applications. Mechanical properties were examined on six series of samples with different structures and porosity via static compressive test to identify the type of structure suitable for elimination of the “stress shielding” effect. In addition, high porosity is desirable due to the overgrowth of bone tissue into the internal structure of the implant. The samples were made of titanium alloy Ti6Al4V by using selective laser melting (SLM) additive manufacturing. The series of samples differ from each other in pore size (200, 400, and 600 µm) and porous structure topology (cubic or trabecular). The actual weight of all samples, which plays an important role in identifying other characteristics, was determined. Compressive tests were focused on the detection of maximum stress. The highest porosity and thus the lowest weight were achieved in the samples with a trabecular structure and 600 µm pore size. All tested samples reached optimal values of maximum stress and tensile strength. The most appropriate mechanical properties were observed for samples with a 200 µm pore diameter and cubic structure.

24 August 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Renata OrinakovaRenata Orinakova
Renata Orinakova
RGRadka Gorejová
Radka Gorejová
ZKZuzana Orságová Králová
Zuzana Orságová Králová
AOAndrej Orinak
Andrej Orinak
Significant progress was achieved presently in the development of metallic foam-like materials improved by biocompatible coatings. Material properties of the iron, magnesium, zinc, and their alloys are promising for their uses in medical applications, especially for orthopedic and bone tissue purposes. Current processing technologies and a variety of modifications of the surface and composition facilitate the design of adjusted medical devices with desirable mechanical, morphological, and functional properties. This article reviews the recent progress in the design of advanced degradable metallic biomaterials perfected by different coatings: polymer, inorganic ceramic, and metallic. Appropriate coating of metallic foams could improve the biocompatibility, osteogenesis, and bone tissue-bonding properties. In this paper, a comprehensive review of different coating types used for the enhancement of one or several properties of biodegradable porous implants is given. An outline of the conventional preparation methods of metallic foams and a brief overview of different alloys for medical applications are also provided. In addition, current challenges and future research directions of processing and surface modifications of biodegradable metallic foams for medical applications are suggested.

1 April 2020 in Applied Surface Science
Verified
Journal Article
Closed access
RORenáta Oriňaková
Renáta Oriňaková
RGRadka Gorejová
Radka Gorejová
ZKZuzana Orságová Králová
Zuzana Orságová Králová
AOAndrej Oriňak
Andrej Oriňak
ISIvan Shepa
Ivan Shepa
MOMichal Oriňak
Michal Oriňak