Stijn Legtenberg

Mr. Stijn Legtenberg

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
Gijs van PraaghGijs van Praagh
Gijs van Praagh
Francine VosFrancine Vos
Francine Vos
SLStijn Legtenberg
Stijn Legtenberg
MWMarjan Wouthuyzen-Bakker
Marjan Wouthuyzen-Bakker
IKIlse Kouijzer
Ilse Kouijzer
BSBen R. Saleem
Ben R. Saleem
Objective: We evaluated the feasibility of a machine-learning (ML) model based on clinical features and radiomics from [18F]FDG PET/CT images to differentiate between infected and non-infected intracavitary vascular grafts and endografts (iVGEI). Methods: Three ML models were developed: one based on pre-treatment criteria to diagnose a vascular graft infection (“MAGIC-light features”), another using radiomics features from diagnostic [18F]FDG-PET scans, and a third combining both datasets. The training set included 92 patients (72 iVGEI-positive, 20 iVGEI-negative), and the external test set included 20 iVGEI-positive and 12 iVGEI-negative patients. The abdominal aorta and iliac arteries in the PET/CT scans were automatically segmented using SEQUOIA and TotalSegmentator and manually adjusted, extracting 96 radiomics features. The best-performing models for the MAGIC-light features and PET-radiomics features were selected from 343 unique models. Most relevant features were combined to test three final models using ROC analysis, accuracy, sensitivity, and specificity. Results: The combined model achieved the highest AUC in the test set (mean ± SD: 0.91 ± 0.02) compared with the MAGIC-light-only model (0.85 ± 0.06) and the PET-radiomics model (0.73 ± 0.03). The combined model also achieved a higher accuracy (0.91 vs. 0.82) than the diagnosis based on all the MAGIC criteria and a comparable sensitivity and specificity (0.70 and 1.00 vs. 0.76 and 0.92, respectively) while providing diagnostic information at the initial presentation. The AUC for the combined model was significantly higher than the PET-radiomics model (p = 0.02 in the bootstrap test), while other comparisons were not statistically significant. Conclusions: This study demonstrated the potential of ML models in supporting diagnostic decision making for iVGEI. A combined model using pre-treatment clinical features and PET-radiomics features showed high diagnostic performance and specificity, potentially reducing overtreatment and enhancing patient outcomes.

3 March 2026 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
SLStijn Legtenberg
Stijn Legtenberg
JMJozine M ter Maaten
Jozine M ter Maaten
MEMichiel E Erasmus
Michiel E Erasmus
MKMichiel Kuijpers
Michiel Kuijpers
YDYvonne L Douglas
Yvonne L Douglas
KDKevin Damman
Kevin Damman
Left ventricular assist device (LVAD) therapy is an established treatment modality for patients with advanced heart failure with reduced ejection fraction (HFrEF). This study aimed to evaluate the long-term outcomes of patients implanted with a Heartmate 3 LVAD. We included 176 patients who were implanted with a HeartMate 3 LVAD at the University Medical Center Groningen (UMCG) between 2016 and 2025. The primary outcome of interest was on device survival. Secondary outcomes were major adverse events (including device dysfunction, major bleeding, device-related infections, ventricular tachycardia, cerebrovascular events and heart failure hospitalizations) stratified according to LVAD treatment strategy. Mean age at implantation was 56 ± 11 years, and 26% were female. The initial device strategy was bridge to transplant (BTT) in 24%, destination therapy (DT) in 34%, and bridge to decision (BTD) in 42%. Overall survival was 87%, 82% and 61% at 1, 2 and 5 years respectively. Kaplan–Meier analysis suggested longer on-device survival in BTT compared with DT patients, although interpretation is limited by differential censoring due to transplantation. Device-related infections and heart failure hospitalizations were the most common major adverse events, occurring 0.29 and 0.18 events per patient-year at risk, respectively. Device dysfunction and cerebrovascular events were rare, with incidence rates of 0.04 and 0.02 events per patient-year at risk, respectively. No LVAD pump thrombosis events were recorded during this time period. Long-term survival on HeartMate 3 LVAD support exceeded 60% at 5 years in this single-center cohort. While adverse events such as device related infections and heart failure hospitalizations continue to pose a substantial clinical challenge, the incidence of thrombotic complications was low, underscoring improvement in clinical outcomes with current generation centrifugal LVAD devices.

21 October 2026 in JHLT Open
Verified
Journal Article
Open access
SLStijn Legtenberg
Stijn Legtenberg
JMJozine M. ter Maaten
Jozine M. ter Maaten
MEMichiel E. Erasmus
Michiel E. Erasmus
MKMichiel Kuijpers
Michiel Kuijpers
YDYvonne L. Douglas
Yvonne L. Douglas
KDKevin Damman
Kevin Damman

14 November 2026 in Heart, Lung and Circulation
Verified
Journal Article
Open access
RPRaden A.D.A. Puspitarani
Raden A.D.A. Puspitarani
SLStijn Legtenberg
Stijn Legtenberg
MEMichiel E. Erasmus
Michiel E. Erasmus
JMJozine M. ter Maaten
Jozine M. ter Maaten
JKJan A. Krikken
Jan A. Krikken
KDKevin Damman
Kevin Damman

4 September 2026 in Journal of Cardiac Failure
Verified
Journal Article
Open access
SLStijn Legtenberg
Stijn Legtenberg
KSKarine Santos
Karine Santos
IBIris E. Beldhuis
Iris E. Beldhuis
OHOliver Hartmann
Oliver Hartmann
LZLara E.E.C. Zonneveld
Lara E.E.C. Zonneveld
JMJozine Ter Maaten
Jozine Ter Maaten

22 May 2026 in European Journal of Heart Failure
Verified
Journal Article
Open access
SLStijn Legtenberg
Stijn Legtenberg
JMJozine M ter Maaten
Jozine M ter Maaten
KDKevin Damman
Kevin Damman