A single-input and single-output (SISO) frequencymodulated continuous wave (FMCW) radar architecture is proposed and in vivo demonstrated for remote two-dimensional (2-D) localization (range and angular information) and vital signs monitoring of multiple subjects. The radar sensor integrates two frequency scanning antennas which allow angular separation and enable determining a 2-D map (range vs. angle) of a room environment from which people can be distinguished from objects and clutter. After technical tests to validate the functionality of the proposed architecture and data processing algorithm, a practical setup was successfully demonstrated to locate human volunteers, at different absolute distances and orientations, and to retrieve their respiratory and heart rate information. Experimental results show that this radar sensor can monitor accurately the vital signs of multiple subjects within typical room settings, reporting maximum mean absolute errors of 0.747 breaths-perminute and 2.645 beats-per-minute respectively for respiration rate and heartbeat. Practical applications arise for Internet of Things (IoT), ambient assisted living, healthcare, geriatric and quarantine medicine, automotive, rescue and security purposes.
17 March 2021 in IEEE Transactions on Biomedical Engineering
Objective: Over the last two decades, radar-based contactless monitoring of vital signs (heartbeat and respiration rate) has raised increasing interest as an emerging and added value to health care. However, until now, the flaws caused by indoor multipath propagation formed a fundamental hurdle for the adoption of such technology in practical healthcare applications where reliability and robustness are crucial. Multipath reflections, originated from one person, combine with the direct signals and multipaths of other people and stationary objects, thus jeopardizing individual vital signs extraction and localization. This work focuses on tackling indoor multipath propagation. Methods: We describe a methodology, based on accurate models of the indoor multipaths and of the radar signals, that enables separating the undesired multipaths from desired signals of multiple individuals, removing a key obstacle to real-world contactless vital signs monitoring and localization. Results: We also demonstrated it by accurately measure individual heart rates, respiration rates, and absolute distances (range information) of paired volunteers in a challenging real-world office setting. Conclusion: The approach, validated using a frequency-modulated continuous wave (FMCW) radar, was shown to function in an indoor environment where radar signals are severely affected by multipath reflections. Significance: Practical applications arise for health care, assisted living, geriatric and quarantine medicine, rescue and security purposes.
28 January 2019 in IEEE Transactions on Biomedical Circuits and Systems
Electrocardiogram (ECG) is one of the major physiological vital signs and an effective monitoring method for patients with cardiovascular diseases. However, existing ECG recordings require a galvanic body contact, which is unpractical in daily life. This paper presents the design of an ECG chip that facilitates non-contact ECG recording through capacitive coupling. With the input impedance boosting techniques, as well as an active driven-right-leg (DRL) which boosts common-mode rejection ratio (CMRR) to 70 dB, the single-ended capacitive feedback active electrode (AE) achieves ultra-high input impedance of 400 GΩ (< 0.5 Hz), a large common-mode (CM) interference tolerance (2.8 Vpp), and a high linear-input-range (220 mVpp). Implemented in 0.18 μm 5V CMOS process, the prototype occupies an area of 1.23 mm2, and consumes 18 μA and 13 μA for the AE and DRL respectively. Real life non-contact capacitively coupled ECG acquisition has been demonstrated, obtaining ECG waves and heart rate in the presence of motion artifacts as well as ambient interference.
29 March 2017 in IEEE Transactions on Biomedical Circuits and Systems
A Doppler radar operating as a Phase-Locked-Loop (PLL) in frequency demodulator configuration is presented and discussed. The proposed radar presents a unique architecture, using a single channel mixer, and allows to detect contactless vital signs parameters while solving the null point issue and without requiring the small angle approximation condition. Spectral analysis, simulations, and experimental results are presented and detailed to demonstrate the feasibility and the operational principle of the proposed radar architecture.
A wireless pulse oximeter for non-invasive measurement of pulse and blood oxygen saturation has been realized. The device is powered by a thermoelectric generator in the form of a watch using the person's body heat and therefore achieves full energy autonomy. It does not require a battery, only a small (super-)capacitor as a short-time energy buffer. At 22degC ambient temperature, the generator produces more than 100muW of electrical power. All signal processing is done locally in the sensor. To our knowledge, this is the first realization of a non-trivial biomedical sensor fully powered by the patient's body heat.