1 January 2023 in Journal of Engineering Sciences
Fire tests of reinforced concrete floor slabs do not allow the detection of the onset of the boundary state due to loss of entirety because blocks are installed on the unheated surface to reproduce the design load. This prevents the formation of cracks through which toxic combustion products, smoke, and temperature spread can penetrate. Determining a building structure’s actual fire resistance limit was fixed at the onset of any fire resistance boundary state. It was proven that calculation methods for fire resistance assessment have significant advantages over experimental methods. To reduce the number of finite elements for a rational calculation of the fire resistance assessment of a reinforced concrete hollow core slab, a geometric model of 1/4 of this structure was built. The possibility of visualizing the studied structure at full scale was realized when obtaining the calculation results. The stress-strain state of the studied structure was evaluated based on the thermal and mechanical loading results applied to the reinforced concrete hollow core slab. Thus, the work’s objective was achieved based on the calculation experiments’ results. A methodology was developed for calculating the destruction of a reinforced concrete hollow core slab while assessing its fire resistance. Scientific fundamentals for determining the onset of the boundary state of loss of entirety were developed. The proposed methodology allowed for a reliable assessment of the fire resistance of such structures.
29 December 2023 in Zeszyty Naukowe SGSP
The work presents the absorption rate constant of ammonia into water using a station with spiralnozzles. In the research a station was employed with a chamber measuring 1 m x 1 m x 1 m withequipment enabling the regulation of ammonia concentration and nozzle operating parameters,as well as an ammonia concentration measurement system. In the first part of the research, thespraying characteristics of selected spiral nozzles were determined at pressures of 2 bar and 3 bar.For selected nozzle operating parameters, ammonia absorption tests were carried out at variousinitial concentration values: 250 ppm, 500 ppm, 1000 ppm. Based on the collected results, thenozzle characteristic p(Q), the distribution of the nozzle spray intensity in the SUFER program, theammonia concentration curve as a function of water supply time and the absorption rate constantwere determined.
29 May 2023 in Archives of Environmental Protection
The article shows the effect of the supply pressure of fog nozzles on the process of ammonia sorption. In the tests, the nozzles flow characteristics Q=f(p) and the dependence of NH3 concentration as a function of the water stream feeding in time at different supply pressures were determined. For the TF 6 NN, TF 6 V, NF 15, CW 50 nozzles, measurements were carried out at the following supply pressures: 0.1 MPa; 0.2MPa; 0.3MPa; 0.4MPa; 0.5MPa. It was observed that the greatest effect of nozzle feed pressure on ammonia sorption efficiency may be expected at lower pressure values. At higher values, the sorption rate becomes stabilized and even starts to decrease. The decreases in the sorption rate constant observed for higher pressures may be due to a reduction contact time of the droplet and the achievement of the critical mixing rate of ammonia vapors in the air intensively saturated with water streams. This is due to diffusion rate limitations. The measurements show that the use of supply pressures for fog nozzles above 0.4 MPa is not justified. It should be noted that varying the feed pressure of nozzles of various designs can affect their ammonia sorption efficiency differently. The type of nozzle and supply pressure affects the distribution of droplets in space. The angle of dispersion and the shape of the generated jet have a critical influence on the efficiency of the sorption process. Complete filling of the space and a large spray angle assure relatively high sorption efficiency.
13 November 2023 in Zeszyty Naukowe Pro Publico Bono
24 June 2022 in Zeszyty Naukowe SGSP
28 December 2025 in Zeszyty Naukowe SGSP
The aim of the study was to analyse and compare air quality in exercise rooms located in selected FireStations in the Kuyavian-Pomeranian and Masovian provinces. Based on the conducted measurementsconcentrations of selected fractions of suspended particulate matter (PM2.5 and PM10) wereassessed in gym rooms in the selected Fire Stations. The study showed that the maximum permissibleconcentrations (MPC) in various types of firefighters’ exercise rooms have not been exceeded.Moreover, the analyses indicated that the key parameters influencing suspended particulateconcentration in the tested rooms include ventilation conditions, personnel movement, and thenature of the activities performed. The results obtained can be used in further research to assess thehealth risks faced by firefighters exposed to polluted air.