Ammar Alammar

Dr. Ammar Alammar

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Jamil BinabidJamil Binabid
Jamil Binabid
AAAbdulrahman Alymani
Abdulrahman Alymani
AAAmmar Alammar
Ammar Alammar
In hot, arid climates, educational buildings often face the challenge of limited outdoor space usage. This research, through comprehensive simulation, aims to propose practical solutions to enhance outdoor thermal comfort, particularly during school break times and student dismissal periods, thereby fostering more comfortable and functional outdoor school environments. That will happen through achieving the main objective of the study, which is evaluating the suggested passive strategies. Riyadh was selected as the case study, and four representative schools were analyzed through simulation and optimization processes to identify key areas for improvement. The research leveraged simulation tools such as Ladybug and Grasshopper in Rhino, highlighting the practicality and impact of this approach. Simulations were performed to assess the existing outdoor thermal conditions using the universal thermal climate index (UTCI) and to pinpoint regions with elevated thermal discomfort. Passive design interventions, such as shading devices and vegetation, were explored and optimized using the Galapagos in Grasshopper. This methodology supports the originality of this research in its integration of simulation tools, such as Ladybug and Grasshopper, with optimization techniques using the Galapagos plugin, specifically applied to the unique site-specific context of educational outdoor environments in a hot, dry climate in Riyadh. Additionally, insights for urban planners and architects demonstrate the possibility of integrating passive design principles to improve the usability and sustainability of outdoor spaces. The findings indicated that fewer apertures in shade devices combined with greater tree canopies might double the effectivity in lowering UTCI values, thereby enhancing thermal comfort, especially during peak summer months.

11 November 2026 in Energies
Verified
Journal Article
Open access
PDF file
AAAmmar Alammar
Ammar Alammar
Phase change material (PCM) envelopes store latent heat only if the material melts during the day and solidifies at night, and elevated urban night-time temperatures can prevent this regeneration. Adaptive thermal coupling has been proposed as a regeneration strategy, but it remains unclear when it delivers genuine latent-storage benefits rather than acting as dynamic insulation. This study identifies the thermal bounds of that operating window for an office building in four Saudi cities, representing hot-arid (Riyadh), hot-humid coastal (Jeddah and Dammam), and highland (Abha) climates, and three urban morphologies of low, medium, and high density. Morphology-specific weather files from the Urban Weather Generator drove 1524 EnergyPlus simulations of static PCM envelopes. These were followed by phase-state diagnostics, adaptive-coupling scenarios compared against inert-layer controls (identical layers without latent heat), and a cooling-setpoint sensitivity analysis. The annual recharge margin (the PCM solidification temperature minus the mean summer nightly minimum of the urban air temperature) alone did not predict adaptive performance. Instead, useful operation was bounded by a regeneration floor set by night-time conditions and an activation ceiling tied to the cooling setpoint. In the cases tested, the upper limit of useful melting temperatures was about 2 K above the setpoint, and melting temperatures below it were also effective. Three regimes emerged. Under sink-limited conditions, coupling increased PCM cycling without meaningful savings. Within the latent adaptive window, coupling reduced the monthly cooling supplied by a median of 3.5–3.8% relative to the static PCM envelope at margins of 0 to +1.5 K and by less than 1% at −1.5 to 0 K. Of this reduction, 82–87% was attributable to the PCM and its interaction with the control. In Abha with a 24 °C layer, the annual reduction was 3.4–6.0% relative to the static envelope and 4.9–10.0% relative to the wall without PCM. At higher recharge margins, the PCM contribution diminished, and dynamic insulation dominated. In the summers of the three hot cities (Riyadh, Jeddah and Dammam), the regeneration floor lay above the activation ceiling, so no tested melting temperature was effective; cooler months opened a seasonal window. The resulting empirical framework indicates, for the conditions examined, when adaptive PCM envelopes provide useful latent storage under given urban microclimates and operating conditions.

9 September 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Wassim JabiWassim Jabi
Wassim Jabi
AAAbdulrahman Alymani
Abdulrahman Alymani
AAAmmar Alammar
Ammar Alammar
In this paper, we introduce graph machine learning to enhance the estimation of heating and cooling loads in buildings, a critical factor in building energy efficiency. Traditional methods often overlook the complex interaction between building topology and geometric characteristics, leading to less accurate predictions. This research bridges this gap by incorporating these elements into a graph-based machine learning framework. This study introduces a parametric generative workflow to create a synthetic dataset, which is central to this research. This dataset encompasses multiple building forms, each with unique topological connections and attributes, ensuring a thorough analysis across varied building scenarios. The research involves simulating diverse building shapes and glazing scenarios with different window sizes and orientations. The study primarily utilizes Deep Graph Learning (DGL) for training, with Random Forest (RF) serving as a baseline for validation. Both DGL and RF algorithms demonstrate high performance in predicting heating and cooling loads.

6 October 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
AAAmmar Alammar
Ammar Alammar
AAAbdulrahman Alymani
Abdulrahman Alymani
MAMohammed Alsofiani
Mohammed Alsofiani
LMLibish Murugesan
Libish Murugesan
Eshrar LatifEshrar Latif
Eshrar Latif
Phase-change material (PCM) glazing and dynamic external shading are promoted as sustainable cooling measures, yet they act on the same solar load and are rarely assessed together under a mandatory energy code. This study aims to evaluate and compare the individual and combined performance of PCM glazing and adaptive external louvres in reducing cooling demand in a code-compliant office building under present and future hot–arid climates. The reference case is an SBC 601-compliant west-facing Riyadh office under present and 2080 weather. EnergyPlus was coupled with a calibrated one-dimensional enthalpy PCM model using a one-way coupling framework. The approach was verified against a fully bidirectional co-simulation (0.5–1.8%). Adaptive louvres cut annual cooling by 10.2% (71% of the west-glazing share). A matched no-latent control attributes only 0.5 of the 9.4 points saved by PCM glazing to latent storage: the code glazing optically starves the PCM. Their combination is sub-additive by 6.6 percentage points across 21 sensitivity variants. Melt and placement sweeps favour a 35 °C melt point and the outer pane. On thermal grounds, adaptive external louvres should be prioritised for code-compliant hot–arid buildings, while PCM glazing is most beneficial where higher solar gains allow latent heat utilisation, informing sustainable façade codes.